- Construction: Concentrically stranded Aluminum (1350-H19, 6201-181) or ACSR.
- Isolatie: Weather-resistant PE, HDPE, or XLPE.
- Toepasselijke normen:
- ASTM: B-230, B-231, B-1248, C-8.35
- ICEA: S-61-402
- NEMA: WC 5-1973
- Snelle monsterverwerking met oplossingen op maat
- Hoogwaardige materialen
- Betaalbare Prijs Opties
- Global Delivery
- Zorg er voor een betere gegevensbescherming voor dat alle uploads veilig zijn
Bespaar gemiddeld minimaal 30%
-
Productbeschrijving
Covered Aluminum Line Wire Weatherproof : Product Description and Specifications
Engineered specifically for overhead secondary distribution, this series utilizes 1350-H19, 6201-T81, or ACSR conductors encased in a weather-resistant polymer jacket (PE, HDPE, or XLPE). Critical Safety Note: The covering provides mechanical shielding against atmospheric corrosion and abrasion only; it is strictly not electrically insulated. Field crews must treat this product as a bare conductor at all times to ensure operational safety, as the polymer layer offers zero dielectric containment voltage.
-
Voordelen
Covered Aluminum Line Wire Weatherproof : Benefits and Features
Transient Fault Barrier: Not insulation. Acts as physical shield against momentary phase-to-phase contact (clashing) or vegetation touches. Prevents immediate arc-faults.
Atmospheric Sealing: Polymer jacket blocks UV radiation and saline mist. Result: Zero galvanic corrosion on the aluminum core.
Span Geometry: Retains high strength-to-weight ratio (ACSR/Alloy base). Engineering benefit: Supports extended pole spacing unlike fully insulated aerial cables.
Specification Of Covered Aluminum Line Wire Weatherproof
| Item # | Size AWG or MCM | Strand | Outside Diameter | Rated Breaking Strength | Weight Per MFT XLP | Weight Per MFT Poly | Ampacity XLP |
|---|---|---|---|---|---|---|---|
| Apple | 6 | Solid | .222 Inches | 445 Lbs | 33.0 Lbs | 32.0 Lbs | 105 Amps |
| Pear | 4 | Solid | .264 Inches | 675 Lbs | 48.5 Lbs | 47.3 Lbs | 135 Amps |
| Apricot | 4 | 7/w | .285 Inches | 790 Lbs | 51.5 Lbs | 50.8 Lbs | 140 Amps |
| Peach | 2 | 7/w | .373 Inches | 1220 Lbs | 87.1 Lbs | 84.0 Lbs | 180 Amps |
| Quince | 1/0 | 7/w | .477 Inches | 1790 Lbs | 140.7 Lbs | 135.6 Lbs | 240 Amps |
| Orange | 2/0 | 7/w | .522 Inches | 2260 Lbs | 171.9 Lbs | 166.2 Lbs | 280 Amps |
| Fig | 3/0 | 7/w | .570 Inches | 2740 Lbs | 210.5 Lbs | 204.0 Lbs | 320 Amps |
| Olive | 4/0 | 7/w | .626 Inches | 3450 Lbs | 258.7 Lbs | 251.4 Lbs | 370 Amps |
| Pomegranate | 4/0 | 19/w | .632 Inches | 3620 Lbs | 254.8 Lbs | 247.9 Lbs | 370 Amps |
| Mulberry | 266.8 | 19/w | .692 Inches | 4470 Lbs | 313.5 Lbs | 305.8 Lbs | 430 Amps |
| Anona | 336.4 | 19/w | .766 Inches | 5535 Lbs | 387.6 Lbs | 378.8 Lbs | 495 Amps |
| Molles | 397.5 | 19/w | .852 Inches | 6400 Lbs | 469.2 Lbs | 457.4 Lbs | 545 Amps |
| Huckleberry | 477.0 | 37/w | .921 Inches | 7820 Lbs | 550.0 Lbs | 537.5 Lbs | 610 Amps |
| Paw Paw | 556.5 | 37/w | .982 Inches | 8950 Lbs | 633.0 Lbs | 619.4 Lbs | 670 Amps |
| Breadfruit | 636.0 | 61/w | 1.080 Inches | 10510 Lbs | 742.6 Lbs | 724.7 Lbs | 720 Amps |
| Persimmon | 795.0 | 61/w | 1.187 Inches | 12900 Lbs | 910.0 Lbs | 890.0 Lbs | 825 Amps |
| Item # | Size AWG or MCM | Strand | Outside Diameter | Rated Breaking Strength | Weight Per MFT XLP | Weight Per MFT Poly | Ampacity XLP |
|---|---|---|---|---|---|---|---|
| Walnut | 6 | 6/1 | .258 Inches | 1131 Lbs | 49 Lbs | 47 Lbs | 105 Amps |
| Butternut | 4 | 6/1 | .303 Inches | 1170 Lbs | 71.8 Lbs | 70.0 Lbs | 135 Amps |
