AAC 1350 Conductor
High-Conductivity Aluminum Conductor for Overhead Transmission Lines
CONDUCTORS : The AAC 1350 Conductor features a concentric lay stranded design consisting of Aluminum Alloy 1350-H19 wires. Specifically, this AAC 1350 Conductor is available in both single-layer and multi-layer constructions to suit various overhead line requirements.
- STANDARDS :
- American Standard & Canadian national standards ASTM B-230, ASTM B-231, CSA C49
- British Standards BS EN 50182 / BS 215
- German Standards DIN 48201-5
- International Electrotechnical Commission International Standards & China national standards IEC 61089, GB/T 1179
- Australian/New Zealand Standards AS/NZS 1531-91
- Russian National Standard GOST 839-80
- Procesare rapidă a probelor cu soluții personalizate
- Materiale de înaltă calitate
- Opțiuni de preț accesibile
- Livrare globală
- Pentru o mai bună protecție a datelor, asigurați-vă că toate încărcările sunt sigure
Economisiți cel puțin 30% în medie
-
Descrierea produsului
AAC 1350 Conductor : Product Description and Specifications
The AAC 1350 is a high-conductivity solution engineered for overhead power lines. At JOCA, we build these conductors using concentric lay stranded 1350-H19 aluminum alloy. Depending on your span and tension requirements, the cable comes in either single-layer or multi-layer configurations. We don’t just aim for quality; the entire production follows international distribution standards to ensure the wire handles grid loads without sagging or failing. It’s a clean, efficient choice for modern power networks where weight and conductivity are the top priorities.
-
Avantaje
AAC 1350 Conductor : Benefits and Features
99.5% Pure Aluminum: High-conductivity 1350-H19 wires for low-loss transmission.
Oxide Protection: Naturally anti-corrosive material for long-term outdoor service.
Low Pole-Load: All-aluminum build reduces mechanical strain on infrastructure.
Conformitate standard: Verified against ASTM B-230 and B-231 benchmarks.
Economic Design: High electrical performance at a lower material cost.
Specification Of AAC 1350 Conductor
| Categorie | Region/Organization | Standard Code / Description |
|---|---|---|
| Descriere | General | Concentric lay stranded conductor consisting of Aluminum Alloy 1350-H19 wires. AAC is available in both single layer and multi-layer constructions. |
| Standard | American Standard & Canadian national standards | ASTM B-230, ASTM B-231, CSA C49 |
| Standard | British Standards | BS EN 50182 / BS 215 |
| Standard | German Standards | DIN 48201-5 |
| Standard | International Electrotechnical Commission International Standards & China national standards | IEC 61089, GB/T 1179 |
| Standard | Australian/New Zealand Standards | AS/NZS 1531-91 |
| Standard | Russian National Standard | GOST 839-80 |
Dimensiuni/Parametri
| Code | Nominal Area (AWG&MCM) | Nominal Area (mm^2) | Stranding (No.x mm) | Overall Diameter (mm) | Weight (kg/km) | Rated Strength (KN) | Electrical Resistance (Ω/Km) | Current Rating (A) |
