Fraude Blocker

JOCA

PV 1500V DC-AL Enkele Kern

DC1500V 2PFG 2642 PV1500DC-AL-K Aluminum alloy solar cable

  • Ground/ Rooftop/ Floating PV Power Plant Application.
  • 25 Years Lifetime & TUV/UL/IEC/CE/Ad8/CPR Certificates
  • Suitable for Harsh Indoor and Outdoor Environments after Electron Irradiation
  • Compatibel met alle belangrijke zonneconnectoren
  • Levering in 7 dagen binnen 200km

 Bespaar gemiddeld minimaal 30%

PV 1500V DC-AL Enkele Kern
  • icon

    Productbeschrijving

    PV 1500V DC-AL Single Core : Product Description and Specifications

The DC1500V 2PFG 2642 Aluminum Alloy Solar Cable offers a flexible, reliable solution for interconnecting PV systems. It strictly complies with global standards, including UL4703, IEC 62930, EN 50618, Ad8, and CPR. Furthermore, it holds certifications from TUV, UL, IEC, and CE.

Therefore, this cable suits large-scale stations, rooftops, and floating projects perfectly. It works effectively on diverse roof types, such as desert sands, lakefronts, or snowy mountain tops. Stable connections guarantee your PV system’s long lifespan. Consequently, this increases output capability and saves on running expenses.

PV 1500V DC-AL Enkele Kern
  • icon

    Voordelen

    PV 1500V DC-AL Single core: Benefits and Features

a.Minimize the weight of cables.

b. Het verzet zich actief tegen externe bedreigingen zoals ozon, zuur en alkali. Bovendien is het bestand tegen barre klimaten, waardoor een levensduur van 25 jaar wordt gegarandeerd.

c. This cable significantly reduces installation costs. You can bury it directly in the ground. Moreover, it supports series or parallel connections.

d.Carrying capacity meets the requirements.

e.Aluminum conductors meet Copper-aluminum connection safety mechanical properties standards.

f.Copper-Aluminium joint connectors, plus cable jointings

PV 1500V DC-AL Single Core Specifications

Kabelbouw
Conductor2 PFG 2642 vijfde flexibele geleider van aluminiumlegering
IsolatieLSZH verknoopt Polyolefine (120°C)
BuitenschedeLSZH verknoopt Polyolefine (120°C)
SchedekleurZwart rood
Nominale VoltageDC1500V
Test VoltageAC6.5kV/5min of DC15kV/5min zonder afbraak Leider maximum het werk temperatuur wanneer lucht het leggen:120°C/2000h
Leider lange termijn het werk temperatuur90°C
Omgevingstemperatuur-40°C~+90°C
Maximale kortsluitingstemperatuur≤250°C/5S
Verwachte levensduur25 jaar
Buigradius6×D
BrandprestatiesIEC 60332-1
ZoutnevelemissieIEC 61034;EN 50268-2
Lage brandbelastingDIN51900
ProductcertificeringTUV 2 PFG 2642/01.22

Afmetingen/parameters

Specificatie(mm²)Conductor Construction(n x mm)Isolatie Normale Dikte (mm)Schede Normale Dikte (mm)Outer Diameter(mm)Max DC Weerstand van Leider bij 20 °C (Ω/Km)Min Isolatieweerstand bij 90 °C (mΩ/Km)
1×4.056x0.30.70.82.598.10.709
1×6.084x0.30.70.83.175.050.61
1×1080x0.40.80.84.123.080.489
1×16126x0.40.90.95.181.910.395
1x25199x0.4117.361.20.393
1x35278x0.41.11.18.70.8680.335
1x50398x0.41.21.210.40.6410.314

Certifications Of PV1500DC-AL-K Solar Cabl

Certificeringen van CPR CCA H1Z2Z2-K zonnekabel
  • icon

    Productieprocessen van fotovoltaïsche draad

The smart and digital setup of JOCA cable factory is one that streamlines production processes as well as inspection. This improves the product’s reliability through manual assembly errors reduction by integrating them with intelligent and digital technologies. The factory employs advanced tools like digital image detection and laser technology in its inspection ceremony to ensure high quality products with peak performance.

Productieprocessen van fotovoltaïsche draad

Verpakking voor verzending

Different packaging techniques have been adapted to meet specific transportation needs

