Bloqueador de fraude

JOCA

N2XSR(AL)Y/NA2XSR(AL)Y

3.6 KV-35 KV Único XLPE Fio de alumínio de isolamento Cabo de alimentação blindado e PVC Jacket

  • Condutor: Cobre ou Alumínio (Classe 2 de acordo com IEC 60502-2).
  • Isolamento : XLPE
  • Tela Metálica : Fita de cobre
  • Camada Separação : Fita não higroscópica. 
  • Bainha Interior : PVC
  • Armadura : Aluminum Wire Armor (AWA).
  • Bainha Externa : PVC 
  • Cor : Geralmente Vermelho ou Preto.

 Economize pelo menos 30% em média

N2XSR(AL)Y-NA2XSR(AL)Y
  • ícone

    Descrição do produto

    N2XSR(AL)Y/NA2XSR(AL)Y : Product Description and Specifications

O N2XSR(AL)Y e NA2XSR(AL)Y series are engineered for Núcleo Único Medium Voltage applications (3.6kV–35kV). Crucially, the mechanical protection system utilizes Aluminum Wire Armor (AWA) instead of steel. Since steel generates magnetic heating (eddy currents) in single-core AC circuits, the non-magnetic AWA design eliminates this thermal risk. Simultaneously, the ‘Wire’ construction provides the longitudinal tensile strength required for vertical runs, distinct from tape-armored alternatives. The core is insulated with high-grade XLPE and finished with a weather-resistant PVC sheath.

N2XSR(AL)Y-NA2XSR(AL)Y_1
  • ícone

    Vantagens

    N2XSR(AL)Y/NA2XSR(AL)Y : Benefits and Features

  • Magnetic Neutrality (AWA): For single-core AC applications, Steel armor is strictly prohibited as it causes magnetic induction heating. We use Armadura de fio de alumínio (AWA) to eliminate this eddy current risk while maintaining mechanical crush resistance. 

  • Thermal Headroom: The XLPE insulation system is rated for 90°C continuous operation. This offers a significantly higher safety margin against thermal overload compared to standard thermoplastic limits. 

  • Tensile Capability: Unlike tape armor, the “Wire” construction provides the longitudinal tensile strength necessary for vertical installations or high-tension pulls. 

  • Screening Logic: A Fita Cobre metallic screen is applied to control electrical field stress and provide a fault current path, encased in a Type ST2 PVC sheath for environmental sealing. 