|---|---|---|---|---|---|---|---|---|
| Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.53 | 2.1477 | 75 |
| Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.91 | 1.3606 | 99 |
| Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 5.99 | 0.8567 | 132 |
| Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 | 153 |
| Poppy | 1/0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.84 | 0.5369 | 176 |
| Aster | 2/0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 | 203 |
| Phlox | 3/0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 | 234 |
| Oxlip | 4/0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 | 270 |
| Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 | 299 |
| Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 | 299 |
| Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 | 312 |
| Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 | 311 |
| Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 | 335 |
| Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 | 359 |
| Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 | 369 |
| Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 | 397 |
| Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 | 429 |
| Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 | 444 |
| Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 | 444 |
| Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 | 458 |
| Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 | 458 |
| Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 | 489 |
| Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 | 490 |
| Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 | 511 |
| Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 | 530 |
| Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 | 538 |
| Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 | 561 |
| Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 | 561 |
| Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 | 569 |
| Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 | 568 |
| Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 | 587 |
| Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 | 586 |
| Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 | 607 |
| Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 | 605 |
| Snapdragon | 900 | 456 | 61/3.09 | 27.81 | 1256 | 70.8 | 0.0628 | 654 |
| Cockscomb | 900 | 456 | 37/3.96 | 27.72 | 1256 | 68.4 | 0.0631 | 652 |
| Goldenrod | 954 | 483.4 | 61/3.18 | 28.62 | 1331 | 75 | 0.0593 | 677 |
| Magnolia | 954 | 483.4 | 37/4.08 | 28.56 | 1331 | 72.6 | 0.0594 | 676 |
| Camellia | 1000 | 506.7 | 61/3.25 | 29.25 | 1394 | 78.3 | 0.0568 | 695 |
| Hawkweed | 1000 | 506.7 | 37/4.18 | 29.26 | 1395 | 76.2 | 0.0566 | 696 |
| Larkspur | 1033.5 | 523.7 | 61/3.31 | 29.79 | 1442 | 81.3 | 0.0547 | 710 |
| Bluebell | 1033.5 | 523.7 | 37/4.25 | 29.75 | 1441 | 78.8 | 0.0547 | 710 |
| Marigold | 1113 | 564 | 61/3.43 | 30.87 | 1553 | 87.3 | 0.051 | 740 |
| Hawthorn | 1192.5 | 604.2 | 61/3.55 | 31.95 | 1662 | 93.5 | 0.0476 | 771 |
