H07RN-F
450/750V Heavy Duty Rubber Sheathed Flexible Cable (PCP/Neoprene)
Specifiche Tecniche
Modello: H07RN-F
Tensione nominale: 450/750V
Direttore: Class 5 Flexible Stranded Copper
Materiale di isolamento: High-Quality EPR (Ethylene Propylene Rubber)
Guaina esterna: Heavy-Duty PCP (Polychloroprene / Neoprene)
Operating Temperature: -25°C to +60°C (Mobile) / +85°C (Fixed)
Max. Short Circuit Temp: +200°C (Max. 5 seconds)
Min. Installation Temp: -10°C
Minimum Bending Radius: 6x Overall Diameter (Mobile application)
Conformità agli standard: IEC 60245-4, EN 50525-2-21
- Elaborazione rapida dei campioni con soluzioni personalizzate
- Materiali di alta qualità
- Opzioni di prezzo convenienti
- Consegna globale
- Per una migliore protezione dei dati, assicurati che tutti i caricamenti siano sicuri
Risparmia almeno 30% in media
-
Descrizione del prodotto
H07RN-F : Product Description and Specifications
Il H07RN-F cable is engineered for high-stress power transmission in environments where standard PVC simply fails. By combining flexible stranded copper conductors with EPR (Ethylene Propylene Rubber) insulation, we’ve created a core that maintains electrical integrity even under constant movement. The outer protection consists of a PCP (Polychloroprene) sheath, providing a rugged barrier against oil, chemicals, and mechanical abrasion. Whether deployed for construction site machinery, stage equipment, or mobile power units, JOCA’s H07RN-F strictly adheres to EN 50525-2-21 standards, ensuring safety and performance in the most volatile industrial settings.
-
Vantaggi
H07RN-F : Benefits and Features
Zero Kinking: High-flex stranding stays limp and manageable; coils easily without fighting you.
Impact Ready: The rubber jacket survives crushing loads and dragging over rough concrete.
Oil Defense: Impervious to mineral oils and greases—wipes clean instead of soaking in.
Cold Start: Remains pliable down to -25°C. Won’t stiffen or crack like PVC.
Sun Proof: Native UV resistance allows permanent outdoor use without degradation.
Event Safe: Certified EN 50525-2-21 reliability for public stages and mobile power.
Dimensioni/Parametri
| Dimensioni (N x mmq) | Costruzione del conduttore individuale (n x mm) | Diametro del conduttore max (mm) | Spessore dell'isolamento nominale (mm) | Spessore della guaina nominale (mm) | Diametro esterno min-max (mm) | Resistenza del conduttore a 20 C max (Ohm/km) | Peso Cu (kg/km) | Peso del cavo circa (kg/km) | Imballaggio |
|---|---|---|---|---|---|---|---|---|---|
| 1 x 70 | 356 x 0.50 | 13.0 | 1.6 | 2.6 | 18.6 - 23.3 | 0.272 | 672 | 950 | TAGLIO |
| 1 x 95 | 485 x 0.50 | 15.1 | 1.8 | 2.8 | 20.8 - 26.0 | 0.206 | 912 | 1202 | TAGLIO |
| 2 x 1 | 32 x 0.20 | 1.5 | 0.8 | 1.3 | 7.7 - 10.0 | 19.5 | 19.2 | 105 | TAGLIO |
| 3G1,5 | 30 x 0.25 | 1.8 | 0.8 | 1.6 | 9.2 - 11.9 | 13.3 | 43.2 | 162 | c.100 |
| 4G4 | 56 x 0.30 | 3.2 | 1.0 | 2.0 | 14.0 - 17.9 | 4.95 | 153.6 | 402 | TAGLIO |
| 4G6 | 84 x 0.30 | 3.9 | 1.0 | 2.3 | 15.7 - 20.0 | 3.30 | 230.4 | 561 | TAGLIO |
| 5G4 | 56 x 0.30 | 3.2 | 1.0 | 2.2 | 15.6 - 19.9 | 4.95 | 192 | 470 | TAGLIO |
| 19G1,5 | 30 x 0.25 | 1.8 | 0.8 | 2.5 | 22.5 - 28.0 | 13.3 | 279.0 | 599 | TAGLIO |
| 24G1,5 | 30 x 0.25 | 1.8 | 0.8 | 3.5 | 24.3 - 30.7 | 13.3 | 345.6 | 1000 | TAGLIO |
| 36G1,5 | 30 x 0.25 | 1.8 | 0.8 | 3.8 | 33.0 | 13.3 | 518.4 | - | TAGLIO |
-
Production Processes Of Rubber cable
JOCA produces these cables using Continuous Vulcanization (CV) technology. This automated system synchronizes copper stranding with rubber extrusion, allowing the EPR insulation e PCP outer sheath to cure evenly. This integrated process ensures a consistent, solid bond between layers without structural defects. regarding quality control, we perform routine oil immersion and flexibility tests on production batches to verify compliance with IEC 60245 and EN 50525.
Imballaggio per la spedizione
Per soddisfare le varie esigenze di trasporto, ci sono molti metodi di imballaggio che possono essere utilizzati.
Hai altre domande?
Q: What does the code "H07RN-F" actually break down to?
A: It’s the harmonized ID for the cable’s build:
07: 450/750V Voltage Rating.
R: EPR Rubber Insulation (Not PVC).
N: PCP/Neoprene Outer Sheath.
F: Class 5 Flexible Copper. Essentially, it confirms compliance with EN 50525-2-21 norms.
Q: Where is this cable actually used?
A: Anywhere cables get abused. Standard sites include mobile generators, stage rigs, and drainage pumps. If you need to drag a cable over gravel or run it through puddles, this is the industry standard.
Q: Is it truly oil and water-resistant?
A: Yes. The Neoprene (PCP) jacket is chemically built to block mineral oils and fats—it won’t swell like standard rubber. For water, it handles submersion (typically AD8 rated) for pumps and marine docks.
Q: Can I leave it outdoors permanently?
A: For UV and weather? Yes. The black sheath has native UV resistance and won’t crack in the sun. For sotterraneamente? No. Use a conduit to stop the earth pressure from crushing it.
Q: Why pick H07RN-F over PVC?
A: Cold weather performance. PVC gets stiff and cracks below freezing. H07RN-F rubber stays flexible and manageable down to -25°C. It also takes impact and heat far better than thermoplastic PVC.
Q: What are the real temperature limits?
A:
Moving/Flexing: -25°C to +60°C.
Fixed/Static: Up to +85°C.
Cortocircuito: +200°C (Max 5 seconds).
Q: Is it safety certified?
A: Strictly follows IEC 60245-4 e EN 50525-2-21. This isn’t just a claim; it means the cable passed specific flame retardant (IEC 60332-1-2) and mechanical tear tests.
Q: How do I size the cross-section correctly?
A: Don’t guess. Check two things: Current Load (Amps) e Caduta di tensione. Match your equipment’s draw to our datasheet ampacity, then check the run length. Long runs need thicker copper to stop voltage drop.