Dimensões/Parâmetros

3.6/6 kv Single XLPE Insulation Aluminum Wire Armoured and PVC Jacket power
Nome. Seita Cruzada. (mm2)Conductor DC Resistance at 20°C (Ω/km)Conductor AC Resistance at 90°C (Ω/km)Indutância Formação de trevo (mH/km)Indutância Formação plana (mH/km)Current Capacity Trefoil in air (A)Current Capacity Trefoil in ground (A)Current Capacity Flat in air (A)Current Capacity Flat in ground (A)Short circuit current Conductor (kA)Short circuit current Screen (kA)
250.7270.9270.4510.4981671541711573.581.14
350.5240.6680.4280.4742021842071885.011.14
500.3870.4940.4100.4572412162462217.151.14
700.2680.3420.3860.43230026430626910.011.14
950.1930.2470.3710.41736331337031813.591.14
1200.1530.1960.3570.40341735542435917.161.14
1500.1240.1590.3450.39147139547839921.451.14
1850.09910.1280.3340.38053644254344526.461.14
2400.07540.0980.3300.37662550162749934.321.14
3000.06010.0790.3230.36970655570555042.901.14
4000.04700.0630.3120.35880561779760757.201.14
5000.03660.0500.3120.35889466387764571.501.14
6300.02830.0410.3020.34899372096769590.091.14
6/10 kv Single XLPE Insulation Aluminum Wire Armoured and PVC Jacket power​
Nome. Seita Cruzada. (mm2)Conductor DC Resistance at 20°C (Ω/km)Conductor AC Resistance at 90°C (Ω/km)Indutância Formação de trevo (mH/km)Indutância Formação plana (mH/km)Current Capacity Trefoil in air (A)Current Capacity Trefoil in ground (A)Current Capacity Flat in air (A)Current Capacity Flat in ground (A)Short circuit current Conductor (kA)Short circuit current Screen (kA)
250.7270.9270.4670.5131691541721573.581.14
350.5240.6680.4430.4892041842091875.011.14
500.3870.4940.4250.4712432162482207.151.14
700.2680.3420.4010.44730226330826810.011.14
950.1930.2470.3830.43036531337231813.591.14
1200.1530.1960.3690.41541935342635817.161.14
1500.1240.1590.3620.40947539248139621.451.14
1850.09910.1280.3530.39953843854344026.461.14
2400.07540.0980.3400.38662750062949834.321.14
3000.06010.0790.3290.37570655470554942.901.14
4000.04700.0630.3160.36380561679860657.201.14
5000.03660.0500.3130.36089566487864671.501.14
6300.02830.0410.3040.35099572196969590.091.14
8.7/15 kv Single XLPE Insulation Aluminum Wire Armoured and PVC Jacket power​
Nome. Seita Cruzada. (mm2)Conductor DC Resistance at 20°C (Ω/km)Conductor AC Resistance at 90°C (Ω/km)Indutância Formação de trevo (mH/km)Indutância Formação plana (mH/km)Current Capacity Trefoil in air (A)Current Capacity Trefoil in ground (A)Current Capacity Flat in air (A)Current Capacity Flat in ground (A)Short circuit current Conductor (kA)Short circuit current Screen (kA)
250.7270.9270.4850.5311701531741563.581.14
350.5240.6680.4610.5072061832111875.011.14
500.3870.4940.4420.4892452152502197.151.14
700.2680.3420.4170.46330426231026710.011.14
950.1930.2470.3980.44436731237331613.591.14
1200.1530.1960.3910.43742235142735417.161.14
1500.1240.1590.3770.42447739148239421.451.14
1850.09910.1270.3660.41254043754543826.461.14
2400.07540.0980.3510.39762849963049734.321.14
3000.06010.0790.3400.38670955370754842.901.14
4000.04700.0630.3340.38179960479059257.201.14
5000.03660.0500.3230.36989666388064571.501.14
6300.02830.0410.3130.35999772097169590.091.14
12/20 kv Single XLPE Insulation Aluminum Wire Armoured and PVC Jacket power​
Nome. Seita Cruzada. (mm2)Conductor DC Resistance at 20°C (Ω/km)Conductor AC Resistance at 90°C (Ω/km)Indutância Formação de trevo (mH/km)Indutância Formação plana (mH/km)Current Capacity Trefoil in air (A)Current Capacity Trefoil in ground (A)Current Capacity Flat in air (A)Current Capacity Flat in ground (A)Short circuit current Conductor (kA)Short circuit current Screen (kA)
350.5240.6680.4750.5212081832121865.011.14
500.3870.4940.4560.5022462152512197.151.14
700.2680.3420.4290.47630626231126610.011.14
950.1930.2470.4180.46537031037531413.591.14
1200.1530.1960.4030.44942335042935417.161.14
1500.1240.1590.3890.43547839048339321.451.14
1850.09910.1270.3770.42354143654543726.461.14
2400.07540.0980.3610.40763049863149634.321.14
3000.06010.0790.3550.40270754570353842.901.14
4000.04700.0620.3430.38980160479259257.201.14
5000.03660.0500.3310.37790066388464571.501.14
6300.02830.0400.3210.36799972197469590.091.14
18/30 kv Single XLPE Insulation Aluminum Wire Armoured and PVC Jacket power​
Nome. Seita Cruzada. (mm2)Conductor DC Resistance at 20°C (Ω/km)Conductor AC Resistance at 90°C (Ω/km)Indutância Formação de trevo (mH/km)Indutância Formação plana (mH/km)Current Capacity Trefoil in air (A)Current Capacity Trefoil in ground (A)Current Capacity Flat in air (A)Current Capacity Flat in ground (A)Short circuit current Conductor (kA)Short circuit current Screen (kA)
500.3870.4940.4950.5422502142542177.151.14
700.2680.3420.4670.51330926031426410.011.14
950.1930.2470.4460.49337230937731213.591.14
1200.1530.1960.4290.47542634943135217.161.14
1500.1240.1590.4150.46148038948539121.451.14
1850.09910.1270.4090.45554343154643126.461.14
2400.07540.0970.3920.43863049163048834.321.14
3000.06010.0780.3790.42670854270553642.901.14
4000.04700.0620.3630.41080460379659157.201.14
5000.03660.0500.3500.39690266288764571.501.14
6300.02830.0400.3400.386100472198169790.091.14
  • ícone

    Processos de produção de cabos de alimentação

Para assegurar a qualidade superior, JOCA opera linhas de produção totalmente digitalizadas e automatizadas para cabos alimentação. Especificamente, este fluxo de trabalho abrangente capas encalhe do condutor, extrusão da isolação, triagem metálica, e revestimento final. Além disso, sistemas inteligentes monitore ativamente cada etapa para garantir um desempenho estável e uma qualidade consistente do produto. Além disso, a fábrica utiliza instalações de teste avançadas, como testes de descarga parcial, testes de tração e testes de faísca. Consequentemente, estas medidas rigorosas garantia que cada cabo entregue cumpre restritamente padrões internacionais.

Processos de produção de fios fotovoltaicos

Embalagem para envio

Para atender a várias necessidades de transporte, existem muitos métodos de embalagem que podem ser usados.

embalagem do cabo de alimentação

Tem mais perguntas?

Comece facilmente encontrando as respostas para perguntas comuns sobre nossa empresa e serviços.

Q: Voltage Application?

 R: Full Medium Voltage spectrum: 3,6/6kV through 26/35kV.

 

Q: Why Aluminum Wire Armor (AWA) instead of Steel?

R: Physics constraint. Steel is magnetic and acts as an inductor on single-core AC circuits, causing overheating. AWA is non-magnetic, eliminating this eddy current risk while retaining mechanical tensile strength.

Q: Conductor options?

 R: Copper (N2XSR) for max ampacity, or Aluminum (NA2XSR) for weight/cost reduction.

 

Q: Function of the Copper Tape screen?

R: Field Stress Control. It manages radial electric fields and provides a calculated earth fault path.

Q: Insulation type?

R: XLPE. Chosen for its 90°C continuous thermal rating, far superior to legacy PVC limits (70°C).

 

Q: Outdoor installation?

R: Verified. The outer jacket utilizes UV-stabilized PVC (Type ST2), suitable for exposure or trench burial.

 

Q: Manufacturing Standard?

R: CEI 60502-2 (Class 2 Stranded Conductors).

 

Q: Sheath Colors?

R: Padrão: Vermelho ou Preto. (Black recommended for high UV zones).

 