| Narsissus | 1272 | 644.5 | 61/3.67 | 33.03 | 1774 | 98.1 | 0.0445 | 802 |
| Columbine | 1351 | 694.8 | 61/3.78 | 34.02 | 1884 | 104 | 0.042 | 829 |
| Carnation | 1431 | 725.1 | 61/3.89 | 35.01 | 1997 | 108 | 0.0396 | 858 |
| Gladiolus | 1510.5 | 765.4 | 61/4.00 | 36 | 2108 | 114 | 0.0375 | 885 |
| Coreopsis | 1590 | 805.7 | 61/4.10 | 36.9 | 2216 | 120 | 0.0357 | 911 |
| Jessamine | 1750 | 886.7 | 61/4.30 | 38.7 | 2442 | 132 | 0.0324 | 962 |
| Cowslip | 2000 | 1013 | 91/3.77 | 41.47 | 2787 | 153 | 0.0286 | 1032 |
| Sagebrush | 2250 | 1140 | 91/3.99 | 43.89 | 3166 | 167 | 0.0255 | 1099 |
| Lupine | 2500 | 1267 | 91/4.21 | 46.31 | 3519 | 186 | 0.0229 | 1163 |
| Bitterrot | 2750 | 1393 | 91/4.42 | 48.62 | 3872 | 205 | 0.0208 | 1223 |
| Trillium | 3000 | 1520 | 127/3.90 | 50.7 | 4226 | 223 | 0.0193 | 1271 |
| Bluebonnet | 3500 | 1773 | 127/4.22 | 54.86 | 4977 | 261 | 0.0165 | 1373 |
| Code | Nominal Area (Nominal mm^2) | Nominal Area (Teorical mm^2) | Stranding (No.x mm) | Overall Diameter (mm) | Weight (kg/km) | Rated Strength (KN) | Electrical Resistance (Ω/Km) | Current Rating (A) |
|---|---|---|---|---|---|---|---|---|
| Midge | 22 | 23.33 | 7/2.06 | 6.18 | 64 | 3.99 | 1.227 | 106 |
| Gnat | 25 | 26.8 | 7/2.21 | 6.6 | 73.8 | 4.83 | 1.0643 | 122 |
| Mosquito | 35 | 37.0 | 7/2.59 | 7.8 | 102.1 | 6.27 | 0.7749 | 141 |
| Ladybird | 40 | 42.8 | 7/2.79 | 8.4 | 117.9 | 7.28 | 0.6678 | 157 |
| Ant | 50 | 52.83 | 7/3.10 | 9.3 | 145 | 8.28 | 0.5419 | 175 |
| Fly | 60 | 63.55 | 7/3.40 | 10.2 | 174 | 9.9 | 0.4505 | 196 |
| Bluebottle | 70 | 73.7 | 7/3.66 | 11.0 | 202 | 11.34 | 0.3881 | 215 |
| Earwing | 75 | 78.5 | 7/3.78 | 11.4 | 215 | 11.94 | 0.3644 | 232 |
| Grasshopper | 80 | 84.1 | 7/3.91 | 11.7 | 230 | 12.78 | 0.3406 | 249 |
| Clegg | 90 | 95.6 | 7/4.17 | 12.5 | 262 | 14.53 | 0.2944 | 253 |
| Wasp | 100 | 106 | 7/4.39 | 13.17 | 290 | 16.00 | 0.2702 | 268 |
| Beetle | 100 | 106.0 | 19/2.67 | 13.4 | 293 | 17.42 | 0.2704 | 260 |
| Bee | 125 | 132.0 | 7/4.90 | 14.7 | 361 | 19.44 | 0.2169 | 325 |
| Cricket | 150 | 157.9 | 7/5.36 | 16.1 | 432 | 23.85 | 0.1818 | 345 |
| Hornet | 150 | 157.6 | 19/3.25 | 16.25 | 434 | 25.7 | 0.1825 | 342 |
| Caterpillar | 175 | 186 | 19/3.53 | 17.7 | 512 | 28.63 | 0.1547 | 399 |
| Chater | 200 | 213.2 | 19/3.78 | 18.9 | 587 | 35.4 | 0.1349 | 412 |
| Spider | 225 | 236.9 | 19/3.99 | 20.0 | 652 | 36.01 | 0.1211 | 462 |
| Cockroach | 250 | 265.7 | 19/4.22 | 21.1 | 731 | 40.4 | 0.1083 | 471 |
| Butterfly | 300 | 322.7 | 19/4.65 | 23.25 | 888 | 48.75 | 0.08916 | 530 |
| Moth | 350 | 373.3 | 19/5.00 | 25.0 | 1027 | 56.37 | 0.07711 | 562 |
| Drone | 350 | 373.3 | 37/3.58 | 25.1 | 1029 | 57.45 | 0.07741 | 560 |
| Locust | 400 | 428.5 | 19/5.36 | 26.8 | 1179 | 64.73 | 0.06710 | 580 |
| Centipede | 400 | 415.2 | 37/3.78 | 26.46 | 1145 | 63.1 | 0.06944 | 616 |
| Maybug | 475 | 486.1 | 37/4.09 | 28.6 | 1342 | 74.01 | 0.05900 | 740 |
| Scorpion | 500 | 529.8 | 37/4.27 | 29.9 | 1460 | 79.98 | 0.05400 | 887 |
| Cicada | 600 | 628.3 | 37/4.65 | 32.6 | 1733 | 94.95 | 0.04500 | 1056 |
