PE and XLPE Insulated Aerial Bundle Cables | Low Voltage ABC

用於架空配電線路的 PE&XLPE 空中束電纜

PE & XLPE Aerial Bundle Cables Applications

  • Urban Distribution: 具體來說, this cable safely powers city streets and commercial zones.

  • Rural Networks: 另外, 設計 suits long-span lines across uneven terrain.

  • Roadside Facilities: 而且, it 確保 reliable distribution along highways and public corridors.

  • Forested Regions: The robust insulation actively prevents faults caused by tree contact.

  • Grid Upgrades: 因此, it efficiently upgrades old bare conductor lines to reduce power loss.

  • Coastal Areas: Finally, the durable jacket withstands salt spray and high humidity.

 平均至少節省 30%

PE and XLPE Insulated Aerial Bundle Cables_1
  • 圖示

    產品說明

    PE&XLPE Aerial Bundle Cables : Product Description and Specifications

LV Aerial Bundle Cable series (0.6/1 kV – 1.2 kV) for overhead distribution. The assembly utilizes AAAC 或者 conductors helically stranded around a structural messenger. Insulation options include 聚乙烯 或者 XLPE, functioning as a primary mechanical barrier and dielectric shield. Manufacturing protocols strictly adhere to IEC 60502-1TNB standards to ensure grid reliability.

PE 和 XLPE 絕緣空中束電纜
  • 圖示

    優點

    PE&XLPE Aerial Bundle Cables : Benefits and Features

  • Environmental Endurance: Severe Climate Verified. Engineered to withstand extreme thermal cycling and environmental loads without degradation.

  • Flexibility Class: Stranded Copper Architecture. High-flex design optimizes bend radius for rapid, efficient routing.

  • Fire Behavior: Flame Retardant System. Insulation chemistry actively limits thermal propagation. Safety Result: Self-extinguishing properties.

  • UV Hardening: Solar Immunity. The outer sheath creates an impervious barrier against direct solar radiation, preventing long-term polymer breakdown.

  • 合規性: Global Certification. Verified adherence to CE and international Solar Energy 標準。.

Specification Of PE&XLPE Aerial Bundle Cables

標準描述
IEC 60502-1Power Cables With Extruded Insulation And Their Accessories For Rated Voltages From 1 kV ( Um = 1.2 kV) Up To 30 kV ( Um = 36 kV).
TNBSpecification for Low Voltage Aerial Bundle Cable
AS/NZS 3560.1Electric cables – Cross-linked polyethylene insulated – Aerial bundled – For working voltage up to and including 0.6/1(1.2) kV
BS 7870-5Polymeric insulated aerial bundled conductors (ABC ) of rated voltage 0.6/1 kV for overhead distribution
DES/LV/ABCSpecification for Low Voltage Aerial Bundle Conductor (Aluminium )
AS/NZS 3599.1Electric cables – Aerial bundled – Polymeric insulated – Voltages 6.35/11 (12) kV and 12.7/22 (24) kV
AS/NZS 3599.2Electric cables – Aerial bundled – Polymeric insulated – Voltages 6.35/11 (12) kV and 12.7/22 (24) kV

