  • Conductor : Compact stranded hard drawn Aluminium wire.

  • Conductor shield : Semi-conducting cross-linked polyethylene.

  • Aislamiento : Cross-linked polyethylene (Natural)

  • Funda : Track resistant cross-linked polyethylene (Black)

 Ahorre al menos 30% en promedio

SAC Aluminum Spaced Aerial Cable_1
  • icono

    Descripción del producto

    SAC Aluminum Spaced Aerial Cable : Product Description and Specifications

15kV Spaced Aerial Cable (SAC). Diseñado específicamente para Overhead Distribution Networks on pole infrastructure.

Engineering Constitution: The assembly utilizes Compact Stranded Hard-Drawn Aluminum conductors to maximize longitudinal tensile modulus, minimizing sag on long spans. The dielectric layer features a specialized Black Track-Resistant XLPE sheath. This formulation is chemically engineered to stop electrical surface tracking and prevent UV degradation, ensuring operational stability in high-exposure outdoor environments.

Cable aéreo espaciado de aluminio SAC
  • icono

    Ventajas

    SAC Aluminum Spaced Aerial Cable : Benefits and Features

  • Thermal Rating: 90°C continuous / 250°C short-circuit tolerance.

  • Insulation Physics: Black Track-Resistant XLPE. Engineered to inhibit electrical surface discharge in polluted zones.

  • Mechanical Structure: Compact Stranded Aluminum. Maximizes tensile strength and minimizes wind load.

  • Field Control: Integrated Semi-Conductive Shield ensures dielectric stability.

  • Environmental: Carbon-stabilized sheath. Impervious to UV radiation and weathering.

  • Installation: Lightweight Profile. Reduces pole static load compared to standard bundled cables.

Specification Of SAC Aluminum Spaced Aerial Cable

15 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoríaParámetroValor
Product InfoProduct Name15 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
AplicaciónAplicaciónFor used in primary aerial cable on pole
ClasificaciónNormal Operation Temperature90°C
ClasificaciónEmergency Overload Temperature130°C
ClasificaciónShort Circuit Temperature250°C
ClasificaciónClasificación de voltaje15 kV phase to phase
PruebasAC Testing Voltage27 kV for 5 minutes
EstándaresReference StandardPDITL / MEA / PEA
ConstrucciónConductorCompact stranded hard drawn Aluminium wire
ConstrucciónConductor ShieldSemi-conducting cross-linked polyethylene
ConstrucciónAislamientoCross-linked polyethylene (Natural)
ConstrucciónFundaTrack resistant cross-linked polyethylene (Black)
25 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoríaParámetroValor
Product InfoProduct Name25 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
AplicaciónAplicaciónFor used in primary aerial cable on pole
ClasificaciónNormal Operation Temperature90°C
ClasificaciónEmergency Overload Temperature130°C
ClasificaciónShort Circuit Temperature250°C
ClasificaciónClasificación de voltaje25 kV phase to phase
PruebasAC Testing Voltage38 kV for 5 minutes
EstándaresReference StandardTIS 2341-2555 / MEA / PEA
ConstrucciónConductorCompact stranded hard drawn Aluminium wire
ConstrucciónConductor ShieldSemi-conducting cross-linked polyethylene
ConstrucciónAislamientoCross-linked polyethylene (Natural)
ConstrucciónFundaTrack resistant cross-linked polyethylene (Black)
35 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
CategoríaParámetroValor
Product InfoProduct Name35 kV ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED AND SHEATHED SPACED AERIAL CABLE
AplicaciónAplicaciónFor used in primary aerial cable on pole
ClasificaciónNormal Operation Temperature90°C
ClasificaciónEmergency Overload Temperature130°C
ClasificaciónShort Circuit Temperature250°C
ClasificaciónClasificación de voltaje35 kV phase to phase
PruebasAC Testing Voltage49 kV for 5 minutes
EstándaresReference StandardTIS 2341-2555 / MEA / PEA
ConstrucciónConductorCompact stranded hard drawn Aluminium wire
ConstrucciónConductor ShieldSemi-conducting cross-linked polyethylene
ConstrucciónAislamientoCross-linked polyethylene (Natural)
ConstrucciónFundaTrack resistant cross-linked polyethylene (Black)

