Fraude Blocker

JOCA

N2XSEBY/NA2XSEBY

3.6KV-35KV XLPE Insulation Steel Tape Armoured and PVC Jacket power cable

  • Conductor : Copper or Aluminum(Class 2 according to IEC 60502-2).
  • Isolatie : XLPE
  • Metallic Screen :  Copper Tape
  • Separation Layer :  Non-hygroscopic Tape. 
  • Inner Sheath : PVC
  • Armour : Steel Tape Armor (STA).
  • Buitenschede : PVC 
  • Color : Usually Red or Black.
  •  

 Bespaar gemiddeld minimaal 30%

N2XSEBY-NA2XSEBY
  • icon

    Productbeschrijving

    N2XSEBY/NA2XSEBY : Product Description and Specifications

The N2XSEBY (Copper) and NA2XSEBY (Aluminum) series are engineered for Medium Voltage networks ranging from 3.6kV to 35kV. Unlike standard cables, this specification incorporates Dubbel stalen tapepantser (DSTA). This metallic reinforcement creates a rigid barrier against crushing loads, allowing for direct burial in cable trenches where mechanical pressure is a concern. The core is insulated with high-grade XLPE and protected by a heavy-duty PVC sheath, ensuring full compliance with IEC 60502-2 standards for grid stability.

N2XSEBY-NA2XSEBY_1
  • icon

    Voordelen

    N2XSEBY/NA2XSEBY : Benefits and Features

  • Steel Tape Armor (DSTA): The cable utilizes double layers of galvanized steel tape. This structure is specifically engineered to resist radial crushing loads, making it the standard choice for direct burial in soil.

  • XLPE Insulation: Beoordeeld voor 90°C continuous operation. This material provides significantly higher dielectric strength and thermal headroom than legacy PVC insulation.

  • Copper Tape Screen: A metallic tape layer applied over the insulation to uniformly control electric field stress and provide a designated path for fault currents.

  • Conductor Flexibility: Specification allows for Class 2 Stranded Copper (for ampacity) or Aluminum (for weight reduction), depending on load requirements.

  • Protective Sheathing: The ST2 type PVC jacket creates a hermetic seal against moisture ingress and chemical corrosion in underground environments.

