Bloqueador de fraude

JOCA

Cable de línea de aluminio cubierto resistente a la intemperie

Conductor cubierto resistente a la intemperie para líneas aéreas de distribución

  • Construcție: Concentrically stranded Aluminum (1350-H19, 6201-181) or ACSR.
  • Aislamiento: Weather-resistant PE, HDPE, or XLPE.
  • Applicable Standards:
    • ASTM: B-230, B-231, B-1248, C-8.35
    • ICEA: S-61-402
    • NEMA: WC 5-1973

 Ahorre al menos 30% en promedio

CABLE AL LINE CUBIERTO RESISTENTE A LA INTEMPERIE_1
  • icono

    Descripción del producto

    Covered Aluminum Line Wire Weatherproof : Product Description and Specifications

Engineered specifically for overhead secondary distribution, this series utilizes 1350-H19, 6201-T81, or ACSR conductors encased in a weather-resistant polymer jacket (PE, HDPE, or XLPE). Nota crítica de seguridad: The covering provides mechanical shielding against atmospheric corrosion and abrasion only; it is strictly not electrically insulated. Field crews must treat this product as a bare conductor at all times to ensure operational safety, as the polymer layer offers zero dielectric containment voltage.

COVERED AL LINE WIRE WEATHERPROOF
  • icono

    Ventajas

    Covered Aluminum Line Wire Weatherproof : Benefits and Features

  • Transient Fault Barrier: Not insulation. Acts as physical shield against momentary phase-to-phase contact (clashing) or vegetation touches. Prevents immediate arc-faults.

  • Atmospheric Sealing: Polymer jacket blocks UV radiation and saline mist. Resultado: Zero galvanic corrosion on the aluminum core.

  • Span Geometry: Retains high strength-to-weight ratio (ACSR/Alloy base). Engineering benefit: Supports extended pole spacing unlike fully insulated aerial cables.

Specification Of Covered Aluminum Line Wire Weatherproof

AAC Aluminum Conductor Specifications (Covered Line Wire)
Item #Size AWG or MCMStrandOutside DiameterRated Breaking StrengthWeight Per MFT XLPWeight Per MFT PolyAmpacity XLP
Apple6Solid.222 Inches445 Lbs33.0 Lbs32.0 Lbs105 Amps
Pear4Solid.264 Inches675 Lbs48.5 Lbs47.3 Lbs135 Amps
Apricot47/w.285 Inches790 Lbs51.5 Lbs50.8 Lbs140 Amps
Peach27/w.373 Inches1220 Lbs87.1 Lbs84.0 Lbs180 Amps
Quince1/07/w.477 Inches1790 Lbs140.7 Lbs135.6 Lbs240 Amps
Naranja2/07/w.522 Inches2260 Lbs171.9 Lbs166.2 Lbs280 Amps
Fig3/07/w.570 Inches2740 Lbs210.5 Lbs204.0 Lbs320 Amps
Olive4/07/w.626 Inches3450 Lbs258.7 Lbs251.4 Lbs370 Amps
Pomegranate4/019/w.632 Inches3620 Lbs254.8 Lbs247.9 Lbs370 Amps
Mulberry266.819/w.692 Inches4470 Lbs313.5 Lbs305.8 Lbs430 Amps
Anona336.419/w.766 Inches5535 Lbs387.6 Lbs378.8 Lbs495 Amps
Molles397.519/w.852 Inches6400 Lbs469.2 Lbs457.4 Lbs545 Amps
Huckleberry477.037/w.921 Inches7820 Lbs550.0 Lbs537.5 Lbs610 Amps
Paw Paw556.537/w.982 Inches8950 Lbs633.0 Lbs619.4 Lbs670 Amps
Breadfruit636.061/w1.080 Inches10510 Lbs742.6 Lbs724.7 Lbs720 Amps
Persimmon795.061/w1.187 Inches12900 Lbs910.0 Lbs890.0 Lbs825 Amps
ACSR Core Variant: Weatherproof Line Wire
Item #Size AWG or MCMStrandOutside DiameterRated Breaking StrengthWeight Per MFT XLPWeight Per MFT PolyAmpacity XLP
Walnut66/1.258 Inches1131 Lbs49 Lbs47 Lbs105 Amps
Butternut46/1.303 Inches1170 Lbs71.8 Lbs70.0 Lbs135 Amps
Hickory47/1.309 Inches2240 Lbs81.6 Lbs79.8 Lbs135 Amps
Pignut26/1.397 Inches2710 Lbs118.1 Lbs114.8 Lbs180 Amps
Beech27/1.405 Inches3460 Lbs134.1 Lbs130.7 Lbs180 Amps
Chestnut16/1.434 Inches3370 Lbs145.5 Lbs141.8 Lbs210 Amps
Almond1/06/1.506 Inches4160 Lbs190.4 Lbs184.9 Lbs235 Amps
Pecan2/06/1.554 Inches5040 Lbs234.2 Lbs227.9 Lbs270 Amps
Filbert3/06/1.607 Inches6290 Lbs288.5 Lbs281.4 Lbs305 Amps
Buckeye4/06/1.666 Inches7930 Lbs356.5 Lbs348.5 Lbs345 Amps
Hackberry266.818/1.711 Inches6540 Lbs354.8 Lbs346.8 Lbs435 Amps
Alloy 6201-T81 Standard: Aluminum Conductor Data
Item #Size AWG or MCMStrandOutside DiameterRated Breaking StrengthWeight Per MFT XLPWeight Per MFT PolyAmpacity XLP
Hornbeam47/w.310 Inches1480 Lbs62.1 Lbs60.1 Lbs145 Amps
Linden27/w.406 Inches2520 Lbs96.1 Lbs93.3 Lbs190 Amps
Oilnut1/07/w.518 Inches4010 Lbs166.1 Lbs160.0 Lbs250 Amps
Waterash2/07/w.567 Inches4850 Lbs203.3 Lbs196.4 Lbs290 Amps
Shellbark3/07/w.622 Inches6110 Lbs249.4 Lbs241.4 Lbs335 amperios
Planetree4/07/w.683 Inches7700 Lbs307.3 Lbs298.1 Lbs385 Amps
  • icono