尺寸/參數

IEC 60502 & TNB Specifcation(0.6/1 (1.2) kV)Cables without street lighting
參數Unit50 mm270 mm295 mm2120 mm2150 mm2185 mm2240 mm2
Phase conductor: Nominal cross-sectional areamm2507095120150185240
Number of cores3333333
Minimum number of wires6121515153030
Nominal diameter of conductor毫米8.19.711.512.914.316.118.4
Nominal thickness of XLPE insulation毫米3.43.43.43.43.43.43.4
Metallic screening approx. thickness of copper tape毫米0.20.20.20.20.20.20.2
Nominal thickness of outer sheath毫米2.32.32.32.32.32.32.3
Nominal diameter over sheathing毫米2324.626.327.829.230.933.3
Max. dc resistance at 20°Cohm/km0.6410.4430.320.2530.2060.1640.125
Earth fault current capacity: -1 second (1 Core)kA1.571.721.882.012.142.32.52
Earth fault current capacity: -3 seconds (1 Core)kA0.90.991.081.161.231.331.45
Messenger: Nominal cross-sectional areamm250505050505050
Messenger: Stranding否/毫米7/3.157/3.157/3.157/3.157/3.157/3.157/3.15
Messenger: Direction of the outermost layerRighthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)
Messenger: Overall diameter毫米9.459.459.459.459.459.459.45
Messenger: Minimum breaking loadkg6270627062706270627062706270
Completed cable: Approx. overall diameter毫米55596265677175
Completed cable: Approx. weight of cable公斤/公里2540289033003660404045405290
Packing lengthm/drum500500500500500500500
IEC 60502 & TNB Specifcation(0.6/1 (1.2) kV)Cables with street lighting
參數Unit50 mm270 mm295 mm2
Phase conductor: Nominal cross-sectional areamm2507095
Number of cores333
Minimum number of wires61215
Nominal insulation thickness毫米1.51.51.7
Diameter of insulated core毫米11.513.215.3
Max. dc resistance at 20°Cohm/km0.6410.4430.32
Current rating at still wind, ambient temp 30°C, conductor temp 75°CA129167209
Neutral conductor: Nominal cross-sectional areamm2507095
Minimum number of wires61215
Nominal insulation thickness毫米1.51.51.7
Diameter of insulated core毫米11.511.515.3
Max. dc resistance at 20°Cohm/km0.6410.4430.32
Street lighting conductor: Nominal cross-sectional areamm2252525
Minimum number of wires666
Nominal insulation thickness毫米1.31.31.3
Diameter of insulated core毫米8.88.88.8
Max. dc resistance at 20°Cohm/km1.21.21.2
Completed cable: Minimum breaking loadkN34.548.165.3
Approx. overall diameter毫米29.833.638.2
Approx. weight of cable公斤/公里83011001470
Packing lengthm/drum10001000500
AL/XLPE INSULATED AERIAL BUNDLED CABLES AS/NZS 3560.1 0.6/1 (1.2) kV
參數Unit25 mm235 mm2
Phase conductor: Nominal cross-sectional areamm22535
Number of cores33
Minimum number of wires66
Nominal insulation thickness毫米1.41.4
Diameter of insulated core毫米8.99.9
Max. dc resistance at 20°Cohm/km1.20.868
Minimum breaking loadkN3.54.9
Current rating at still wind, ambient temp 30°C, conductor temp 75°CA84104
Neutral Conductor: Nominal cross-sectional areamm22535
Minimum number of wires66
Nominal insulation thickness毫米1.41.4
Diameter of insulated core毫米8.99.9
Max. dc resistance at 20°Cohm/km1.20.868
Minimum breaking loadkN3.54.9
Completed cable: Approx. overall diameter毫米21.523.9
Approx. weight of cable公斤/公里420550
Packing lengthm/drum10001000
BS 7870-5 0.6/1 (1.2) kV Cables without street lighting
參數Unit25 mm235 mm250 mm270 mm295* mm2120 mm2150 mm2185* mm2
Phase conductor: Nominal cross-sectional areamm22535507095120150185
Number of cores33333333
Minimum number of wires6661215153030
Nominal insulation thickness毫米1.21.21.41.41.61.61.82
Diameter of insulated core毫米8.59.511.21315.116.618.420.6
Max. dc resistance at 20°Cohm/km1.20.8680.6410.4430.320.2530.2060.164
Current rating at still wind, ambient temp 30°C, conductor temp 75°CA84104129167209246283332
Maximum voltage dropmV/A/m2.541.841.360.950.690.550.460.37
Messenger conductor: Nominal cross-sectional areamm225253550707095120
Minimum number of wires666612121515
Nominal insulation thickness毫米1.21.21.21.41.41.41.61.6
Diameter of insulated core毫米8.58.59.511.213.113.115.116.6
Max. dc resistance at 20°Cohm/km1.3121.3120.9430.6930.4690.4690.3490.273
Calculated breaking loadkN6.46.48.912.118.018.024.230.8
Street lighting conductor: Nominal cross-sectional areamm21616161616161616
Minimum number of wires66666666
Nominal insulation thickness毫米11111111