| Tarantula | 750 | 794.6 | 37/5.23 | 36.6 | 2191 | 120.1 | 0.03627 | 1320 |
| Nominal Area (Nominal mm^2) | Nominal Area (Teorical mm^2) | Stranding (No.x mm) | Overall Diameter (mm) | Weight (kg/km) | Rated Strength (KN) | Electrical Resistance (Ω/Km) | Current Rating (A) |
|---|---|---|---|---|---|---|---|
| 16 | 15.89 | 7/1.70 | 5.1 | 43 | 2.84 | 1.8022 | 83 |
| 25 | 24.25 | 7/2.10 | 6.3 | 66 | 4.17 | 1.181 | 108 |
| 35 | 34.36 | 7/2.50 | 7.5 | 94 | 5.78 | 0.8333 | 134 |
| 50 | 49.48 | 7/3.00 | 9 | 135 | 7.94 | 0.5787 | 168 |
| 50 | 48.35 | 19/1.80 | 9 | 133 | 8.45 | 0.5951 | 166 |
| 70 | 65.81 | 19/2.10 | 10.5 | 181 | 11.32 | 0.4372 | 200 |
| 95 | 93.27 | 19/2.50 | 12.5 | 256 | 15.68 | 0.3085 | 248 |
| 120 | 116.99 | 19/2.80 | 14 | 322 | 18.78 | 0.2459 | 285 |
| 150 | 147.11 | 37/2.25 | 15.8 | 406 | 25.3 | 0.196 | 328 |
| 185 | 181.62 | 37/2.50 | 17.5 | 500 | 30.54 | 0.1588 | 373 |
| 240 | 242.54 | 61/2.25 | 20.3 | 670 | 39.51 | 0.1191 | 445 |
| 300 | 299.43 | 61/2.50 | 22.5 | 827 | 47.7 | 0.0965 | 506 |
| 400 | 400.14 | 61/2.89 | 26 | 1104 | 60.86 | 0.0722 | 602 |
| 500 | 499.83 | 61/3.23 | 29.1 | 1379 | 74.67 | 0.0578 | 688 |
| 625 | 626.2 | 91/2.96 | 32.6 | 1732 | 95.25 | 0.0462 | 786 |
| 800 | 802.09 | 91/3.35 | 36.9 | 2218 | 118.39 | 0.036 | 907 |
| 1000 | 999.71 | 91/3.74 | 41.1 | 2767 | 145.76 | 0.0289 | 1026 |
| Code | Nominal Area (mm^2) | Stranding (No.x mm) | Overall Diameter (mm) | Weight (kg/km) | Rated Strength (KN) | Electrical Resistance (Ω/Km) | Current Rating (A) |
|---|---|---|---|---|---|---|---|
| 10 | 10 | 7/1.35 | 4.05 | 27.4 | 1.95 | 2.8633 | 62 |
| 16 | 16 | 7/1.71 | 5.13 | 43.8 | 3.04 | 1.7896 | 84 |
| 25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 | 110 |
| 40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 | 147 |
| 63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.39 | 0.4545 | 195 |
| 100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 | 259 |
| 125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.25 | 0.2302 | 297 |
| 160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 | 345 |
| 200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 | 396 |
| 250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 | 454 |
| 315 | 315 | 37/3.29 | 23.03 | 867.9 | 51.97 | 0.0916 | 522 |
| 400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 | 603 |
| 450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 | 647 |
| 500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 | 688 |
| 560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 | 736 |
| 630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 | 789 |
| 710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 | 845 |
| 800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 | 905 |
| 900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 | 967 |
| 1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 | 1026 |
| 1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 | 1091 |
| 1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 | 1157 |
