NYCY / NAYCY
0.6/1kV Multi-Core PVC Insulated Power Cable with Concentric Copper Conductor and PVC Sheath
NYCY / NAYCY Applications
Power Generation & Industry Конкретно, these cables actively power large-scale plants and industrial facilities.
Distribution Networks Кроме того, utilities actively deploy them for secondary distribution grids and street lighting.
Service Connections Более того, the design securely connects building services and electricity meters.
Underground Installation Furthermore, contractors efficiently install these cables in underground ducts or direct burial systems.
Screening Requirements Следовательно, the concentric conductor actively provides essential functional screening for indoor and outdoor fixed installations.
- Быстрая обработка образцов с помощью индивидуальных решений
- Высококачественные материалы
- Доступные варианты цен
- Глобальная доставка
- Для лучшей защиты данных убедитесь, что все загрузки безопасны
Сохранить в среднем не менее 30%
-
Описание продукта
NYBY/NAYBY Power Cable: Product Description and Specifications
The NYCY Power Cable serves as a versatile low voltage solution featuring PVC insulation, a PVC sheath, and a distinctive concentric copper conductor. Конкретно, while the НИКИ model использует copper main conductors, the NAYCY variant предлагает an aluminium alternative.
Кроме того, the helically applied concentric copper wires and tape act as a combined neutral and protective conductor. This design also provides essential functional screening.
Наконец, you can deploy these cables effectively in industrial power distribution, building supply connections, and underground networks. We ensure they comply with major standards such as МЭК 60502-1.
-
Преимущества
NYBY/NAYBY Power Cable : Benefits and Features
Combined power and concentric PE/neutral conductor in one cable
Copper or aluminium main conductors available (NYCY / NAYCY)
Concentric copper wires and tape provide excellent earthing and screening
PVC insulation and sheath for good mechanical protection
Suitable for underground, duct and building installations
Compliant with IEC 60502-1 / DIN VDE 0276 / HD 603
Specification Of NYBY/NAYBY Power Cable
| Technical Data - Parameter | Technical Data - Value |
|---|---|
| Conductor resistance at 20℃ | according to VDE 0295 and IEC 60228 |
| Core temperature, max: | 70℃ in operation |
| Max.short circuit temperature: | 160℃ , not more than 5 sec |
| Rated voltage - U0 /U (Umax): | 0.6/1(1.2) kV |
| Test voltage: | AC - 4 kV; 50 Hz |
| Диапазон температур | |
| Fixed installation: | -30℃ to +70℃ |
| Flexible Installation: | -5℃ to +50℃ |
| Bending radius, min. | 12xDcable |
| Specific insulation resistance at 70℃: | min,1010Ωx cm |
| max Permessible tensile stress with cable grip: | For Cu conductor = 50 N/mm2; For Al conductor = 30 N/mm2 |
| Cable Structure - Component | Cable Structure - Description |
| Дирижер: | solid or multi-strand Cu or Al wires class 1, 2 or 5 acc. VDE 0295(IEC 60228) |
| Изоляция: | PVC type DIV4 acc. VDE0207 |
| Core identification: | according to VDE 0293 (HD 308) |
| Cores assembly | cores stranded concentrically (cores stranded in concentric layers, for signal) |
| Inner sheath: | rubber filling compaund |
| Concentric copper conductor: | helicoidally copper wires and one copper tape around inner covering |
| Sheat (Sheath): | PVC type DMV5 acc. VDE 0207, black color |
Размеры/параметры
| Number of cores x Nominal Cross Section (No x mm²) | Overall Diameter Approx. (max.mm) | Copper weight Approx. (kg/km) | Total Weight Approx. (kg/km) |
|---|---|---|---|
| 2 x 1.5/1.5 | 14 | 60.0 | 245.0 |
| 2 x 2.5/2.5 | 14 | 85.0 | 285.0 |
| 2 x 4/4 | 16.0 | 125.0 | 360.0 |
| 3x1.5/1.5 | 14.0 | 80.0 | 280.0 |
| 3x2.5/2.5 | 15.0 | 109.0 | 316 |
| 3x4/4 | 17.0 | 155.0 | 423.0 |
| 3x6/6 | 18.0 | 240.0 | 530.0 |
| 3x10/10 | 20.0 | 384.0 | 730.0 |
| 3x16/16 | 22.0 | 610.0 | 970.0 |
| 3x25/16 | 25.0 | 870.0 | 1340.0 |
| 3x35/35 | 27.0 | 1340.0 | 1820.0 |
| 3x50/50 | 31.0 | 1980.0 | 2490.0 |
| 3x70/70 | 35.0 | 2680.0 | 3350.0 |
| 3x95/95 | 40.0 | 3650.0 | 4490.0 |
| 3x120/120 | 43.0 | 4610.0 | 5500.0 |
| 3x150/150 | 48.0 | 5750.0 | 6950.0 |
| 4x1.5/1.5 | 15.0 | 94.0 | 302.0 |
| 4x2.5/2.5 | 16.0 | 133.0 | 360.0 |
| 4x4/4 | 18.0 | 195.0 | 485.0 |
| 4x6/6 | 19.0 | 299.0 | 616.0 |
| 4x10/10 | 21.0 | 480.0 | 850.0 |
| 4x16/16 | 23.0 | 766.0 | 1160.0 |
