PE and XLPE Insulated Aerial Bundle Cables | Low Voltage ABC
PE&XLPE Aerial Bundle Cables for Overhead Distribution Lines
PE & XLPE Aerial Bundle Cables Applications
Urban Distribution: Khususnya, this cable safely powers city streets and commercial zones.
Rural Networks: Sebagai tambahan, reka bentuk sut long-span lines across uneven terrain.
Roadside Facilities: Lebih-lebih lagi, it ensures reliable distribution along highways and public corridors.
Forested Regions: The robust insulation actively prevents faults caused by tree contact.
Grid Upgrades: Akibatnya, it efficiently upgrades old bare conductor lines to reduce power loss.
Coastal Areas: Akhirnya, the durable jacket withstands salt spray and high humidity.
- Pemprosesan Sampel Pantas dengan Penyelesaian Tersuai
- Bahan Berkualiti Tinggi
- Pilihan Harga Mampu Milik
- Penghantaran Global
- Untuk perlindungan data yang lebih baik, pastikan semua muat naik adalah selamat
Jimat sekurang-kurangnya 30% secara purata
-
Penerangan Produk
PE&XLPE Aerial Bundle Cables : Product Description and Specifications
LV Aerial Bundle Cable series (0.6/1 kV – 1.2 kV) for overhead distribution. The assembly utilizes AAAC atau Aluminium conductors helically stranded around a structural messenger. Insulation options include PE atau XLPE, functioning as a primary mechanical barrier and dielectric shield. Manufacturing protocols strictly adhere to IEC 60502-1 dan TNB standards to ensure grid reliability.
-
Kelebihan
PE&XLPE Aerial Bundle Cables : Benefits and Features
Environmental Endurance: Severe Climate Verified. Engineered to withstand extreme thermal cycling and environmental loads without degradation.
Flexibility Class: Stranded Copper Architecture. High-flex design optimizes bend radius for rapid, efficient routing.
Fire Behavior: Flame Retardant System. Insulation chemistry actively limits thermal propagation. Safety Result: Self-extinguishing properties.
UV Hardening: Solar Immunity. The outer sheath creates an impervious barrier against direct solar radiation, preventing long-term polymer breakdown.
Pematuhan: Global Certification. Verified adherence to CE and international Solar Energy standardet.
Specification Of PE&XLPE Aerial Bundle Cables
| Standard | Penerangan |
|---|---|
| IEC 60502-1 | Power Cables With Extruded Insulation And Their Accessories For Rated Voltages From 1 kV ( Um = 1.2 kV) Up To 30 kV ( Um = 36 kV). |
| TNB | Specification for Low Voltage Aerial Bundle Cable |
| AS/NZS 3560.1 | Electric cables – Cross-linked polyethylene insulated – Aerial bundled – For working voltage up to and including 0.6/1(1.2) kV |
| BS 7870-5 | Polymeric insulated aerial bundled conductors (ABC ) of rated voltage 0.6/1 kV for overhead distribution |
| DES/LV/ABC | Specification for Low Voltage Aerial Bundle Conductor (Aluminium ) |
| AS/NZS 3599.1 | Electric cables – Aerial bundled – Polymeric insulated – Voltages 6.35/11 (12) kV and 12.7/22 (24) kV |
| AS/NZS 3599.2 | Electric cables – Aerial bundled – Polymeric insulated – Voltages 6.35/11 (12) kV and 12.7/22 (24) kV |
Dimensi/Parameter
| Parameter | Unit | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 | 240 mm2 |
|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 50 | 70 | 95 | 120 | 150 | 185 | 240 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | 15 | 15 | 30 | 30 | |
| Nominal diameter of conductor | mm | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 | 18.4 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Metallic screening approx. thickness of copper tape | mm | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
| Nominal thickness of outer sheath | mm | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
| Nominal diameter over sheathing | mm | 23 | 24.6 | 26.3 | 27.8 | 29.2 | 30.9 | 33.3 |
| Max. dc resistance at 20°C | ohm/km | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 |
| Earth fault current capacity: -1 second (1 Core) | kA | 1.57 | 1.72 | 1.88 | 2.01 | 2.14 | 2.3 | 2.52 |
| Earth fault current capacity: -3 seconds (1 Core) | kA | 0.9 | 0.99 | 1.08 | 1.16 | 1.23 | 1.33 | 1.45 |
| Messenger: Nominal cross-sectional area | mm2 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Messenger: Stranding | No./mm | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 |