| Hickory | 4 | 7/1 | .309 Inches | 2240 Lbs | 81.6 Lbs | 79.8 Lbs | 135 Amps |
| Pignut | 2 | 6/1 | .397 Inches | 2710 Lbs | 118.1 Lbs | 114.8 Lbs | 180 Amps |
| Beech | 2 | 7/1 | .405 Inches | 3460 Lbs | 134.1 Lbs | 130.7 Lbs | 180 Amps |
| Chestnut | 1 | 6/1 | .434 Inches | 3370 Lbs | 145.5 Lbs | 141.8 Lbs | 210 Amps |
| Almond | 1/0 | 6/1 | .506 Inches | 4160 Lbs | 190.4 Lbs | 184.9 Lbs | 235 Amps |
| Pecan | 2/0 | 6/1 | .554 Inches | 5040 Lbs | 234.2 Lbs | 227.9 Lbs | 270 Amps |
| Filbert | 3/0 | 6/1 | .607 Inches | 6290 Lbs | 288.5 Lbs | 281.4 Lbs | 305 Amps |
| Buckeye | 4/0 | 6/1 | .666 Inches | 7930 Lbs | 356.5 Lbs | 348.5 Lbs | 345 Amps |
| Hackberry | 266.8 | 18/1 | .711 Inches | 6540 Lbs | 354.8 Lbs | 346.8 Lbs | 435 Amps |
| Item # | Size AWG or MCM | Strand | Outside Diameter | Rated Breaking Strength | Weight Per MFT XLP | Weight Per MFT Poly | Ampacity XLP |
|---|---|---|---|---|---|---|---|
| Hornbeam | 4 | 7/w | .310 Inches | 1480 Lbs | 62.1 Lbs | 60.1 Lbs | 145 Amps |
| Linden | 2 | 7/w | .406 Inches | 2520 Lbs | 96.1 Lbs | 93.3 Lbs | 190 Amps |
| Oilnut | 1/0 | 7/w | .518 Inches | 4010 Lbs | 166.1 Lbs | 160.0 Lbs | 250 Amps |
| Waterash | 2/0 | 7/w | .567 Inches | 4850 Lbs | 203.3 Lbs | 196.4 Lbs | 290 Amps |
| Shellbark | 3/0 | 7/w | .622 Inches | 6110 Lbs | 249.4 Lbs | 241.4 Lbs | 335 Amps |
| Planetree | 4/0 | 7/w | .683 Inches | 7700 Lbs | 307.3 Lbs | 298.1 Lbs | 385 Amps |
-
Productieprocessen van luchtgebundelde kabels
De luchtkabel productie-infrastructuur werkt een gesloten-lus digitale automatisering systeem, integratie van geleider stranding, isolatie extrusie, en uiteindelijke omhulling in een continue workflow Processtabiliteit is afhankelijk van ingebedde sensorarrays volgen extrusie parameters in real-time, het elimineren van handmatige varianties Kwaliteit validatie wordt afgedwongen door middel van specifieke in-line hardware, waaronder dual-axis laserdiameter meters en hoogspanning vonktesters, terwijl het fysieke laboratorium voert destructieve trek - en rekanalyse om naleving van internationale normen te controleren vóór verzending.
Verpakking voor verzending
Om aan verschillende transportbehoeften te voldoen, zijn er veel verpakkingsmethoden die kunnen worden gebruikt.
Heb je nog meer vragen?
Q: Is de draad elektrisch geïsoleerd?
A: Negatief. De polymeerbekleding is een mechanisch schild alleen. Het houdt diëlektrische classificatie nul.
Q: Primaire Toepassing?
A: Secundaire overheadverdeling (<600V). Opmerking: Moet op isolatoren worden geïnstalleerd, identiek aan bare wire-protocollen.
Vraag: Vegetatie/boomcontact?
A: Verboden. De bekleding is bestand tegen slijtage, maar zal boogfouten niet voorkomen bij contact Standaard goedkeuringscodes van toepassing.
Vraag: Materiaalselectie: PE versus XLPE?
A:
HDPE: Beste voor fysieke taaiheid/rupsweerstand.
XLPE: Beste voor hogere thermische bedrijfsgrenzen.
Q: Ampaciteit Berekening?
A: Do not use bare wire tables. Refer to NEC (or local code) specifically for “Covered Conductors” to account for thermal retention.
Q: Installation Hardware?
A: Uses standard Bare Wire fittings (ties, clamps, dead-ends). No specialized insulated connectors required.
Q: Conductor Options?
A: Beschikbaar in AAC (1350-H19), AAAC (6201 Alloy), or ACSR (Steel Reinforced) depending on span strength requirements.
Q:Standard Color & UV?
A: Black. (Contains Carbon Black). This ensures maximum UV stability for long-term outdoor exposure.