Dimensiones/Parámetros

15 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)
3566.91.911.9116.00.8681820151232
5068.01.911.9117.50.6411612187291
70129.81.911.9119.00.4431445231358
951511.41.911.9121.00.3201284281451
1201512.91.911.9122.50.2531152324552
1501514.11.911.9124.00.2061070375639
1853015.81.911.9125.50.164980433763
2403018.31.911.9128.00.125874525953
25 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)
3566.93.183.1821.00.8682580149363
5068.03.183.1822.00.6412314186432
70129.83.183.1824.50.4432100229509
951511.43.183.1826.00.3201887279615
1201512.93.183.1827.00.2531712321729
1501514.13.183.1829.50.2061600371826
1853015.83.183.1831.00.1641477429959
2403018.33.183.1833.50.12513285201170
35 kV SAC Aluminum Spaced Aerial Cable
Nominal cross-sectional area (mm2)Minimum number of wire (No.)Diameter of conductor (Approx.) (mm)Thickness of insulation (mm)Thickness of sheath (mm)Overall diameter (Approx.) (mm)Maximum DC. conductor resistance at 20°C (Ω/km)Minimum insulation resistance at 15.6°C (MΩ-km)Allowable ampacities in free air at 40°C ambient (A)Cable weight (Approx.) (kg/km)Standard packing (m)
5068.04.453.1825.50.64126061845171000/R
70129.84.453.1827.50.44323752275991000/R
951511.44.453.1829.00.32021442767111000/R
1201512.94.453.1831.00.25319523188311000/R
1501514.14.453.1832.50.20618303679331000/R
1853015.84.453.1833.50.164169442510731000/R
2403018.34.453.1836.50.125152951512931000/R
  • icono

    Procesos de producción de cables aéreos agrupados

La infraestructura de fabricación de cables aéreos opera un sistema de automatización digital de circuito cerrado, que integra el trenzado del conductor, la extrusión del aislamiento y el revestimiento final en un flujo de trabajo continuo. La estabilidad del proceso se basa en conjuntos de sensores integrados que rastrean los parámetros de extrusión en tiempo real, eliminando las variaciones manuales. La validación de la calidad se aplica a través de hardware en línea específico, incluidos medidores de diámetro láser de doble eje y probadores de chispas de alto voltaje, mientras que el laboratorio físico realiza análisis destructivos de tracción y alargamiento para verificar el cumplimiento de los estándares internacionales antes del envío.

 

Procesos de Producción de Alambre Fotovoltaico

Embalaje para envío

Para satisfacer diversas necesidades de transporte, existen muchos métodos de embalaje que se pueden utilizar.

Embalaje para envío

¿Tienes más preguntas?

A continuación, recopilamos las preguntas más comunes sobre especificaciones, estándares de seguridad y aplicaciones. Si no ve lo que está buscando o tiene un requisito personalizado específico, simplemente comuníquese directamente con nuestro equipo de ingeniería.

P: ¿Aplicación primaria?

 A: MV Aerial Distribution. Designed as a safer, insulated alternative to bare conductors on pole networks.

 

Q: Why "Track-Resistant" Sheath?

 A: Physics Constraint. Pollution and moisture create leakage paths (tracking). The Black XLPE formulation physically blocks these paths to prevent flashovers.

 

Q: Sunlight/Outdoor Exposure?

A: UV Immune. Carbon-stabilized XLPE ensures long-term operational stability under direct solar radiation.

 

Q: Short-Circuit Thermal Limit?

A: 250°C. (Max tolerance for short-circuit duration without insulation breakdown).

 

Q: Coastal/Industrial Use?

A: Verificado. The anti-tracking chemistry acts as a barrier against saline mist, chemical dust, and high humidity.

 

Q: Installation Method?

A: Spacer System. Requires specific insulating spacers and brackets to maintain 15kV phase-to-phase clearance.

 

Q: How to Request Quotation?

A: Acțiune: Haga clic en el “Contáctenos” botón o ver el Perfil del vendedor directly for technical pricing.

Desplácese hasta Arriba
Póngase en contacto con la empresa JOCA

Complete el siguiente formulario para comunicarse con nosotros. Nuestro objetivo es comunicarnos con usted en un plazo de 12 horas. ¡Te deseo lo mejor!

Demostración del formulario de contacto

JOCA