Diameter of insulated core毫米6.86.86.86.86.86.86.86.8
Max. dc resistance at 20°Cohm/km1.911.911.911.911.911.911.911.91
Completed cable: Approx. overall diameter毫米23.225.63034.940.644.149.254.9
Approx. weight of cable公斤/公里4705607409801330158019402410
Packing lengthm/drum1000100010001000500500500500
BS 7870-5 0.6/1 (1.2) kV Cables without street lighting Cables with street lighting
參數Unit120 mm2185 mm2
Phase conductor: Nominal cross-sectional areamm2120185
Number of cores33
Minimum number of wires1530
Nominal insulation thickness毫米1.72.2
Diameter of insulated core毫米1721
Max. dc resistance at 20°Cohm/km0.2530.164
Minimum breaking loadkN16.825.9
Current rating at still wind, ambient temp 30°C, conductor temp 75°CA246332
Neutral conductor: Nominal cross-sectional areamm2120185
Minimum number of wires1530
Nominal insulation thickness毫米1.72.2
Diameter of insulated core毫米1721
Max. dc resistance at 20°Cohm/km0.2530.164
Minimum breaking loadkN16.825.9
Street lighting conductor: Nominal cross-sectional areamm22525
Minimum number of wires66
Nominal insulation thickness毫米1.41.4
Diameter of insulated core毫米8.98.9
Max. dc resistance at 20°Cohm/km1.21.2
Completed cable: Approx. overall diameter毫米43.850.7
Approx. weight of cable公斤/公里18002700
Packing lengthm/drum500500
IEC 60502 & DES/LV/ABC 0.6/1 (1.2) kV Cables without street lighting
參數Unit25 mm2 (1c)35 mm2 (1c)50 mm2 (1c)70 mm2 (1c)95 mm2 (1c)25 mm2 (3c)35 mm2 (3c)50 mm2 (3c)70 mm2 (3c)95 mm2 (3c)120 mm2 (3c)
Phase conductor: Nominal cross-sectional areamm225355070952535507095120
Number of cores11111333333
Minimum number of wires6661215666121515
Nominal insulation thickness毫米1.31.31.51.51.71.31.31.51.51.71.7
Diameter of insulated core毫米8.89.811.513.215.38.89.811.513.215.316.8
Max. dc resistance at 20°Cohm/km1.20.8680.6410.4430.321.20.8680.6410.4430.320.253
Current rating at still wind, ambient temp 30°C, conductor temp 75°CA8410412916720984104129167209283
Neutral conductor: Nominal cross-sectional areamm225355070952535507095120
Minimum number of wires6661215666121515
Nominal insulation thickness毫米1.31.31.51.51.71.31.31.51.51.71.7
Diameter of insulated core毫米8.89.811.513.215.38.89.811.513.215.316.8
Max. dc resistance at 20°Cohm/km1.20.8680.6410.4430.321.20.8680.6410.4430.320.253
Completed cable: Minimum breaking loadkN8.211.215.22230.616.422.430.44461.277.6
Approx. overall diameter毫米17.619.62326.430.621.223.727.831.936.940.6
Approx. weight of cable公斤/公里210270360500680410550730100013701690
Packing lengthm/drum10001000100010005001000100010001000500500
IEC 60502 & DES/LV/ABC 0.6/1 (1.2) kV Cables with street lighting
參數Unit16* mm2 (1c)16* mm2 (3c)25 mm235 mm250 mm270 mm295 mm2120 mm2150 mm2185 mm2
Phase conductor: Nominal cross-sectional areamm216162535507095120150185
Number of cores1333333333
Minimum number of wires666661215153030
Nominal insulation thickness毫米111.21.21.41.41.61.61.82
Diameter of insulated core毫米6.86.88.59.511.21315.116.618.420.6
Max. dc resistance at 20°Cohm/km1.911.911.20.8680.6410.4430.320.2530.2060.164
Current rating at still wind, ambient temp 30°C, conductor temp 75°CA616184104129167209246283332
Maximum voltage dropmV/A/m4.674.052.541.841.360.950.690.550.460.37
Messenger conductor: Nominal cross-sectional areamm2252525253550707095120
Minimum number of wires66666612121515
Nominal insulation thickness毫米1.21.21.21.21.21.41.41.41.61.6
Diameter of insulated core毫米8.58.58.58.59.511.213.113.115.116.6
Max. dc resistance at 20°Cohm/km1.3121.3121.3121.3120.9430.6930.4690.4690.3490.273
Calculated breaking loadkN6.46.46.46.48.912.118.018.024.230.8
Completed cable: Approx. overall diameter毫米15.31923.225.63034.940.644.149.254.9
Approx. weight of cable公斤/公里1602904005006809201270151018702340
Packing lengthm/drum100010001000100010001000500500500500
6.35/11 (12) kV Specification: AL/XLPE/SCT/PVC Aerial Bundled Cables
參數Unit16 mm2 (1c)25 mm2 (1c)35 mm2 (1c)50 mm2 (1c)95 mm2 (1c)25 mm2 (2c)35 mm2 (2c)50 mm2 (2c)
Phase conductor: Nominal cross-sectional areamm21625355095253550
Number of cores11111222
Minimum number of wires666615666
Nominal insulation thickness毫米1.31.31.31.51.71.31.31.5
Diameter of insulated core毫米7.58.89.811.415.38.89.811.4