| 1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 | 1226 |
| 1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 | 1270 |
| Conductor codename | Stranding and wire diameter (no/mm) | Nominal overall diameter (mm) | Cross-sectional area (mm2) | Approximate mass (kg/km) | Breaking load (kN) | Modulus of elasticity (GPa) | Coefficient of linear expansion (x 10-6/°C) | DC resist. at 20°C (Ω/km) | AC resist. at 50Hz (Ω/km) |
|---|---|---|---|---|---|---|---|---|---|
| Leo | 7/2.50 | 7.5 | 34.4 | 94.3 | 5.71 | 65 | 23 | 0.833 | 1.02 |
| Leonids | 7/2.75 | 8.25 | 41.6 | 113 | 6.72 | 65 | 23 | 0.689 | 0.842 |
| Libra | 7/3.00 | 9 | 49.5 | 135 | 7.98 | 65 | 23 | 0.579 | 0.707 |
| Mars | 7/3.75 | 11.3 | 77.3 | 211 | 11.8 | 65 | 23 | 0.37 | 0.452 |
| Mercury | 7/4.50 | 13.5 | 111 | 304 | 16.9 | 65 | 23 | 0.258 | 0.315 |
| Lună | 7/4.75 | 14.3 | 124 | 339 | 18.9 | 65 | 23 | 0.232 | 0.284 |
| Neptune | 19/3.25 | 16.3 | 158 | 433 | 24.7 | 65 | 23 | 0.183 | 0.224 |
| Orion | 19/3.50 | 17.5 | 183 | 503 | 28.7 | 65 | 23 | 0.157 | 0.192 |
| Pluto | 19/3.75 | 18.8 | 210 | 576 | 31.9 | 65 | 23 | 0.137 | 0.168 |
| Saturn | 37/3.00 | 21 | 262 | 721 | 42.2 | 64 | 23 | 0.11 | 0.135 |
| Sirius | 37/3.25 | 22.8 | 307 | 845 | 48.2 | 64 | 23 | 0.094 | 0.116 |
| Taurus | 19/4.75 | 23.8 | 337 | 924 | 51.3 | 65 | 23 | 0.0857 | 0.105 |
| Triton | 37/3.75 | 26.3 | 409 | 1120 | 62.2 | 64 | 23 | 0.0706 | 0.0872 |
| Uranus | 61/3.25 | 29.3 | 506 | 1400 | 75.2 | 64 | 23 | 0.0572 | 0.071 |
| Ursula | 61/3.50 | 31.5 | 587 | 1620 | 87.3 | 64 | 23 | 0.0493 | 0.0616 |
| Venus | 61/3.75 | 33.8 | 673 | 1860 | 97.2 | 64 | 23 | 0.0429 | 0.0539 |
| Nominal Cross-section (mm2) | Number of Wires | Wire Diameter (mm) | Calculated Cross-section (mm2) | Overall Diameter (mm) | D.C. Resistance at 20 (Ω/km) | Min. Breaking Load | Conductor Weight (kg/km) | Greutate grăsime (kg/km) |
|---|---|---|---|---|---|---|---|---|
| 10 | 7 | 1.35 | 10.0 | 4.05 | 2.8631 | 1950 | 27.4 | - |
| 16 | 7 | 1.70 | 15.9 | 5.10 | 1.8007 | 3021 | 43.0 | 0.5 |
| 25 | 7 | 2.13 | 24.9 | 6.40 | 1.1498 | 4500 | 68.0 | 0.5 |
| 35 | 7 | 2.50 | 34.3 | 7.50 | 0.8347 | 5913 | 94.0 | 0.5 |
| 40 | 7 | 2.70 | 40.0 | 8.09 | 0.7157 | 6800 | 109.4 | - |
| 50 | 7 | 3.00 | 49.5 | 9.00 | 0.5784 | 8198 | 135.0 | 0.5 |
| 63 | 7 | 3.39 | 63.0 | 10.16 | 0.4544 | 10390 | 172.3 | - |
| 70 | 7 | 3.55 | 69.3 | 10.70 | 0.4131 | 11288 | 189.0 | 1.0 |
| 95 | 7 | 4.10 | 92.4 | 12.30 | 0.3114 | 14784 | 252.0 | 1.0 |
| 100 | 19 | 2.59 | 100.0 | 12.94 | 0.2877 | 17000 | 274.9 | - |
| 120 | 19 | 2.80 | 117.0 | 14.00 | 0.2459 | 19890 | 321.0 | 16 |
| 125 | 19 | 2.89 | 125.0 | 14.47 | 0.2301 | 21250 | 343.6 | - |
| 150 | 19 | 3.15 | 148.0 | 15.80 | 0.1944 | 24420 | 406.0 | 20 |
| 160 | 19 | 3.27 | 160.0 | 16.37 | 0.1798 | 26400 | 439.8 | - |
| 185 | 19 | 3.50 | 182.8 | 17.50 | 0.1574 | 29832 | 502.0 | 25 |
| 200 | 19 | 3.66 | 200.0 | 18.30 | 0.1438 | 32000 | 549.7 | - |
| 240 | 19 | 4.00 | 238.7 | 20.00 | 0.1205 | 38192 | 655.0 | 33 |
