SAC Cavo aereo distanziato in alluminio

SAC Aluminum Spaced Aerial Cable for Overhead Distribution Lines

  • Conduttore : Compact stranded hard drawn Aluminium wire.

  • Conductor shield : Semi-conducting cross-linked polyethylene.

  • Isolamento : Cross-linked polyethylene (Natural)

  • Guaina : Track resistant cross-linked polyethylene (Black)

 Risparmia almeno 30% in media

SAC Aluminum Spaced Aerial Cable_1
  • icona

    Descrizione del prodotto

    SAC Aluminum Spaced Aerial Cable : Product Description and Specifications

15kV Spaced Aerial Cable (SAC). Progettato appositamente per Overhead Distribution Networks on pole infrastructure.

Engineering Constitution: The assembly utilizes Compact Stranded Hard-Drawn Aluminum conductors to maximize longitudinal tensile modulus, minimizing sag on long spans. The dielectric layer features a specialized Black Track-Resistant XLPE sheath. This formulation is chemically engineered to stop electrical surface tracking and prevent UV degradation, ensuring operational stability in high-exposure outdoor environments.

SAC Cavo aereo distanziato in alluminio
  • icona

    Vantaggi

    SAC Aluminum Spaced Aerial Cable : Benefits and Features

  • Thermal Rating: 90 °C continuous / 250 °C short-circuit tolerance.

  • Insulation Physics: Black Track-Resistant XLPE. Engineered to inhibit electrical surface discharge in polluted zones.

  • Mechanical Structure: Compact Stranded Aluminum. Maximizes tensile strength and minimizes wind load.

  • Field Control: Integrated Semi-Conductive Shield ensures dielectric stability.

  • Environmental: Carbon-stabilized sheath. Impervious to UV radiation and weathering.

  • Installazione: Lightweight Profile. Reduces pole static load compared to standard bundled cables.

Specification Of SAC Aluminum Spaced Aerial Cable

15 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoriaParametroValore
Product InfoProduct Name15 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
ApplicazioneApplicazioneFor used in primary aerial cable on pole
ClassificazioneNormal Operation Temperature90 °C
ClassificazioneEmergency Overload Temperature130°C
ClassificazioneShort Circuit Temperature250 °C
ClassificazioneValutazione della tensione15 kV phase to phase
SperimentazioneAC Testing Voltage27 kV for 5 minutes
StandardReference StandardPDITL / MEA / PEA
CostruzioneConduttoreCompact stranded hard drawn Aluminium wire
CostruzioneConductor ShieldSemi-conducting cross-linked polyethylene
CostruzioneIsolamentoCross-linked polyethylene (Natural)
CostruzioneGuainaTrack resistant cross-linked polyethylene (Black)
25 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoriaParametroValore
Product InfoProduct Name25 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
ApplicazioneApplicazioneFor used in primary aerial cable on pole
ClassificazioneNormal Operation Temperature90 °C
ClassificazioneEmergency Overload Temperature130°C
ClassificazioneShort Circuit Temperature250 °C
ClassificazioneValutazione della tensione25 kV phase to phase
SperimentazioneAC Testing Voltage38 kV for 5 minutes
StandardReference StandardTIS 2341-2555 / MEA / PEA
CostruzioneConduttoreCompact stranded hard drawn Aluminium wire
CostruzioneConductor ShieldSemi-conducting cross-linked polyethylene
CostruzioneIsolamentoCross-linked polyethylene (Natural)
CostruzioneGuainaTrack resistant cross-linked polyethylene (Black)
35 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoriaParametroValore
Product InfoProduct Name35 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
ApplicazioneApplicazioneFor used in primary aerial cable on pole
ClassificazioneNormal Operation Temperature90 °C
ClassificazioneEmergency Overload Temperature130°C
ClassificazioneShort Circuit Temperature250 °C
ClassificazioneValutazione della tensione35 kV phase to phase
SperimentazioneAC Testing Voltage49 kV for 5 minutes
StandardReference StandardTIS 2341-2555 / MEA / PEA
CostruzioneConduttoreCompact stranded hard drawn Aluminium wire
CostruzioneConductor ShieldSemi-conducting cross-linked polyethylene
CostruzioneIsolamentoCross-linked polyethylene (Natural)
CostruzioneGuainaTrack resistant cross-linked polyethylene (Black)