Max. dc resistance at 20°Cohm/km1.911.20.8680.6410.321.20.8680.641
Current rating for typical Australian installation conditions Conductor temp 80°CA7810512515023097120140
Neutral conductor: Nominal cross-sectional areamm21625355095253550
Minimum number of wires666615666
Nominal insulation thickness毫米1.31.31.31.51.71.31.31.5
Diameter of insulated core毫米7.58.89.811.415.38.89.811.4
Max. dc resistance at 20°Cohm/km1.911.20.8680.6410.321.20.8680.641
Completed cable: Minimum breaking loadkN4.479.814.026.610.514.721
Approx. overall diameter毫米1517.619.622.830.61921.124.6
Approx. weight of cable公斤/公里140210270370680310410550
Packing lengthm/drum1000100010001000500100010001000
--- SECTION BREAK ------------------------------
Parameter (3 CORE VARIANTS)Unit16 mm225 mm235 mm250 mm270 mm295 mm2120 mm2150 mm2
Phase conductor: Nominal cross-sectional areamm2162535507095120150
Number of cores33333333
Minimum number of wires666612151515
Nominal insulation thickness毫米1.31.31.31.51.51.71.71.7
Diameter of insulated core毫米7.58.89.811.413.215.316.818.2
Max. dc resistance at 20°Cohm/km1.911.20.8680.6410.4430.320.2530.206
Current rating for typical Australian installation conditions Conductor temp 80°CA7497120140175215250280
Neutral conductor: Nominal cross-sectional areamm2162535507095120150
Minimum number of wires666612151515
Nominal insulation thickness毫米1.31.31.31.51.51.71.71.7
Diameter of insulated core毫米7.58.89.811.413.215.316.818.2
Max. dc resistance at 20°Cohm/km1.911.20.8680.6410.4430.320.2530.206
Completed cable: Minimum breaking loadkN8.814.019.62839.253.267.284
Approx. overall diameter毫米18.121.223.727.531.936.940.643.9
Approx. weight of cable公斤/公里2904105507401000137016902020
Packing lengthm/drum10001000100010001000500500500
IEC 60502 & TNB Standard: 12.7/22 (24) kV Cable Configuration
參數Unit50 mm270 mm295 mm2120 mm2150 mm2185 mm2240 mm2
Phase conductor: Nominal cross-sectional areamm2507095120150185240
Number of cores3333333
Minimum number of wires6121515153030
Nominal diameter of conductor毫米8.19.711.512.914.316.118.4
Nominal thickness of XLPE insulation毫米8888888
Metallic screening approx. thickness of copper tape毫米0.20.20.20.20.20.20.2
Nominal thickness of outer sheath毫米2.32.32.32.32.32.32.3
Nominal diameter over sheathing毫米32.233.835.53738.440.142.5
Max. dc resistance at 20°Cohm/km0.6410.4430.320.2530.2060.1640.125
Earth fault current capacity: -1 second (1 Core)kA2.412.562.722.862.993.143.36
Earth fault current capacity: -3 seconds (1 Core)kA1.391.481.571.651.721.811.94
Messenger: Nominal cross-sectional areamm250505050505050
Messenger: Stranding否/毫米7/3.157/3.157/3.157/3.157/3.157/3.157/3.15
Messenger: Direction of the outermost layerRighthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)
Messenger: Overall diameter毫米9.459.459.459.459.459.459.45
Messenger: Minimum breaking loadkg6270627062706270627062706270
Completed cable: Approx. overall diameter毫米73767982848791
Completed cable: Approx. weight of cable公斤/公里3980440048805300574063107160
Packing lengthm/drum500500500250250250250
High Voltage 19/33 (36) kV: Aerial Bundled Cable Technical Data
參數Unit50 mm270 mm295 mm2120 mm2150 mm2185 mm2240 mm2
Phase conductor: Nominal cross-sectional areamm2507095120150185240
Number of cores3333333
Minimum number of wires6121515153030
Nominal diameter of conductor毫米8.19.711.512.914.316.118.4
Nominal thickness of XLPE insulation毫米5.55.55.55.55.55.55.5
Metallic screening approx. thickness of copper tape毫米0.20.20.20.20.20.20.2
Nominal thickness of outer sheath毫米2.32.32.32.32.32.32.3
Nominal diameter over sheathing毫米27.228.830.53233.435.137.5
Max. dc resistance at 20°Cohm/km0.6410.4430.320.2530.2060.1640.125
Earth fault current capacity: -1 second (1 Core)kA1.962.112.262.42.532.682.9
Earth fault current capacity: -3 seconds (1 Core)kA1.131.211.311.381.461.551.67
Messenger: Nominal cross-sectional areamm250505050505050
Messenger: Stranding否/毫米7/3.157/3.157/3.157/3.157/3.157/3.157/3.15
Messenger: Direction of the outermost layerRighthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)
Messenger: Overall diameter毫米9.459.459.459.459.459.459.45
Messenger: Minimum breaking loadkg6270627062706270627062706270