| 250 | 19 | 4.09 | 250.0 | 20.47 | 0.1150 | 40000 | 687.1 | - |
| 300 | 37 | 3.15 | 288.3 | 22.10 | 0.1000 | 47569 | 794.0 | 54 |
| 315 | 37 | 3.29 | 315.0 | 23.05 | 0.0915 | 51970 | 867.5 | - |
| 350 | 37 | 3.45 | 345.8 | 24.20 | 0.0833 | 57057 | 952.0 | 65 |
| 400 | 37 | 3.66 | 389.2 | 25.60 | 0.0740 | 63420 | 1072.0 | 73 |
| 450 | 37 | 3.90 | 449.1 | 27.30 | 0.0642 | 71856 | 1206.0 | 84 |
| 500 | 37 | 4.15 | 500.4 | 29.10 | 0.0576 | 80000 | 1378.0 | 94 |
| 550 | 61 | 3.37 | 544.0 | 30.30 | 0.0529 | 89760 | 1500.0 | 117 |
| 560 | 37 | 4.39 | 560.0 | 30.73 | 0.0531 | 89600 | 1542.2 | - |
| 600 | 61 | 3.50 | 586.8 | 31.50 | 0.0491 | 95632 | 1618.0 | 126 |
| 630 | 61 | 3.63 | 630.0 | 32.64 | 0.0458 | 100800 | 1738.4 | - |
| 650 | 61 | 3.66 | 641.7 | 32.90 | 0.0450 | 104575 | 1771.0 | 138 |
| 700 | 61 | 3.80 | 691.7 | 34.20 | 0.0417 | 112725 | 1902.0 | 149 |
| 710 | 61 | 3.85 | 710.0 | 34.65 | 0.0406 | 113600 | 1959.2 | - |
| 750 | 61 | 3.95 | 747.4 | 35.60 | 0.0386 | 119584 | 2062.0 | 161 |
| Nominal Cross-section (mm2) | Number of Wires | Wire Diameter (mm) | Calculated Cross-section (mm2) | Overall Diameter (mm) | D.C. Resistance at 20 (Ω/km) | Min. Breaking Load | Conductor Weight (kg/km) |
|---|---|---|---|---|---|---|---|
| 10 | 7 | 1.35 | 10.0 | 4.05 | 2.8631 | 1950 | 27.4 |
| 16 | 7 | 1.70 | 15.9 | 5.10 | 1.8007 | 3021 | 43.0 |
| 25 | 7 | 2.13 | 24.9 | 6.40 | 1.1498 | 4500 | 68.0 |
| 35 | 7 | 2.50 | 34.3 | 7.50 | 0.8347 | 5913 | 94.0 |
| 40 | 7 | 2.70 | 40.0 | 8.09 | 0.7157 | 6800 | 109.4 |
| 50 | 7 | 3.00 | 49.5 | 9.00 | 0.5784 | 8198 | 135.0 |
| 63 | 7 | 3.39 | 63.0 | 10.16 | 0.4544 | 10390 | 172.3 |
| 70 | 7 | 3.55 | 69.3 | 10.70 | 0.4131 | 11288 | 189.0 |
| 95 | 7 | 4.10 | 92.4 | 12.30 | 0.3114 | 14784 | 252.0 |
| 100 | 19 | 2.59 | 100.0 | 12.94 | 0.2877 | 17000 | 274.9 |
| 120 | 19 | 2.80 | 117.0 | 14.00 | 0.2459 | 19890 | 321.0 |
| 125 | 19 | 2.89 | 125.0 | 14.47 | 0.2301 | 21250 | 343.6 |
| 150 | 19 | 3.15 | 148.0 | 15.80 | 0.1944 | 24420 | 406.0 |
| 160 | 19 | 3.27 | 160.0 | 16.37 | 0.1798 | 26400 | 439.8 |
| 185 | 19 | 3.50 | 182.8 | 17.50 | 0.1574 | 29832 | 502.0 |
| 200 | 19 | 3.66 | 200.0 | 18.30 | 0.1438 | 32000 | 549.7 |
| 240 | 19 | 4.00 | 238.7 | 20.00 | 0.1205 | 38192 | 655.0 |
| 250 | 19 | 4.09 | 250.0 | 20.47 | 0.1150 | 40000 | 687.1 |
| 300 | 37 | 3.15 | 288.3 | 22.10 | 0.1000 | 47569 | 794.0 |
| 315 | 37 | 3.29 | 315.0 | 23.05 | 0.0915 | 51970 | 867.5 |
| 350 | 37 | 3.45 | 345.8 | 24.20 | 0.0833 | 57057 | 952.0 |
| 400 | 37 | 3.66 | 389.2 | 25.60 | 0.0740 | 63420 | 1072.0 |
| 450 | 37 | 3.90 | 449.1 | 27.30 | 0.0642 | 71856 | 1206.0 |
| 500 | 37 | 4.15 | 500.4 | 29.10 | 0.0576 | 80000 | 1378.0 |
| 550 | 61 | 3.37 | 544.0 | 30.30 | 0.0529 | 89760 | 1500.0 |
| 560 | 37 | 4.39 | 560.0 | 30.73 | 0.0531 | 89600 | 1542.2 |
| 600 | 61 | 3.50 | 586.8 | 31.50 | 0.0491 | 95632 | 1618.0 |
| 630 | 61 | 3.63 | 630.0 | 32.64 | 0.0458 | 100800 | 1738.4 |
| 650 | 61 | 3.66 | 641.7 | 32.90 | 0.0450 | 104575 | 1771.0 |
| 700 | 61 | 3.80 | 691.7 | 34.20 | 0.0417 | 112725 | 1902.0 |