Packing PicturesVerpakkingsmethode Aantal/pallet(stuks)Meter/pallet (M)GW/pallet(KGS)Palletgrootte (m)Pallet/20GPMeter/20GP
packing100M/ROL4mm²-176 stuks4mm²-17600m4mm²-1144kg1,12x1,12x1,12m204mm²-352000m
6mm²-160 stuks6mm²-16000m6mm²-1360kg6mm²-320000m
packing200M/ROL4mm²-90 st4mm²-18000m4mm²-1170kg1,12x1,12x1,12m204mm²-360000m
6mm²-81 stuks6mm²-16200m6mm²-1377kg6mm²-324000m
packing100m/plastic trommel4mm²-125 stuks4mm²-12500m4mm²-850kgs1,12x1,12x1,12m204mm²-250000m
6mm²-100 stuks6mm²-10000m6mm²-900kgs6mm²-200000m
packing500m/houten trommel4mm²-27 stuks4mm²-13500m4mm²-1197kg1.12x1.12x1.12204mm²-270000m
6mm²-27 stuks6mm²-13500m6mm²-930kgs6mm²-270000m
packing1000M/houten trommel4mm²-12 stuks4mm²-12000m4mm²-830kgs1.12x1.12x1.12204mm²-240000m
6mm²-12 stuks6mm²-12000m6mm²-1070kgs6mm²-240000m
Verpakking voor verzending

Heb je nog meer vragen?

Vind antwoorden op veelgestelde vragen over ons bedrijf en onze diensten voor een naadloos begin.

Q: What is a PV 1500V DC-AL single core cable?

A: A PV 1500V DC-AL Single Core Cable, it is a solar cable type designed for power generation in photovoltaic systems. It can achieve high voltage levels of 1500 VDC which are applicable to the interconnection of solar panels and inverters in large-scale roofs or ground farms. These cables typically have one conductor, made of copper or aluminium and have been optimized to transmit electricity well with minimal loss.

Q: What are the technical properties of 1500V DC solar cables?

A: The primary features of every 1500V DC Solar Cable, including PV 1500V DC-AL single core, involve high temperature and UV resistance so that they can survive extreme environments, as visible in outdoor solar installations. Also, these cords are meant to be flame-retardant, halogen-free, ozone-resistant, and radiation-resistant, which helps develop safer and more dependable power generation systems. For instance, while maintaining some flexibility and durability necessary during installation, insulation materials used in this case were chosen on purpose to protect against all such factors.

Q: How does the size and material of a conductor affect the performance of a solar cable?

A: The size (normally in mm2 e.g., 6mm2 for some solar cables) and material (usually copper or aluminum) of conductors significantly determine how well a given type of solar cable performs. Larger sizes plus materials featuring lower resistivity, like copper, can transfer more current efficiently because they lose less heat energy than smaller sizes or those having higher-resistance conductors, making them more appropriate for photovoltaic systems transmitting high powers over long distances.

Q: Can PV 1500V DC-AL single core cables be used in all types of solar installations?

A: Truly versatile, PV 1500V DC-AL single core cables find applications even residential rooftops, commercial rooftops and large-scale ground farms. Being robust and having a high voltage rating, they can be installed underground or over the air to link string boxes to inverters. Nonetheless, when selecting the cable type and size, one should take into account particular installation conditions and statutory requirements.

Q: What certifications should I look for in a high-quality solar cable?

A: Highly-rated solar cables such as PV 1500V DC-AL single core must have certified indications that guarantee strict international safety, performance and durability standards are met. Some notable certificates include those covered by TUV, which are European specifications, and other types of relevant certification covering international requirements for photovoltaic systems or regulations of certain countries. These are verifications of the capacity of a cable to withstand all possible conditions in photovoltaic installations.

Q: How important is the solar cable’s resistance to UV and ozone in solar installations?

A: It is important for solar cables to resist UV radiation and ozone especially if they are to be used in solar installations that will be exposed continuously to direct sunlight as well as different outdoor elements. The reason why there are UV-resistant cables is so that they can stand being exposed to sun rays without breaking down, whereas ozone-resistant ones prevent them from degrading due to huge concentrations of ozone. All these characteristics are very necessary because they guarantee reliable operation within long-term frames of reference, i.e., they help avoid an untimely failure of conductors thus maintaining system integrity levels at maximums throughout the lifetime operations of any given power station.

Q: What role does the insulation thickness play in the performance of a PV cable?

A: One of the most important factors for consideration when designing and installing a solar power plant is the insulation thickness on all PV cables. This ensures safety by preventing electrical shock and short circuits, and it also guards them from mechanical and environmental stress. Moreover, it contributes to the overall resistance of the cables against UV rays and ozone as well as high temperatures. The specific requirements for insulation thickness depend on the cable’s voltage rating, application, and environmental conditions.

Q: How to choose the right supplier for PV 1500V DC-AL single core cables?

A: There are several things to consider before selecting among potential manufacturers of PV1500V DC-AL single core cables, including product accreditation/ certification, support provided during the technical installation process, quality assurance processes followed by a manufacturing company or organization that produces such products, and finally, historical background of that company in this industry sector. In addition, search for suppliers who can offer TUV-certified/ compliant Cables. Additionally, go with one that provides full sales back-up, including technical advice tailored to your particular installation circumstances as well as your safety & reliability criteria.

Scroll naar boven
Neem contact op met het bedrijf JOCA

Vul dan het onderstaande formulier in om contact met ons op te nemen Wij streven ernaar om binnen 12 uur contact met u op te nemen Ik wens u het allerbeste!

Contact Formulier Demo

JOCA