Completed cable: Approx. overall diameter毫米64677073757883
Completed cable: Approx. weight of cable公斤/公里3150354039804360477053006100
Packing lengthm/drum500500500500500250250
Light Duty Screen: AL/XLPE/SCW/HDPE Cable (6.35/11 kV)
參數Unit35 mm2 (Type A)35 mm2 (Type B)50 mm270 mm295 mm2120 mm2150 mm2185 mm2
Phase conductor: Nominal cross-sectional areamm23535507095120150185
Number of cores33333333
Minimum number of wires6661215181830
Nominal diameter of conductor毫米778.19.711.512.914.316.1
Minimum thickness of conductor screen毫米0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulation毫米5.55.55.55.55.55.55.55.5
Minimum thickness of insulation screen毫米0.60.60.60.60.60.60.60.6
Metallic screening: No. and diameter of copper wireno./mm24/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.85
Nominal thickness of outer sheath毫米1.81.81.81.81.91.922
Nominal diameter over sheathing毫米28.428.429.330.932.834.335.937.6
Max. dc resistance at 20°Cohm/km0.8680.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temperature = 30°CA170170205260315360410470
Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/sA150150185230280320365415
Earth fault current carrying capacity of metallic screen at -1 secondkA22222222
Messenger: Stranding (Galvanized steel wire)否/毫米7/2.019/2.019/2.019/2.019/2.019/2.019/2.019/2.0
Messenger: Direction of the outermost layerRighthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)
Messenger: Overall diameter毫米610101010101010
Completed cable: Approx. overall diameter毫米62.866.868.571.875.678.681.885.2
Approx. weight of cable公斤/公里23402640278031003510385042404710
Packing lengthm/drum500500500250250250250250
Heavy Duty Screen Variant: 6.35/11 kV Aerial Cable
參數Unit35 mm250 mm270 mm295 mm2120 mm2150 mm2185 mm2
Phase conductor: Nominal cross-sectional areamm235507095120150185
Number of cores3333333
Minimum number of wires661215181830
Nominal diameter of conductor毫米78.19.711.512.914.316.1
Minimum thickness of conductor screen毫米0.30.30.30.30.30.30.3
Nominal thickness of XLPE insulation毫米5.55.55.55.55.55.55.5
Nominal thickness of cross-linked screen layer毫米0.60.60.60.60.60.60.6
Nominal thickness of semi-conductive HDPE layer毫米1.21.21.21.21.21.21.2
Max. dc resistance at 20°Cohm/km0.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/sA165195245295340385440
Messenger (AAAC 1120): Stranding否/毫米7/5.07/5.07/5.07/5.019/3.6519/3.6519/3.65
Messenger: Direction of the outermost layerRight-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)
Messenger: Overall diameter毫米14.314.314.314.317.317.317.3
Completed cable: Approx. overall diameter毫米60.661.965.168.674.677.480.8
Approx. weight of cable公斤/公里1890200023002670316035003950
Packing lengthm/drum500500500500250250250
12.7/22 (24) kV Configuration: Light Duty Screen (AS/NZS 3599.1)
參數Unit35 mm2 (Type A)35 mm2 (Type B)50 mm270 mm295 mm2120 mm2150 mm2185 mm2
Phase conductor: Nominal cross-sectional areamm23535507095120150185
Number of cores33333333
Minimum number of wires6661215181830
Nominal diameter of conductor毫米778.19.711.512.914.316.1
Minimum thickness of conductor screen毫米0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulation毫米3.43.43.43.43.43.43.43.4
Minimum thickness of insulation screen毫米0.60.60.60.60.60.60.60.6
Metallic screening: No. and diameter of copper wireno./mm40/0.8540/0.8523/1.3532/1.3538/1.3538/1.3538/1.3538/1.35
Nominal thickness of outer sheath毫米1.81.81.81.81.81.81.81.9
Nominal diameter over sheathing毫米24.224.226.127.729.430.932.334.2
Max. dc resistance at 20°Cohm/km0.8680.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temperature = 30°CA185185210260315365415475
Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/sA155155185230280325370425
Earth fault current carrying capacity of metallic screen at -1 secondkA3.33.34.86.88888
Messenger: Stranding (Galvanized steel wire)否/毫米7/2.019/2.019/2.019/2.019/2.019/2.019/2.019/2.0
Messenger: Direction of the outermost layerRight-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)
Messenger: Overall diameter毫米610101010101010
Completed cable: Approx. overall diameter毫米54.458.462.165.468.871.874.678.4
Approx. weight of cable公斤/公里21502440288035404130444047705240
Packing lengthm/drum500500500500500500250250