| Messenger: Direction of the outermost layer | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | |
| Messenger: Overall diameter | mm | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 |
| Messenger: Minimum breaking load | kg | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 |
| Completed cable: Approx. overall diameter | mm | 55 | 59 | 62 | 65 | 67 | 71 | 75 |
| Completed cable: Approx. weight of cable | kg/km | 2540 | 2890 | 3300 | 3660 | 4040 | 4540 | 5290 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| Parameter | Unit | 50 mm2 | 70 mm2 | 95 mm2 |
|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 50 | 70 | 95 |
| Number of cores | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | |
| Nominal insulation thickness | mm | 1.5 | 1.5 | 1.7 |
| Diameter of insulated core | mm | 11.5 | 13.2 | 15.3 |
| Max. dc resistance at 20°C | ohm/km | 0.641 | 0.443 | 0.32 |
| Current rating at still wind, ambient temp 30°C, conductor temp 75°C | A | 129 | 167 | 209 |
| Neutral conductor: Nominal cross-sectional area | mm2 | 50 | 70 | 95 |
| Minimum number of wires | 6 | 12 | 15 | |
| Nominal insulation thickness | mm | 1.5 | 1.5 | 1.7 |
| Diameter of insulated core | mm | 11.5 | 11.5 | 15.3 |
| Max. dc resistance at 20°C | ohm/km | 0.641 | 0.443 | 0.32 |
| Street lighting conductor: Nominal cross-sectional area | mm2 | 25 | 25 | 25 |
| Minimum number of wires | 6 | 6 | 6 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 |
| Diameter of insulated core | mm | 8.8 | 8.8 | 8.8 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 1.2 | 1.2 |
| Completed cable: Minimum breaking load | kN | 34.5 | 48.1 | 65.3 |
| Approx. overall diameter | mm | 29.8 | 33.6 | 38.2 |
| Approx. weight of cable | kg/km | 830 | 1100 | 1470 |
| Packing length | m/drum | 1000 | 1000 | 500 |
| Parameter | Unit | 25 mm2 | 35 mm2 |
|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 25 | 35 |
| Number of cores | 3 | 3 | |
| Minimum number of wires | 6 | 6 | |
| Nominal insulation thickness | mm | 1.4 | 1.4 |
| Diameter of insulated core | mm | 8.9 | 9.9 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 |
| Minimum breaking load | kN | 3.5 | 4.9 |
| Current rating at still wind, ambient temp 30°C, conductor temp 75°C | A | 84 | 104 |
| Neutral Conductor: Nominal cross-sectional area | mm2 | 25 | 35 |
| Minimum number of wires | 6 | 6 | |
| Nominal insulation thickness | mm | 1.4 | 1.4 |
| Diameter of insulated core | mm | 8.9 | 9.9 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 |
| Minimum breaking load | kN | 3.5 | 4.9 |
| Completed cable: Approx. overall diameter | mm | 21.5 | 23.9 |
| Approx. weight of cable | kg/km | 420 | 550 |
| Packing length | m/drum | 1000 | 1000 |
| Parameter | Unit | 25 mm2 | 35 mm2 | 50 mm2 | 70 mm2 | 95* mm2 | 120 mm2 | 150 mm2 | 185* mm2 |
|---|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
| Nominal insulation thickness | mm | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2 |
| Diameter of insulated core | mm | 8.5 | 9.5 | 11.2 | 13 | 15.1 | 16.6 | 18.4 | 20.6 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at still wind, ambient temp 30°C, conductor temp 75°C | A | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
| Maximum voltage drop | mV/A/m | 2.54 | 1.84 | 1.36 | 0.95 | 0.69 | 0.55 | 0.46 | 0.37 |
| Messenger conductor: Nominal cross-sectional area | mm2 | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
| Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
| Max. dc resistance at 20°C | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
| Calculated breaking load | kN | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
| Street lighting conductor: Nominal cross-sectional area | mm2 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | |
| Nominal insulation thickness | mm | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Diameter of insulated core | mm | 6.8 | 6.8 | 6.8 | 6.8 | 6.8 | 6.8 | 6.8 | 6.8 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 |
| Completed cable: Approx. overall diameter | mm | 23.2 | 25.6 | 30 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
| Approx. weight of cable | kg/km | 470 | 560 | 740 | 980 | 1330 | 1580 | 1940 | 2410 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
