NYCWY / NAYCWY

0.6/1kV Multi-Core PVC Insulated Power Cable with corrugated concentric conductors and PVC Sheath

  • Copper / Aluminum conductor

  • PVC insulation + PVC outer sheath

  • Rated voltage 0.6/1kV

  • corrugated concentric conductors

  • Copper Tape

  • Used for energy supply in power stations, subscriber networks, and for underground/outdoor installations. Also capable of handling control impulses and test data.

 Economisiți cel puțin 30% în medie

NYCWY_NAYCWY
  • pictogramă

    Descrierea produsului

    NYCWY / NAYCWY Power Cable : Product Description and Specifications

The NYCWY / NAYCWY concentric conductor power cables serve as a robust solution for underground energy distribution and subscriber networks. Specific, they efficiently power industrial facilities, meter tails, and systems requiring enhanced protection. În plus, designul caracteristici a concentric copper conductor (CW) that funcții as an earth, neutral, or protective path. Mai mult, this configuration actively delivers superior fault current withstand capability. În consecinţă, the cable ensures improved EMC shielding and reliable electrical performance.

NYCWY_NAYCWY_1
  • pictogramă

    Avantaje

    NYCWY / NAYCWY Power Cable : Benefits and Features

  • Enhanced Protection: This cable design increases electrical and mechanical protection, making it ideal for demanding applications where both are essential.

  • Durabilitate: The use of a corrugated concentric conductor (CW) significantly boosts the cable’s reliability and longevity, even in harsh environments.

  • Fiabilitate: Thanks to its unique construction, the cable delivers dependable performance and ensures a high level of operational reliability.

  • Easy Installation and Maintenance: This cable’s design simplifies the installation process by allowing multiple cable joints without cutting any conductor, streamlining maintenance.

  • Versatile Usage: The cable functions as a neutral, protective, or earth conductor, offering flexibility in various configurations.

Specification Of NYCWY / NAYCWY Power Cable

Technical Data ParameterTechnical Data Value
Conductor resistance at 20°C:according to VDE 0295 and IEC 60228
Core temperature, max:70°C in operation
Max. short circuit temperature:160°C , not more than 5 sec
Rated voltage - U0 /U (Umax):0.6/1(1.2) kV
Test voltage:AC - 4 kV; 50 Hz
Interval de temperatură
Fixed installation:-30°C to +70°C
Flexible Installation:-5°C to +50°C
Bending radius, min.12xD cable
pecific insulation resistance at 70°C:min, 1010 Ωx cm
ssible tensile stress with cable grip:For Cu conductor = 50 N/mm2 For Al conductor = 30 N/mm2
Cable Structure ComponentCable Structure Description
Dirijor:solid or multi-strand Cu or Al wires class 1, 2 or 5 acc. VDE 0295(IEC 60228)
Izolație:PVC type DIV4 acc. VDE0207
Core identification:according to VDE 0293 (HD 308)
Cores assembly:cores stranded concentrically (cores stranded in concentric layers, for signal)
Inner sheath:rubber filling compaund
Concentric copper conductor:Waveconal outer conductor - copper wires and contrahelical copper tape (reverse lay copper tape)
Teaca:PVC type DMV5 acc. VDE 0207

Dimensiuni/Parametri

Number of cores x Nominal Cross Section (No x mm²)Overall Diameter Approx. (max.mm)Copper weight Approx. (kg/km)Total Weight Approx. (kg/km)
3x10/1020394.0775.0
3x16/1622.0630.01066.0
3x25/1626.0895.01584.0
3x35/16281190.01710.0
3x50/2530.01722.02368.0
3x70/3533.02411.03174
3x95/5038.03296.04256.0
3x120/7041.04231.05314.0
3x150/7045.05117.06344.0
3x185/9550.06396.08054.0
3x240/12056.08265.010274.0
4x10/1021.0492.0897.0
4x16/1624.0787.01250.0
4x25/1628.01141.01822.0
4x35/1629.01535.02140.0
4x50/2533.02214.03031.0
4x70/3538.03100.04056.0
4x95/5043.04231.05364.0
4x120/7046.05412.06748.0
4x150/7051.06592.08159.0
4x185/9557.08216.010198.0
  • pictogramă

    Production Processes Of Power Cable

To ensure superior quality, JOCA operates fully digitalized and automated production lines for cabluri alimentare. Specific, this comprehensive workflow covers conductor stranding, insulation extrusion, metallic screening, and final sheathing. Mai mult, intelligent systems actively monitor each stage to ensure stable performance and consistent product quality. În plus, the factory utilizes advanced testing facilities, such as partial discharge testing, tensile testing, and spark testing. În consecinţă, these rigorous measures guarantee that every delivered cable strictly meets international standards.

Procese de producție a sârmei fotovoltaice

Ambalare pentru expediere

Pentru a satisface diverse nevoi de transport, există multe metode de ambalare care pot fi utilizate.

ambalare cablu de alimentare

Ai mai multe întrebări?

Am compilat mai jos cele mai frecvente întrebări referitoare la specificații, standarde de siguranță și aplicații Dacă nu vedeți ce căutați sau aveți o cerință personalizată specifică, trebuie doar să contactați direct echipa noastră de ingineri.

Q: What is the primary application for these cables?

A: These are the backbone of Low Voltage distribution networks (0.6/1kV). They are specifically designed for municipal power supply, subscriber networks, and power stations where you need a robust underground cable that also offers interference shielding.

 

Q: What makes the "CW" (Corrugated Concentric) conductor special?

A: This is the key feature. Unlike standard straight copper wires, the “CW” conductor is applied in a wave (Ceander) pattern. This allows installers to spread the outer wires apart to access the inner cores without cutting the neutral/earth conductor. It makes creating branch connections (T-joints) much faster and safer, especially for house service connections.

 

Q: Where can I install them?

A: They are versatile. You can bury them directly underground, lay them in concrete cable ducts, submerge them in water, or run them indoors. The PVC sheath is built to handle open-air environments as well, provided it’s not subjected to constant mechanical impact.

 

Q: Does it act as a protective screen?

A: Yes. The concentric copper layer acts as a combined PE or PEN conductor. Additionally, because it surrounds the phase conductors, it provides an effective earthed screen against accidental contact. If a digger hits the cable, it hits the earth screen first, tripping the protection instantly.

 

Q: How does it compare to standard NYY cables?

A: It offers higher safety and functionality. While NYY is just insulated power, this cable (likely NYCWY) adds that concentric conductor layer. This provides better mechanical protection and necessary shielding for control impulses or data if run nearby.

 

 

Q: What is the reliability advantage for jointing?

A: As mentioned, the ability to make joints without cutting the conductor is a game-changer for grid reliability. Every time you cut a neutral to make a joint, you introduce a potential failure point. The CW design eliminates that risk, ensuring the neutral path remains solid and continuous.

Q: What are the voltage and standard ratings?

A: These are rated for 0.6/1 kV and manufactured in strict accordance with DIN VDE 0276-603 și IEC 60502-1.

 

Q: How do I get a quote or technical datasheet?

A: Send us your project requirements directly. We need to know the cross-section (e.g., 4×150/70), drum length, and whether you need the Ceander (CW) or standard concentric design. Our engineering team will return a spec sheet and offer within 24 hours.