| 4x25/16 | 28.0 | 1112.0 | 1630.0 |
| 4x35/16 | 30.0 | 1515.0 | 2080.0 |
| 4x50/25 | 34.0 | 2156.0 | 2775.0 |
| 4x70/35 | 38.0 | 3070.0 | 3910.0 |
| 4x95/50 | 43.0 | 4200.0 | 5180.0 |
| 4x120/70 | 48.0 | 5275.0 | 6400.0 |
| 4x150/70 | 53.0 | 6690.0 | 8075.0 |
| 4x185/95 | 58.0 | 8030.0 | 9710.0 |
| 5x1.5/2.5 | 16.0 | 109.0 | 344.0 |
| 5x2.5/2.5 | 17.0 | 158.0 | 412.0 |
| 5x4/4 | 19.0 | 259.0 | 560.0 |
| 5x6/6 | 20.0 | 355.0 | 690.0 |
| 5x10/10 | 23.0 | 575.0 | 965.0 |
| 5x16/16 | 25.0 | 940.0 | 1355.0 |
| 7x1.5/2.5 | 17.0 | 141.0 | 395.0 |
| 8x1.5/2.5 | 17.0 | 155.0 | 440.0 |
| 10x1.5/2.5 | 20.0 | 188.0 | 510.0 |
| 12x1.5/2.5 | 20.0 | 223.0 | 585.0 |
| 14x1.5/2.5 | 21.0 | 253.0 | 640.0 |
| 19x1.5/4 | 23.0 | 325.0 | 780.0 |
| 24x1.5/6 | 26.0 | 407.0 | 950.0 |
| 30x1.5/6 | 27.0 | 494.0 | 1105.0 |
| 7x2.5/2.5 | 18.0 | 209.0 | 490.0 |
| 8x2.5/4 | 19.0 | 233.0 | 550.0 |
| 10x2.5/4 | 21.0 | 291.0 | 670.0 |
| 12x2.5/4 | 22.0 | 339.0 | 730.0 |
| 14x2.5/6 | 23.0 | 397.0 | 825.0 |
| 19x2.5/6 | 25.0 | 516.0 | 1000.0 |
| 24x2.5/10 | 28.0 | 673.0 | 1270.0 |
| 30x2.5/10 | 30.0 | 820.0 | 1495.0 |
-
Production Processes Of Power Cable
Для обеспечения высшего качества, ДЖОКА оперирует полностью оцифрованные и автоматизированные производственные линии для силовые кабели. Конкретно, этот комплексный рабочий процесс покрывает скручивание проводников, экструзия изоляции, металлическое экранирование и окончательная оболочка. Более того, интеллектуальные системы активно мониторить каждый этап для обеспечения стабильной производительности и стабильного качества продукции. Кроме того, фабрика использует передовые испытательные мощности, такие как испытания на частичный разряд, испытания на растяжение и испытания на искру. Следовательно, эти строгие меры гарантия что каждый доставленный кабель строго соответствует международным стандартам.
Упаковка для отправки
Для удовлетворения различных потребностей в транспортировке можно использовать множество способов упаковки.
Есть еще вопросы?
Q: What is the actual function of the concentric copper layer (Ceander)?
А: It serves a dual purpose. First, it acts as the PE or PEN conductor (Protective Earth/Neutral). Second, because it wraps around the cores, it provides effective screening against electromagnetic interference (EMC). This is crucial if you are running power near sensitive data lines or control systems.
Q: NYCY vs. NAYCY: Which one should I specify?
А: It’s strictly a choice of main conductor material. НИКИ is solid Copper (expensive, high conductivity). NAYCY uses Aluminum for the main phases (cheaper, lighter), but keeps the concentric screen in Copper. If budget is tight and the cable run is long, NAYCY is the standard engineering choice.
Q: What is the voltage rating?
А: These are standard low-voltage cables rated for 0.6/1 kV. They are manufactured strictly to DIN VDE 0276-603 и МЭК 60502-1 specifications.
Q: Can I use these underground?
А: Да. They are designed for fixed installation indoors, outdoors, in concrete, and directly underground. The concentric conductor actually adds a layer of safety—if someone accidentally digs into the cable, the tool hits the earth screen first, tripping the breaker before hitting a live phase.
Q: Why choose NYCY over standard NYY cables?
А: Two words: EMC Protection. If you are powering VFDs (Variable Frequency Drives) or equipment in a “noisy” electrical environment (like a data center or automated factory), standard NYY won’t stop the noise. NYCY keeps the interference contained.
Q: What are the temperature constraints?
А: Keep in mind these are PVC insulated cables. Your maximum continuous operating temperature is 70°С. If you have a high-heat application or need to push maximum ampacity, you should look at N2XCY (the XLPE version) instead.
Q: Is installation difficult regarding bending radius?
А: They are stiffer than standard cables due to the concentric layer and the helix tape. You need to respect a bending radius of at least 12x to 15x the cable diameter (single-core vs multi-core) to avoid damaging the copper screen during installation.
Q: How do I get a technical proposal or quote?
А: Just email us your Cable Schedule. We need to know: Main conductor material (Cu or Al), cross-section (e.g., 4×95/50), and total length. We’ll verify the screen cross-section requirements and send you a formal quote ASAP.