Technical Specifications :
- Cable Shape: Flat (3-Core / 4-Core)
- 電圧定格: 0.6/1kV (High Voltage Rating)
- 指揮者: Class 5 Flexible Tinned Copper (Corrosion Resistant)
- 絶縁: High-Grade EPR (Type 3GI3)
- シース: Water Resistant Rubber (Type EM2)
- Operating Temperature: -40°C to +90°C
- Max. Water Temp: Up to +60°C (Submerged)
- 曲げ半径: 3x Cable Height (Extremely Flexible)
- 耐水性: IP68 / AD8 (Permanent Submersion)
- カスタマイズされたソリューションによる高速サンプル処理
- 高品質な素材
- 手頃な価格のオプション
- グローバル デリバリー
- より良いデータ保護のために、すべてのアップロードが安全であることを確認してください
平均で少なくとも30%を保存します
-
製品の説明
Submersible Cable : Product Description and Specifications
Deep well casings leave zero margin for bulky wiring. The JOCA Flat Submersible Cable is engineered specifically for this space constraint. Its low-profile flat geometry slides effortlessly between the pump riser and the borehole wall, preventing the “snagging” and jacket abrasion common with round cables.
Internally, we utilize Tinned Electrolytic Copper (Class 5 flexible) rather than bare copper. This tin layer is critical—it stops the conductors from turning black (oxidizing) in high-humidity environments. The core is sealed inside a specialized water-resistant Rubber or EPR compound, tested to withstand massive hydrostatic pressure at depths up to 300 meters. Rated for 0.6/1kv power systems and compliant with IEC 60245, this cable guarantees a permanent, watertight link for submersible pumps in drinking water or industrial drainage wells.
-
利点
Submersible Cable : Benefits and Features
Fits Narrow Boreholes: の The flat, low-profile geometry slides easily into tight casings without scraping the walls or jamming the pump.
Stops “Black Copper”: 私たちは使用します fully tinned conductors to block oxidation. The wire stays bright and conductive, even after years in humid, underwater conditions.
Long-Distance Power: に 評価 0.6/1kv, it handles the voltage drop of deep-well transmission without overheating or power loss.
Potable Water Safe: The jacket uses non-toxic, food-grade rubber compounds, certified safe for drinking water pumps and eco-sensitive wells.
Zero Leakage: The pressure-tested sheath forms an impermeable barrier against water ingress, even at hydrostatic pressures up to 300m depth.
寸法/パラメータ
| No. of Cores | Nominal Cross Sectional Area (mm²) | Nominal Diameter of Conductor (mm) | Height Min (mm) | Height Max (mm) | Width Min (mm) | Width Max (mm) | Nominal Weight (kg/km) | Maximum Tensile Load (N) |
|---|---|---|---|---|---|---|---|---|
| 3 | 4 | 2.4 | 7.0 | 8.0 | 15.5 | 16.5 | 260 | 180 |
| 3 | 6 | 2.9 | 7.5 | 8.5 | 17.5 | 18.5 | 330 | 270 |
| 3 | 10 | 3.8 | 10.3 | 11.0 | 23.1 | 24.1 | 550 | 450 |