Dimensioni/Parametri

15 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)
3566.91.911.9116.00.8681820151232
5068.01.911.9117.50.6411612187291
70129.81.911.9119.00.4431445231358
951511.41.911.9121.00.3201284281451
1201512.91.911.9122.50.2531152324552
1501514.11.911.9124.00.2061070375639
1853015.81.911.9125.50.164980433763
2403018.31.911.9128.00.125874525953
25 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)
3566.93.183.1821.00.8682580149363
5068.03.183.1822.00.6412314186432
70129.83.183.1824.50.4432100229509
951511.43.183.1826.00.3201887279615
1201512.93.183.1827.00.2531712321729
1501514.13.183.1829.50.2061600371826
1853015.83.183.1831.00.1641477429959
2403018.33.183.1833.50.12513285201170
35 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)Standard packing (m)
5068.04.453.1825.50.64126061845171000/R
70129.84.453.1827.50.44323752275991000/R
951511.44.453.1829.00.32021442767111000/R
1201512.94.453.1831.00.25319523188311000/R
1501514.14.453.1832.50.20618303679331000/R
1853015.84.453.1833.50.164169442510731000/R
2403018.34.453.1836.50.125152951512931000/R
  • icona

    Processi di produzione di cavi aerei raggruppati

L'infrastruttura di produzione di cavi aerei gestisce un sistema di automazione digitale a circuito chiuso, integrando l'incaglio dei conduttori, l'estrusione dell'isolamento e la guaina finale in un flusso di lavoro continuo La stabilità del processo si basa su matrici di sensori incorporati che tracciano i parametri di estrusione in tempo reale, eliminando le varianze manuali La convalida della qualità viene applicata attraverso hardware specifico in linea, inclusi misuratori di diametro laser a doppio asse e tester di scintille ad alta tensione, mentre il laboratorio fisico conduce analisi distruttive di trazione e allungamento per verificare la conformità agli standard internazionali prima della spedizione.

 

Processi di produzione del filo fotovoltaico

Imballaggio per la spedizione

Per soddisfare le varie esigenze di trasporto, ci sono molti metodi di imballaggio che possono essere utilizzati.

Imballaggio per la spedizione

Hai altre domande?

Abbiamo compilato le domande più comuni relative a specifiche, standard di sicurezza e applicazioni di seguito Se non vedi cosa stai cercando o hai un requisito personalizzato specifico, contatta direttamente il nostro team di ingegneri.

D: Applicazione primaria?

 A: Distribuzione aerea MV. Progettato come alternativa più sicura e isolata ai conduttori nudi sulle reti a palo.

 

D: Perché guaina "resistente alla traccia"?

 A: Vincolo Fisico. L'inquinamento e l'umidità creano percorsi di perdita (tracking) Il Xlpe nera la formulazione blocca fisicamente questi percorsi per prevenire i flashover.

 

Q: Luce solare/Esposizione esterna?

A: UV Immune. L'XLPE stabilizzato al carbonio garantisce stabilità operativa a lungo termine sotto radiazione solare diretta.

 

Q: Limite termico a corto circuito?

A: 250 °C. (Tolleranza massima per la durata del cortocircuito senza rottura dell'isolamento).

 

D: Uso costiero/industriale?

A: Verificato. La chimica anti-tracciamento agisce come una barriera contro la nebbia salina, la polvere chimica e l'elevata umidità.

 

D: Metodo di installazione?

A: Sistema distanziatore. Richiede distanziatori isolanti e staffe specifici per la manutenzione 15kV clearance fase-fase.

 

D: Come richiedere un preventivo?

A: Azione: Click the “Contattaci” button or view the Profilo Venditore directly for technical pricing.

Scorri fino in cima
Entra in contatto con la società JOCA

Compila gentilmente il modulo sottostante per contattarci. Miriamo a risponderti entro 12 ore. Ti auguro il meglio!

Contact Form Demo

JOCA