| 710 | 61 | 3.85 | 710.0 | 34.65 | 0.0406 | 113600 | 1959.2 |
| 750 | 61 | 3.95 | 747.4 | 35.60 | 0.0386 | 119584 | 2062.0 |
-
Procese de producție ale conductoarelor goale aeriene
JOCA operează o linie de producție digitalizată special pentru fabricarea conductoarelor goale deasupra capului. Fluxul procesului începe cu inspecția tijei de aluminiu brut, deplasându-se prin trefilarea de mare viteză a sârmei și eșuarea de precizie într-un singur mediu urmărit de date. Pentru a preveni defectele, am integrat senzori inteligenți care monitorizează diametrul și netezimea suprafeței fiecărui strat de conductor în timp real. Această configurație automată utilizează tehnologia de măsurare cu laser pentru a impune respectarea strictă a standardelor ASTM, IEC și BS. Prin eliminarea variabilității manuale, sistemul asigură că fiecare bobină de AAC, AAAC sau ACSR menține o rezistență constantă la tracțiune și o performanță electrică stabilă, chiar și la o expunere extremă a mediului.
Ambalare pentru expediere
Pentru a satisface diverse nevoi de transport, există multe metode de ambalare care pot fi utilizate.
Ai mai multe întrebări?
Î: Ce face AAC diferit de ACSR?
A: It really comes down to the core material. AAC is 100% aluminum—super light and great for conductivity, but it isn’t built for high tension. ACSR, on the other hand, has that steel center to handle the heavy pulling over long distances.
Î: Pot folosi AAC pentru acele deschideri foarte lungi între turnuri?
A: Honestly? Not a good idea. Pure aluminum tends to sag too much when the gap is wide. If you’ve got a long span, go with ACSR or even AAAC instead. You need that extra mechanical “backbone.”
Q: Is the 1350 aluminum actually 99.5% pure?
A: Exactly. We stick to a minimum 99.5% purity. It’s the “sweet spot” for overhead lines—conducts electricity efficiently while staying flexible enough so the wire doesn’t snap during stranding.
Q: Will it hold up near the ocean?
A: Yes, it’s surprisingly tough against salt air. Aluminum forms a natural oxide skin that blocks corrosion. In high-humidity coastal spots, AAC (and AAAC) usually outlasts steel-based cables.
Q: What's the maintenance schedule like?
A: Very low-key. Once they’re up on the poles, you can mostly forget about them. The metal resists oxidation on its own, so there’s no need for constant checkups.
Q: How do you guys pack these for shipping?
A: We use standard treated wooden reels. They are sealed tight to stop any scratches or “pre-oxidation” before the cable even gets to your site. It arrives ready for the crew to pull.
Q: Can I install these in city networks or just rural areas?
A: They work fine for both, but AAC is a favorite for urban distribution where the spans are shorter and you want to keep the weight on the poles as low as possible.
Q: Need a quote or more specs?
A: Best way is to hit the “Contact Us” button right here. Or, just jump over to our profile and send a direct message. Our tech team usually gets back to people pretty quick.