AS/NZS 3599.1 Standard: 12.7/22 kV Heavy Duty Screen Cable
參數Unit35 mm2 (Type A)35 mm2 (Type B)50 mm270 mm295 mm2120 mm2150 mm2185 mm2
Phase conductor: Nominal cross-sectional areamm23535507095120150185
Number of cores33333333
Minimum number of wires6661215181830
Nominal diameter of conductor毫米778.19.711.512.914.316.1
Minimum thickness of conductor screen毫米0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulation毫米3.43.43.43.43.43.43.43.4
Minimum thickness of insulation screen毫米0.60.60.60.60.60.60.60.6
Metallic screening: No. and diameter of copper wireno./mm24/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.8524/0.85
Nominal thickness of outer sheath毫米1.81.81.81.81.81.81.81.9
Nominal diameter over sheathing毫米24.224.225.126.728.429.931.333.2
Max. dc resistance at 20°Cohm/km0.8680.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temperature = 30°CA185185210260315365415475
Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/sA155155185230280325370425
Earth fault current carrying capacity of metallic screen at -1 secondkA22222222
Messenger: Stranding (Galvanized steel wire)否/毫米7/2.019/2.019/2.019/2.019/2.019/2.019/2.019/2.0
Messenger: Direction of the outermost layerRighthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)
Messenger: Overall diameter毫米610101010101010
Completed cable: Approx. overall diameter毫米54.458.460.163.466.869.872.676.4
Approx. weight of cable公斤/公里18902190232026102960326035904060
Packing lengthm/drum500500500500500500250250
AERIAL BUNDLED CABLES AL/XLPE/HDPE AS/NZS 3599.2 6.35/11 (12) kV
參數Unit35 mm2 (Type A)35 mm2 (Type B)50 mm270 mm295 mm2120 mm2150 mm2185 mm2
Phase conductor: Nominal cross-sectional areamm23535507095120150185
Number of cores33333333
Minimum number of wires6661215181830
Nominal diameter of conductor毫米778.19.711.512.914.316.1
Minimum thickness of conductor screen毫米0.30.30.30.30.30.30.30.3
Nominal thickness of XLPE insulation毫米5.55.55.55.55.55.55.55.5
Minimum thickness of insulation screen毫米0.60.60.60.60.60.60.60.6
Metallic screening: No. and diameter of copper wireno./mm40/0.8540/0.8523/1.3532/1.3538/1.3538/1.3538/1.3538/1.35
Nominal thickness of outer sheath毫米1.81.81.81.81.91.922
Nominal diameter over sheathing毫米28.428.430.331.933.835.336.938.6
Max. dc resistance at 20°Cohm/km0.8680.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temperature = 30°CA170170205260315360410470
Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/sA150150185230280320365415
Earth fault current carrying capacity of metallic screen at -1 secondkA3.33.34.86.88888
Messenger: Stranding (Galvanized steel wire)否/毫米7/2.019/2.019/2.019/2.019/2.019/2.019/2.019/2.0
Messenger: Direction of the outermost layerRight-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)Right-hand (Z)
Messenger: Overall diameter毫米610101010101010
Completed cable: Approx. overall diameter毫米62.866.870.573.877.680.683.887.2
Approx. weight of cable公斤/公里26002900335040304680502054105880
Packing lengthm/drum500500500250250250250250
AERIAL BUNDLED CABLES AL/XLPE/HDPE AS/NZS 3599.2 12.7/22 (24) kV
參數Unit35 mm250 mm270 mm295 mm2120 mm2150 mm2185 mm2
Phase conductor: Nominal cross-sectional areamm235507095120150185
Number of cores3333333
Minimum number of wires661215181830
Nominal diameter of conductor毫米78.19.711.512.914.316.1
Minimum thickness of conductor screen毫米0.30.30.30.30.30.30.3
Nominal thickness of XLPE insulation毫米3.43.43.43.43.43.43.4
Nominal thickness of cross-linked screen layer毫米0.60.60.60.60.60.60.6
Nominal thickness of semi-conductive HDPE layer毫米1.21.21.21.21.21.21.2
Max. dc resistance at 20°Cohm/km0.8680.6410.4430.320.2530.2060.164
Current rating at Ambient temp = 40°C, Solar = 1000W/m2, Wind = 1m/sA165200245300345390450
Messenger (AAAC 1120): Stranding否/毫米7/5.07/5.07/5.07/5.019/3.6519/3.6519/3.65
Messenger: Direction of the outermost layerRighthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)Righthand (Z)
Messenger: Overall diameter毫米14.314.314.314.317.317.317.3
Completed cable: Approx. overall diameter毫米52.253.556.760.266.26972.4
Approx. weight of cable公斤/公里1470158018502180264029603380
Packing lengthm/drum500500500500500500250
  • 圖示

