SAC Aluminum Spaced Aerial Cable for Overhead Distribution Lines

  • Conductor : Compact stranded hard drawn Aluminium wire.

  • Conductor shield : Semi-conducting cross-linked polyethylene.

  • Insulation : Cross-linked polyethylene (Natural)

  • Sheath : Track resistant cross-linked polyethylene (Black)

 Save at least 30% on average

SAC Aluminum Spaced Aerial Cable_1
  • icon

    Product Description

    SAC Aluminum Spaced Aerial Cable : Product Description and Specifications

15kV Spaced Aerial Cable (SAC). Designed specifically for Overhead Distribution Networks on pole infrastructure.

Engineering Constitution: The assembly utilizes Compact Stranded Hard-Drawn Aluminum conductors to maximize longitudinal tensile modulus, minimizing sag on long spans. The dielectric layer features a specialized Black Track-Resistant XLPE sheath. This formulation is chemically engineered to stop electrical surface tracking and prevent UV degradation, ensuring operational stability in high-exposure outdoor environments.

SAC Aluminum Spaced Aerial Cable
  • icon

    Advantages

    SAC Aluminum Spaced Aerial Cable : Benefits and Features

  • Thermal Rating: 90°C continuous / 250°C short-circuit tolerance.

  • Insulation Physics: Black Track-Resistant XLPE. Engineered to inhibit electrical surface discharge in polluted zones.

  • Mechanical Structure: Compact Stranded Aluminum. Maximizes tensile strength and minimizes wind load.

  • Field Control: Integrated Semi-Conductive Shield ensures dielectric stability.

  • Environmental: Carbon-stabilized sheath. Impervious to UV radiation and weathering.

  • Installation: Lightweight Profile. Reduces pole static load compared to standard bundled cables.

Specification Of SAC Aluminum Spaced Aerial Cable

15 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoryParameterValue
Product InfoProduct Name15 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
ApplicationApplicationFor used in primary aerial cable on pole
ClassificationNormal Operation Temperature90°C
ClassificationEmergency Overload Temperature130°C
ClassificationShort Circuit Temperature250°C
ClassificationVoltage Rating15 kV phase to phase
TestingAC Testing Voltage27 kV for 5 minutes
StandardsReference StandardPDITL / MEA / PEA
ConstructionConductorCompact stranded hard drawn Aluminium wire
ConstructionConductor ShieldSemi-conducting cross-linked polyethylene
ConstructionInsulationCross-linked polyethylene (Natural)
ConstructionSheathTrack resistant cross-linked polyethylene (Black)
25 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoryParameterValue
Product InfoProduct Name25 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
ApplicationApplicationFor used in primary aerial cable on pole
ClassificationNormal Operation Temperature90°C
ClassificationEmergency Overload Temperature130°C
ClassificationShort Circuit Temperature250°C
ClassificationVoltage Rating25 kV phase to phase
TestingAC Testing Voltage38 kV for 5 minutes
StandardsReference StandardTIS 2341-2555 / MEA / PEA
ConstructionConductorCompact stranded hard drawn Aluminium wire
ConstructionConductor ShieldSemi-conducting cross-linked polyethylene
ConstructionInsulationCross-linked polyethylene (Natural)
ConstructionSheathTrack resistant cross-linked polyethylene (Black)
35 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoryParameterValue
Product InfoProduct Name35 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
ApplicationApplicationFor used in primary aerial cable on pole
ClassificationNormal Operation Temperature90°C
ClassificationEmergency Overload Temperature130°C
ClassificationShort Circuit Temperature250°C
ClassificationVoltage Rating35 kV phase to phase
TestingAC Testing Voltage49 kV for 5 minutes
StandardsReference StandardTIS 2341-2555 / MEA / PEA
ConstructionConductorCompact stranded hard drawn Aluminium wire
ConstructionConductor ShieldSemi-conducting cross-linked polyethylene
ConstructionInsulationCross-linked polyethylene (Natural)
ConstructionSheathTrack resistant cross-linked polyethylene (Black)

Dimensions/Parameters

15 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)
3566.91.911.9116.00.8681820151232
5068.01.911.9117.50.6411612187291
70129.81.911.9119.00.4431445231358
951511.41.911.9121.00.3201284281451
1201512.91.911.9122.50.2531152324552
1501514.11.911.9124.00.2061070375639
1853015.81.911.9125.50.164980433763
2403018.31.911.9128.00.125874525953
25 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)
3566.93.183.1821.00.8682580149363
5068.03.183.1822.00.6412314186432
70129.83.183.1824.50.4432100229509
951511.43.183.1826.00.3201887279615
1201512.93.183.1827.00.2531712321729
1501514.13.183.1829.50.2061600371826
1853015.83.183.1831.00.1641477429959
2403018.33.183.1833.50.12513285201170
35 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)Standard packing (m)
5068.04.453.1825.50.64126061845171000/R
70129.84.453.1827.50.44323752275991000/R
951511.44.453.1829.00.32021442767111000/R
1201512.94.453.1831.00.25319523188311000/R
1501514.14.453.1832.50.20618303679331000/R
1853015.84.453.1833.50.164169442510731000/R
2403018.34.453.1836.50.125152951512931000/R
  • icon

    Production Processes Of Aerial Bundled Cable

The aerial cable manufacturing infrastructure operates a closed-loop digital automation system, integrating conductor stranding, insulation extrusion, and final sheathing into a continuous workflow. Process stability relies on embedded sensor arrays tracking extrusion parameters in real-time, eliminating manual variances. Quality validation is enforced through specific in-line hardware, including dual-axis laser diameter gauges and high-voltage spark testers, while the physical laboratory conducts destructive tensile and elongation analysis to verify compliance with international standards before shipment.

 

Production Processes Of Photovoltaic Wire

Packing For Shipment

To meet various transportation needs, there are many methods of packaging that can be used.

Packing For Shipment

Have more questions?

We’ve compiled the most common questions regarding specifications, safety standards, and applications below. If you don't see what you're looking for, or have a specific custom requirement, just contact our engineering team directly.

Q: Primary Application?

 A: MV Aerial Distribution. Designed as a safer, insulated alternative to bare conductors on pole networks.

 

Q: Why "Track-Resistant" Sheath?

 A: Physics Constraint. Pollution and moisture create leakage paths (tracking). The Black XLPE formulation physically blocks these paths to prevent flashovers.

 

Q: Sunlight/Outdoor Exposure?

A: UV Immune. Carbon-stabilized XLPE ensures long-term operational stability under direct solar radiation.

 

Q: Short-Circuit Thermal Limit?

A: 250°C. (Max tolerance for short-circuit duration without insulation breakdown).

 

Q: Coastal/Industrial Use?

A: Verified. The anti-tracking chemistry acts as a barrier against saline mist, chemical dust, and high humidity.

 

Q: Installation Method?

A: Spacer System. Requires specific insulating spacers and brackets to maintain 15kV phase-to-phase clearance.

 