| Parameter | Unit | 120 mm2 | 185 mm2 |
|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 120 | 185 |
| Number of cores | 3 | 3 | |
| Minimum number of wires | 15 | 30 | |
| Nominal insulation thickness | mm | 1.7 | 2.2 |
| Diameter of insulated core | mm | 17 | 21 |
| Max. dc resistance at 20°C | ohm/km | 0.253 | 0.164 |
| Minimum breaking load | kN | 16.8 | 25.9 |
| Current rating at still wind, ambient temp 30°C, conductor temp 75°C | A | 246 | 332 |
| Neutral conductor: Nominal cross-sectional area | mm2 | 120 | 185 |
| Minimum number of wires | 15 | 30 | |
| Nominal insulation thickness | mm | 1.7 | 2.2 |
| Diameter of insulated core | mm | 17 | 21 |
| Max. dc resistance at 20°C | ohm/km | 0.253 | 0.164 |
| Minimum breaking load | kN | 16.8 | 25.9 |
| Street lighting conductor: Nominal cross-sectional area | mm2 | 25 | 25 |
| Minimum number of wires | 6 | 6 | |
| Nominal insulation thickness | mm | 1.4 | 1.4 |
| Diameter of insulated core | mm | 8.9 | 8.9 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 1.2 |
| Completed cable: Approx. overall diameter | mm | 43.8 | 50.7 |
| Approx. weight of cable | kg/km | 1800 | 2700 |
| Packing length | m/drum | 500 | 500 |
| Parameter | Unit | 25 mm2 (1c) | 35 mm2 (1c) | 50 mm2 (1c) | 70 mm2 (1c) | 95 mm2 (1c) | 25 mm2 (3c) | 35 mm2 (3c) | 50 mm2 (3c) | 70 mm2 (3c) | 95 mm2 (3c) | 120 mm2 (3c) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 25 | 35 | 50 | 70 | 95 | 25 | 35 | 50 | 70 | 95 | 120 |
| Number of cores | 1 | 1 | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 6 | 6 | 6 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.7 |
| Diameter of insulated core | mm | 8.8 | 9.8 | 11.5 | 13.2 | 15.3 | 8.8 | 9.8 | 11.5 | 13.2 | 15.3 | 16.8 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 |
| Current rating at still wind, ambient temp 30°C, conductor temp 75°C | A | 84 | 104 | 129 | 167 | 209 | 84 | 104 | 129 | 167 | 209 | 283 |
| Neutral conductor: Nominal cross-sectional area | mm2 | 25 | 35 | 50 | 70 | 95 | 25 | 35 | 50 | 70 | 95 | 120 |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 6 | 6 | 6 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.7 |
| Diameter of insulated core | mm | 8.8 | 9.8 | 11.5 | 13.2 | 15.3 | 8.8 | 9.8 | 11.5 | 13.2 | 15.3 | 16.8 |
| Max. dc resistance at 20°C | ohm/km | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 |
| Completed cable: Minimum breaking load | kN | 8.2 | 11.2 | 15.2 | 22 | 30.6 | 16.4 | 22.4 | 30.4 | 44 | 61.2 | 77.6 |
| Approx. overall diameter | mm | 17.6 | 19.6 | 23 | 26.4 | 30.6 | 21.2 | 23.7 | 27.8 | 31.9 | 36.9 | 40.6 |
| Approx. weight of cable | kg/km | 210 | 270 | 360 | 500 | 680 | 410 | 550 | 730 | 1000 | 1370 | 1690 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 1000 | 1000 | 1000 | 1000 | 500 | 500 |
| Parameter | Unit | 16* mm2 (1c) | 16* mm2 (3c) | 25 mm2 | 35 mm2 | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 16 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 1 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
| Nominal insulation thickness | mm | 1 | 1 | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2 |
| Diameter of insulated core | mm | 6.8 | 6.8 | 8.5 | 9.5 | 11.2 | 13 | 15.1 | 16.6 | 18.4 | 20.6 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at still wind, ambient temp 30°C, conductor temp 75°C | A | 61 | 61 | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
| Maximum voltage drop | mV/A/m | 4.67 | 4.05 | 2.54 | 1.84 | 1.36 | 0.95 | 0.69 | 0.55 | 0.46 | 0.37 |
| Messenger conductor: Nominal cross-sectional area | mm2 | 25 | 25 | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
| Diameter of insulated core | mm | 8.5 | 8.5 | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
| Max. dc resistance at 20°C | ohm/km | 1.312 | 1.312 | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
| Calculated breaking load | kN | 6.4 | 6.4 | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
| Completed cable: Approx. overall diameter | mm | 15.3 | 19 | 23.2 | 25.6 | 30 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
| Approx. weight of cable | kg/km | 160 | 290 | 400 | 500 | 680 | 920 | 1270 | 1510 | 1870 | 2340 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