    Production Processes Of Aerial Bundled Cable

確保卓越的品質, ,喬卡 經營 fully digitalized and automated production lines for aerial cables. 具體來說, ,這個綜合的工作流程 覆蓋 conductor stranding, insulation covering, sheathing, and final quality inspection. 而且, ,智能係統 主動監控 每個階段都確保穩定的性能和一致的產品品質。. 另外, ,工廠 利用 advanced testing facilities, such as tensile testing, elongation testing, spark testing, and laser diameter control. 因此, ,這些嚴格的措施 保證 每條交付的電纜都嚴格符合國際標準。.

光伏電線的生產流程

裝運包裝

為了滿足各種運輸需求,可以使用多種包裝方法。.

裝運包裝

還有更多問題嗎?

我們已在下面編制了有關規範、安全標準和應用程式的最常見問題。如果您沒有看到您正在尋找的內容,或沒有特定的自訂要求,只需直接聯絡我們的工程團隊即可。.

Q: Compliance Standards?

答: Strict Adherence: IEC 60502-1TNB Specifications (Range: 0.6/1 kV – 1.2 kV).

 

Q: Conductor Composition?

答: 材質: AAAC 或者 . Geometry: Helically stranded around a messenger wire (Configuration dependent).

 

Q: Typical Application Zones?

 答: Deployment: Urban grids, residential feeders, rural pole lines, and narrow-corridor easements.

 

Q: Why XLPE Insulation?

答: Material Physics: Chosen for superior thermal resistance (90°C), mechanical toughness, and long-term aging immunity compared to PVC.

Q:額定電壓?

答: LV Class: 0.6/1 kV. (Verified for TNB requirements up to 1.2 kV).

 

Q: Coastal/Humid Environment?

答: 已驗證。. PE/XLPE insulation offers inherent waterproofingsaline corrosion resistance.

 

Q: Messenger Wire Configuration?

答: Optional. (Material: AAAC). Functions as the primary mechanical support structure when integrated.

 

Q: Replacement for Bare Conductors?

答: Operational Gain. Replaces bare wire to drastically reduce electrical fault rates and lower O&M (Operations & Maintenance) costs.

滾動到頂部
與 JOCA 公司取得聯繫

請填寫下面的表格與我們聯繫。我們的目標是在 12 小時內回覆您。祝您一切順利!

聯絡表格演示

喬卡