    Procesos de producción de cables aéreos agrupados

La infraestructura de fabricación de cables aéreos opera un sistema de automatización digital de circuito cerrado, que integra el trenzado del conductor, la extrusión del aislamiento y el revestimiento final en un flujo de trabajo continuo. La estabilidad del proceso se basa en conjuntos de sensores integrados que rastrean los parámetros de extrusión en tiempo real, eliminando las variaciones manuales. La validación de la calidad se aplica a través de hardware en línea específico, incluidos medidores de diámetro láser de doble eje y probadores de chispas de alto voltaje, mientras que el laboratorio físico realiza análisis destructivos de tracción y alargamiento para verificar el cumplimiento de los estándares internacionales antes del envío.

Procesos de Producción de Alambre Fotovoltaico

Embalaje para envío

Para satisfacer diversas necesidades de transporte, existen muchos métodos de embalaje que se pueden utilizar.

Embalaje para envío

¿Tienes más preguntas?

A continuación, recopilamos las preguntas más comunes sobre especificaciones, estándares de seguridad y aplicaciones. Si no ve lo que está buscando o tiene un requisito personalizado específico, simplemente comuníquese directamente con nuestro equipo de ingeniería.

Q: Is the wire electrically insulated?

 A: Negative. The polymer covering is a mechanical shield only. It holds zero dielectric rating.

P: ¿Aplicación primaria?

A: Secondary overhead distribution (<600V). Nota: Must be installed on insulators, identical to bare wire protocols.

 

Q: Vegetation/Tree Contact?

A: Prohibido. The covering resists abrasion but will not prevent arc-faults upon contact. Standard clearance codes apply.

 

Q: Material Selection: PE vs. XLPE?

A:

  • HDPE: Best for physical toughness/track resistance.

     
  • XLPE: Best for higher thermal operating limits.

Q: Ampacity Calculation?

A: Do not use bare wire tables. Refer to NEC (or local code) specifically for “Covered Conductors” to account for thermal retention.

 

Q: Installation Hardware?

A: Uses standard Alambre desnudo fittings (ties, clamps, dead-ends). No specialized insulated connectors required.

Q: Conductor Options?

A: Disponible en AAC (1350-H19), AAAC (6201 Alloy), or ACSR (Steel Reinforced) depending on span strength requirements.

Q:Standard Color & UV?

A: Black. (Contains Carbon Black). This ensures maximum UV stability for long-term outdoor exposure.