| Parameter | Unit | 16 mm2 (1c) | 25 mm2 (1c) | 35 mm2 (1c) | 50 mm2 (1c) | 95 mm2 (1c) | 25 mm2 (2c) | 35 mm2 (2c) | 50 mm2 (2c) |
|---|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 16 | 25 | 35 | 50 | 95 | 25 | 35 | 50 |
| Number of cores | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | |
| Minimum number of wires | 6 | 6 | 6 | 6 | 15 | 6 | 6 | 6 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 | 1.5 | 1.7 | 1.3 | 1.3 | 1.5 |
| Diameter of insulated core | mm | 7.5 | 8.8 | 9.8 | 11.4 | 15.3 | 8.8 | 9.8 | 11.4 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.2 | 0.868 | 0.641 | 0.32 | 1.2 | 0.868 | 0.641 |
| Current rating for typical Australian installation conditions Conductor temp 80°C | A | 78 | 105 | 125 | 150 | 230 | 97 | 120 | 140 |
| Neutral conductor: Nominal cross-sectional area | mm2 | 16 | 25 | 35 | 50 | 95 | 25 | 35 | 50 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 15 | 6 | 6 | 6 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 | 1.5 | 1.7 | 1.3 | 1.3 | 1.5 |
| Diameter of insulated core | mm | 7.5 | 8.8 | 9.8 | 11.4 | 15.3 | 8.8 | 9.8 | 11.4 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.2 | 0.868 | 0.641 | 0.32 | 1.2 | 0.868 | 0.641 |
| Completed cable: Minimum breaking load | kN | 4.4 | 7 | 9.8 | 14.0 | 26.6 | 10.5 | 14.7 | 21 |
| Approx. overall diameter | mm | 15 | 17.6 | 19.6 | 22.8 | 30.6 | 19 | 21.1 | 24.6 |
| Approx. weight of cable | kg/km | 140 | 210 | 270 | 370 | 680 | 310 | 410 | 550 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 1000 | 1000 | 1000 |
| --- SECTION BREAK --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Parameter (3 CORE VARIANTS) | Unit | 16 mm2 | 25 mm2 | 35 mm2 | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 |
| Phase conductor: Nominal cross-sectional area | mm2 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.7 | 1.7 |
| Diameter of insulated core | mm | 7.5 | 8.8 | 9.8 | 11.4 | 13.2 | 15.3 | 16.8 | 18.2 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 |
| Current rating for typical Australian installation conditions Conductor temp 80°C | A | 74 | 97 | 120 | 140 | 175 | 215 | 250 | 280 |
| Neutral conductor: Nominal cross-sectional area | mm2 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.3 | 1.3 | 1.3 | 1.5 | 1.5 | 1.7 | 1.7 | 1.7 |
| Diameter of insulated core | mm | 7.5 | 8.8 | 9.8 | 11.4 | 13.2 | 15.3 | 16.8 | 18.2 |
| Max. dc resistance at 20°C | ohm/km | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 |
| Completed cable: Minimum breaking load | kN | 8.8 | 14.0 | 19.6 | 28 | 39.2 | 53.2 | 67.2 | 84 |
| Approx. overall diameter | mm | 18.1 | 21.2 | 23.7 | 27.5 | 31.9 | 36.9 | 40.6 | 43.9 |
| Approx. weight of cable | kg/km | 290 | 410 | 550 | 740 | 1000 | 1370 | 1690 | 2020 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 |
| Parameter | Unit | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 | 240 mm2 |
|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 50 | 70 | 95 | 120 | 150 | 185 | 240 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | 15 | 15 | 30 | 30 | |
| Nominal diameter of conductor | mm | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 | 18.4 |
| Nominal thickness of XLPE insulation | mm | 8 | 8 | 8 | 8 | 8 | 8 | 8 |
| Metallic screening approx. thickness of copper tape | mm | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
| Nominal thickness of outer sheath | mm | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
| Nominal diameter over sheathing | mm | 32.2 | 33.8 | 35.5 | 37 | 38.4 | 40.1 | 42.5 |
| Max. dc resistance at 20°C | ohm/km | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 |
| Earth fault current capacity: -1 second (1 Core) | kA | 2.41 | 2.56 | 2.72 | 2.86 | 2.99 | 3.14 | 3.36 |
| Earth fault current capacity: -3 seconds (1 Core) | kA | 1.39 | 1.48 | 1.57 | 1.65 | 1.72 | 1.81 | 1.94 |
| Messenger: Nominal cross-sectional area | mm2 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Messenger: Stranding | No./mm | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 |
| Messenger: Direction of the outermost layer | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | |
| Messenger: Overall diameter | mm | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 |
| Messenger: Minimum breaking load | kg | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 |
| Completed cable: Approx. overall diameter | mm | 73 | 76 | 79 | 82 | 84 | 87 | 91 |
| Completed cable: Approx. weight of cable | kg/km | 3980 | 4400 | 4880 | 5300 | 5740 | 6310 | 7160 |
| Packing length | m/drum | 500 | 500 | 500 | 250 | 250 | 250 | 250 |
| Parameter | Unit | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 | 240 mm2 |
|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 50 | 70 | 95 | 120 | 150 | 185 | 240 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | 15 | 15 | 30 | 30 | |
| Nominal diameter of conductor | mm | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 | 18.4 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Metallic screening approx. thickness of copper tape | mm | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
| Nominal thickness of outer sheath | mm | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
| Nominal diameter over sheathing | mm | 27.2 | 28.8 | 30.5 | 32 | 33.4 | 35.1 | 37.5 |
| Max. dc resistance at 20°C | ohm/km | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 |
| Earth fault current capacity: -1 second (1 Core) | kA | 1.96 | 2.11 | 2.26 | 2.4 | 2.53 | 2.68 | 2.9 |
| Earth fault current capacity: -3 seconds (1 Core) | kA | 1.13 | 1.21 | 1.31 | 1.38 | 1.46 | 1.55 | 1.67 |
| Messenger: Nominal cross-sectional area | mm2 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Messenger: Stranding | No./mm | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 | 7/3.15 |
| Messenger: Direction of the outermost layer | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | |
| Messenger: Overall diameter | mm | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 |
| Messenger: Minimum breaking load | kg | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 |
| Completed cable: Approx. overall diameter | mm | 64 | 67 | 70 | 73 | 75 | 78 | 83 |
| Completed cable: Approx. weight of cable | kg/km | 3150 | 3540 | 3980 | 4360 | 4770 | 5300 | 6100 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 250 | 250 |
| Parameter | Unit | 35 mm2 (Type A) | 35 mm2 (Type B) | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 |
|---|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 18 | 18 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| Metallic screening: No. and diameter of copper wire | no./mm | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 |
| Nominal thickness of outer sheath | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 | 1.9 | 2 | 2 |
| Nominal diameter over sheathing | mm | 28.4 | 28.4 | 29.3 | 30.9 | 32.8 | 34.3 | 35.9 | 37.6 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temperature = 30°C | A | 170 | 170 | 205 | 260 | 315 | 360 | 410 | 470 |
| Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/s | A | 150 | 150 | 185 | 230 | 280 | 320 | 365 | 415 |
| Earth fault current carrying capacity of metallic screen at -1 second | kA | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Messenger: Stranding (Galvanized steel wire) | No./mm | 7/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 |
| Messenger: Direction of the outermost layer | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | |
| Messenger: Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable: Approx. overall diameter | mm | 62.8 | 66.8 | 68.5 | 71.8 | 75.6 | 78.6 | 81.8 | 85.2 |
| Approx. weight of cable | kg/km | 2340 | 2640 | 2780 | 3100 | 3510 | 3850 | 4240 | 4710 |
| Packing length | m/drum | 500 | 500 | 500 | 250 | 250 | 250 | 250 | 250 |
| Parameter | Unit | 35 mm2 | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 |
|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 12 | 15 | 18 | 18 | 30 | |
| Nominal diameter of conductor | mm | 7 | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Nominal thickness of cross-linked screen layer | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| Nominal thickness of semi-conductive HDPE layer | mm | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/s | A | 165 | 195 | 245 | 295 | 340 | 385 | 440 |
| Messenger (AAAC 1120): Stranding | No./mm | 7/5.0 | 7/5.0 | 7/5.0 | 7/5.0 | 19/3.65 | 19/3.65 | 19/3.65 |