| 3 | 16 | 4.9 | 12.2 | 13.2 | 28.0 | 29.5 | 820 | 720 |
| 3 | 25 | 6.1 | 14.2 | 15.2 | 33.0 | 34.5 | 1180 | 1125 |
| 3 | 35 | 7.2 | 16.0 | 17.5 | 37.0 | 38.7 | 1560 | 1575 |
| 3 | 50 | 8.9 | 18.5 | 20.0 | 44.1 | 45.8 | 2190 | 2250 |
| 3 | 70 | 10.6 | 20.5 | 22.0 | 50.5 | 52.5 | 2890 | 3150 |
| 3 | 95 | 12.3 | 23.1 | 23.9 | 57.1 | 57.9 | 3610 | 4275 |
| 3 | 120 | 14.2 | 25.1 | 25.9 | 62.1 | 62.9 | 4420 | 5400 |
| 3 | 150 | 15.5 | 26.8 | 27.6 | 67.2 | 68.0 | 5370 | 6750 |
| 3 | 185 | 17.0 | 28.6 | 29.4 | 72.6 | 73.4 | 6440 | 8325 |
| 4 | 4 | 2.4 | 8.0 | 9.0 | 23.0 | 24.0 | 400 | 240 |
| 4 | 6 | 2.9 | 8.5 | 9.5 | 24.5 | 25.5 | 490 | 360 |
| 4 | 10 | 3.8 | 10.0 | 11.0 | 29.5 | 30.5 | 710 | 600 |
| 4 | 16 | 4.9 | 12.0 | 13.0 | 34.5 | 35.5 | 1040 | 960 |
| 4 | 25 | 6.1 | 15.8 | 17.2 | 42.1 | 43.5 | 1660 | 1500 |
| 4 | 35 | 7.2 | 18.6 | 19.4 | 48.6 | 49.8 | 2190 | 2100 |
| 4 | 50 | 8.9 | 19.4 | 20.2 | 56.8 | 57.6 | 2880 | 3000 |
| 4 | 70 | 10.6 | 24.0 | 24.8 | 65.4 | 66.6 | 4060 | 4200 |
| 4 | 95 | 12.3 | 25.6 | 26.4 | 73.0 | 74.2 | 5050 | 5700 |
| 4 | 120 | 14.2 | 28.3 | 29.1 | 83.8 | 85.0 | 5580 | 7200 |
-
Production Processes Of Rubber cable
JOCA produces these cables using Continuous Vulcanization (CV) technology. This automated system synchronizes copper stranding with rubber extrusion, allowing the EPR insulation そして PCP outer sheath to cure evenly. This integrated process ensures a consistent, solid bond between layers without structural defects. regarding quality control, we perform routine oil immersion and flexibility tests on production batches to verify compliance with IEC 60245 and EN 50525.
配送用梱包
さまざまな輸送ニーズを満たすために、使用できる梱包方法は数多くあります。.
もっと質問がありますか?
Q: なぜ丸いのではなく平らなのですか?
A: クリアランス. Round cables jam in tight casings. Flat cables don’t. They slide past the pump riser without rubbing against the borehole wall. No friction, no snagging.
Q: 本当の深さの評価か?
A: 300メートル(30バール). 高密度ゴムコンパウンドを使用しています。水の侵入を物理的にブロックし、大量の静水圧下でも永久断熱を確保します。.
Q: 塩水と下水は安全ですか?
A: はい ジャケットは化学的に不活性です 扱います 塩水、消化酸、汚泥. Unlike cheap rubber, this material won’t swell or rot in wastewater tanks.
Q: なぜ錫メッキ銅ですか?
A: 殺すこと “Black Copper” (oxidation). 裸線は黒く、湿気で失敗します。 tinningはポンプの生命のために明るいおよび伝導性の鎖を保ちます。.
Q: 電圧限界か?
A: 0.6/1kv. モーターの始動スパイクに対応するように構築されています。ディープウェルポンプ運転中に低定格ケーブルを焼き切る電圧ストレスに耐えます。.
Q: 臨時雇用者の範囲か?
A:
空気: -40° Cから+90° C.
水: 最高+60° C。 (熱水はゴム老化を早めますので、長寿のために60° C未満でいることをお勧めします)。.
Q: シースは硬いですか?
A: ドラッグしてください。乱用用に作られています。頑丈なジャケットは、岩だらけの井戸の壁やケーシングの鋭い端に引き寄せられた場合でも、引き裂きに強いです。.
Q: サイジングの目安?
A: ウォッチ ザ 電圧降下. Long vertical runs kill voltage. Don’t just match the Amps; calculate for a <3%ドロップ モーター端子で。 疑わしいときは、1 サイズ太くしてください。.