| Messenger: Direction of the outermost layer | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | |
| Messenger: Overall diameter | mm | 14.3 | 14.3 | 14.3 | 14.3 | 17.3 | 17.3 | 17.3 |
| Completed cable: Approx. overall diameter | mm | 60.6 | 61.9 | 65.1 | 68.6 | 74.6 | 77.4 | 80.8 |
| Approx. weight of cable | kg/km | 1890 | 2000 | 2300 | 2670 | 3160 | 3500 | 3950 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 250 | 250 | 250 |
| Parameter | Unit | 35 mm2 (Type A) | 35 mm2 (Type B) | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 |
|---|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 18 | 18 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| Metallic screening: No. and diameter of copper wire | no./mm | 40/0.85 | 40/0.85 | 23/1.35 | 32/1.35 | 38/1.35 | 38/1.35 | 38/1.35 | 38/1.35 |
| Nominal thickness of outer sheath | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 |
| Nominal diameter over sheathing | mm | 24.2 | 24.2 | 26.1 | 27.7 | 29.4 | 30.9 | 32.3 | 34.2 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temperature = 30°C | A | 185 | 185 | 210 | 260 | 315 | 365 | 415 | 475 |
| Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/s | A | 155 | 155 | 185 | 230 | 280 | 325 | 370 | 425 |
| Earth fault current carrying capacity of metallic screen at -1 second | kA | 3.3 | 3.3 | 4.8 | 6.8 | 8 | 8 | 8 | 8 |
| Messenger: Stranding (Galvanized steel wire) | No./mm | 7/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 |
| Messenger: Direction of the outermost layer | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | |
| Messenger: Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable: Approx. overall diameter | mm | 54.4 | 58.4 | 62.1 | 65.4 | 68.8 | 71.8 | 74.6 | 78.4 |
| Approx. weight of cable | kg/km | 2150 | 2440 | 2880 | 3540 | 4130 | 4440 | 4770 | 5240 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 250 | 250 |
| Parameter | Unit | 35 mm2 (Type A) | 35 mm2 (Type B) | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 |
|---|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 18 | 18 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| Metallic screening: No. and diameter of copper wire | no./mm | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 | 24/0.85 |
| Nominal thickness of outer sheath | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 |
| Nominal diameter over sheathing | mm | 24.2 | 24.2 | 25.1 | 26.7 | 28.4 | 29.9 | 31.3 | 33.2 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temperature = 30°C | A | 185 | 185 | 210 | 260 | 315 | 365 | 415 | 475 |
| Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/s | A | 155 | 155 | 185 | 230 | 280 | 325 | 370 | 425 |
| Earth fault current carrying capacity of metallic screen at -1 second | kA | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Messenger: Stranding (Galvanized steel wire) | No./mm | 7/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 |
| Messenger: Direction of the outermost layer | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | |
| Messenger: Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable: Approx. overall diameter | mm | 54.4 | 58.4 | 60.1 | 63.4 | 66.8 | 69.8 | 72.6 | 76.4 |
| Approx. weight of cable | kg/km | 1890 | 2190 | 2320 | 2610 | 2960 | 3260 | 3590 | 4060 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 250 | 250 |
| Parameter | Unit | 35 mm2 (Type A) | 35 mm2 (Type B) | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 |
|---|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 35 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 18 | 18 | 30 | |
| Nominal diameter of conductor | mm | 7 | 7 | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 | 5.5 |
| Minimum thickness of insulation screen | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| Metallic screening: No. and diameter of copper wire | no./mm | 40/0.85 | 40/0.85 | 23/1.35 | 32/1.35 | 38/1.35 | 38/1.35 | 38/1.35 | 38/1.35 |
| Nominal thickness of outer sheath | mm | 1.8 | 1.8 | 1.8 | 1.8 | 1.9 | 1.9 | 2 | 2 |
| Nominal diameter over sheathing | mm | 28.4 | 28.4 | 30.3 | 31.9 | 33.8 | 35.3 | 36.9 | 38.6 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temperature = 30°C | A | 170 | 170 | 205 | 260 | 315 | 360 | 410 | 470 |
| Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/s | A | 150 | 150 | 185 | 230 | 280 | 320 | 365 | 415 |
| Earth fault current carrying capacity of metallic screen at -1 second | kA | 3.3 | 3.3 | 4.8 | 6.8 | 8 | 8 | 8 | 8 |
| Messenger: Stranding (Galvanized steel wire) | No./mm | 7/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 | 19/2.0 |
| Messenger: Direction of the outermost layer | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | Right-hand (Z) | |
| Messenger: Overall diameter | mm | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Completed cable: Approx. overall diameter | mm | 62.8 | 66.8 | 70.5 | 73.8 | 77.6 | 80.6 | 83.8 | 87.2 |
| Approx. weight of cable | kg/km | 2600 | 2900 | 3350 | 4030 | 4680 | 5020 | 5410 | 5880 |
| Packing length | m/drum | 500 | 500 | 500 | 250 | 250 | 250 | 250 | 250 |
| Parameter | Unit | 35 mm2 | 50 mm2 | 70 mm2 | 95 mm2 | 120 mm2 | 150 mm2 | 185 mm2 |
|---|---|---|---|---|---|---|---|---|
| Phase conductor: Nominal cross-sectional area | mm2 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 12 | 15 | 18 | 18 | 30 | |
| Nominal diameter of conductor | mm | 7 | 8.1 | 9.7 | 11.5 | 12.9 | 14.3 | 16.1 |
| Minimum thickness of conductor screen | mm | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Nominal thickness of XLPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Nominal thickness of cross-linked screen layer | mm | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
| Nominal thickness of semi-conductive HDPE layer | mm | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
| Max. dc resistance at 20°C | ohm/km | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/s | A | 165 | 200 | 245 | 300 | 345 | 390 | 450 |
| Messenger (AAAC 1120): Stranding | No./mm | 7/5.0 | 7/5.0 | 7/5.0 | 7/5.0 | 19/3.65 | 19/3.65 | 19/3.65 |
| Messenger: Direction of the outermost layer | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | Righthand (Z) | |
| Messenger: Overall diameter | mm | 14.3 | 14.3 | 14.3 | 14.3 | 17.3 | 17.3 | 17.3 |
| Completed cable: Approx. overall diameter | mm | 52.2 | 53.5 | 56.7 | 60.2 | 66.2 | 69 | 72.4 |
| Approx. weight of cable | kg/km | 1470 | 1580 | 1850 | 2180 | 2640 | 2960 | 3380 |
| Packing length | m/drum | 500 | 500 | 500 | 500 | 500 | 500 | 250 |
-
Proses Pengeluaran Kabel Bundle Udara
Untuk memastikan kualiti unggul, JOCA beroperasi fully digitalized and automated production lines for aerial cables. Khususnya, aliran kerja komprehensif ini mbulesat conductor stranding, insulation covering, sheathing, and final quality inspection. Lebih-lebih lagi, sistem pintar pantau secara aktif setiap peringkat untuk memastikan prestasi yang stabil dan kualiti produk yang konsisten. Sebagai tambahan, kilang përdor advanced testing facilities, such as tensile testing, elongation testing, spark testing, and laser diameter control. Akibatnya, langkah-langkah yang ketat ini jaminan bahawa setiap kabel yang dihantar sangat memenuhi piawaian antarabangsa.
Pembungkusan Untuk Penghantaran
Untuk memenuhi pelbagai keperluan pengangkutan, terdapat banyak kaedah pembungkusan yang boleh digunakan.
Ada lagi soalan?
Q: Compliance Standards?
A: Strict Adherence: IEC 60502-1 dan TNB Specifications (Range: 0.6/1 kV – 1.2 kV).
Q: Conductor Composition?
A: Bahan: AAAC atau Aluminium. Geometri: Helically stranded around a messenger wire (Configuration dependent).
Q: Typical Application Zones?
A: Deployment: Urban grids, residential feeders, rural pole lines, and narrow-corridor easements.
Q: Why XLPE Insulation?
A: Material Physics: Chosen for superior thermal resistance (90°C), mechanical toughness, and long-term aging immunity compared to PVC.
S: Penilaian Voltan?
A: LV Class: 0.6/1 kV. (Verified for TNB requirements up to 1.2 kV).
Q: Coastal/Humid Environment?
A: Disahkan. PE/XLPE insulation offers inherent waterproofing dan saline corrosion resistance.
Q: Messenger Wire Configuration?
A: Optional. (Material: AAAC). Functions as the primary mechanical support structure when integrated.
Q: Replacement for Bare Conductors?
A: Operational Gain. Replaces bare wire to drastically reduce electrical fault rates and lower O&M (Operations & Maintenance) costs.
