Afmetingen/parameters

3.6/6 (7.2) KV XLPE/PVC 3 cores (steel tape armored) YJV22, YJLV22
Cross sectional area (mm2)Conductor StructureConductor Outer diameter (mm)Insulation thickness (mm)Copper tape screen (approximate) (mm)PVC bedding thickness (mm)Armored tape thickness (approx.) (mm)Sheath thickness (mm)Outer diameter (approximate) (mm)Copper core cable weight (kg/km)Aluminum core cable weight (kg/km)
25Compact round6.02.50.11.20.52.239.324742002
35Compact round7.22.50.11.30.52.342.329472286
50Compact round8.42.50.11.30.52.445.135372593
70Compact round10.02.50.11.40.52.548.943513030
95Compact round11.72.50.11.40.52.652.852973504
120Compact round13.12.50.11.50.52.856.462774012
150Compact round14.62.50.11.60.52.960.073734541
185Compact round16.32.50.11.60.53.063.986655172
240Compact round18.52.60.11.70.53.269.7106186087
300Compact round20.72.80.11.80.53.476.3128367173
400Compact round23.83.00.12.00.83.786.1171959644
500Compact round26.63.20.12.10.83.994.82088711448
6/6(7.2),6/10(12)KV XLPE/PVC 3 cores(steel tape armored) YJV22,YJLV22
Cross sectional area (mm2)StructureOuter diameter (mm)Insulation thickness (mm)Copper tape screen (approximate) (mm)PVC bedding thickness (mm)Armored wire outer diameter (mm)Sheath thickness (mm)Outer diameter (approximate) (mm)Copper core cable weight (kg/km)Aluminum core cable weight (kg/km)
25Compact round6.03.40.11.32.52.548.041753703
35Compact round7.23.40.11.32.52.650.847334072
50Compact round8.43.40.11.42.52.753.854914547
70Compact round10.03.40.11.52.52.857.664465124
95Compact round11.73.40.11.52.52.961.575305737
120Compact round13.13.40.11.62.53.064.986286363
150Compact round14.63.40.11.62.53.168.397946963
185Compact round16.33.40.11.72.53.372.6113267834
240Compact round18.53.40.11.83.153.579.2142689737
300Compact round20.73.40.11.93.153.684.81664110978
400Compact round23.83.40.12.03.153.992.32036212811
500Compact round26.63.40.12.13.154.199.32420314764
8.7/10(12),8.7/15(17.5)KV XLPE/PVC 3 cores (steel tape armored) YJV22,YJLV22
Conductor Cross sectional area (mm2)Conductor StructureConductor Outer diameter (mm)Insulation thickness (mm)Copper tape screen (approximate) (mm)PVC bedding thickness (mm)Armored tape outer diameter (mm)Sheath thickness (mm)Outer diameter (approximate) (mm)Copper core cable weight (kg/km)Aluminum core cable weight (kg/km)
25Compact round6.04.50.11.40.52.548.932272755
35Compact round7.24.50.11.40.52.651.737113050
50Compact round8.44.50.11.50.52.754.743723428
70Compact round10.04.50.11.50.52.858.452083886
95Compact round11.74.50.11.60.53.062.662714477
120Compact round13.14.50.11.70.53.166.072544989
150Compact round14.64.50.11.70.53.269.584205588
185Compact round16.34.50.11.80.53.373.597316239
240Compact round18.54.50.11.90.53.578.9117157184
300Compact round20.74.50.12.00.83.785.8147749111
400Compact round23.84.50.12.10.83.993.11835010798
500Compact round26.64.50.12.20.84.1101.02199012551
12/20(24)XLPE/PVC 3 cores(steel tape armored)YJV22,YJLV22
Conductor Cross sectional area (mm2)Conductor StructureConductor Outer diameter (mm)Insulation thickness (mm)Copper tape screen (approximate) (mm)PVC bedding thickness (mm)Armored tape outer diameter (mm)Sheath thickness (mm)Outer diameter (approximate) (mm)Copper core cable weight (kg/km)Aluminum core cable weight (kg/km)
35Compact round7.25.50.11.50.52.856.641823521
50Compact round8.45.50.11.60.52.959.648663922
70Compact round10.05.50.11.60.53.063.357384417
95Compact round11.75.50.11.70.53.167.367834990
120Compact round13.15.50.11.80.53.270.778475582
150Compact round14.65.50.11.80.53.374.289726141
185Compact round16.35.50.11.90.53.578.4103526859
240Compact round18.55.50.12.00.83.785.0132298698
300Compact round20.75.50.12.10.83.890.5155239860
400Compact round23.85.50.12.20.84.198.01911011559
500Compact round26.65.50.12.30.84.3105.92290913470
18/30(36)XLPE/PVC 3 cores(steel tape armored)YJV22,YJLV22
Conductor Cross sectional area (mm2)Conductor StructureConductor Outer diameter (mm)Insulation thickness (mm)Copper tape screen (approximate) (mm)PVC bedding thickness (mm)Armored tape outer diameter (mm)Sheath thickness (mm)Outer diameter (approximate) (mm)Copper core cable weight (kg/km)Aluminum core cable weight (kg/km)
50Compact round8.48.00.11.80.53.371.662795335
70Compact round10.08.00.11.80.53.475.271895868
95Compact round11.78.00.11.90.53.579.383056511
120Compact round13.18.00.12.00.83.784.1102577992
150Compact round14.68.00.12.00.83.887.5114358603
185Compact round16.38.00.12.10.83.991.6129339441
240Compact round18.58.00.12.20.84.196.91504310512
300Compact round20.78.00.12.30.84.2102.51741211749
400Compact round23.88.00.12.40.84.5110.02122913678
500Compact round26.68.00.12.50.84.7117.92514515706
21/35 (40.5) XLPE/PVC 3 cores (steel tape armored) YJV22,YJLV22
Conductor Cross sectional area (mm2)Conductor StructureConductor Outer diameter (mm)Insulation thickness (mm)Copper tape screen (approximate) (mm)PVC bedding thickness (mm)Armored tape thickness (mm)Sheath thickness (mm)Cable Outer diameter (approximate) (mm)Copper core cable weight (kg/km)Aluminum core cable weight (kg/km)
50Compact round8.49.30.11.90.53.578.270766132
70Compact round10.09.30.12.00.83.683.388647543
95Compact round11.79.30.12.00.83.887.3100948301
120Compact round13.19.30.12.10.83.990.7111908925
150Compact round14.69.30.12.20.84.094.4125279695
185Compact round16.39.30.12.20.84.198.21400310511
240Compact round18.59.30.12.30.84.3103.61616011629
300Compact round20.79.30.12.40.84.4109.11869113028
400Compact round23.89.30.12.50.84.7116.62244614895
26/35 (40.5) XLPE/PVC 3 cores (steel tape armored) YJV22, YJLV22
Cross sectional area (mm2)StructureConductor Outer diameter (mm)Insulation thickness (mm)Copper tape screen (approximate) (mm)PVC bedding thickness (mm)Armored tape outer diameter (mm)Sheath thickness (mm)Outer diameter (approximate) (mm)Copper core cable weight (kg/km)Aluminum core cable weight (kg/km)
50Compact round8.410.50.11.90.83.785.687937849
70Compact round10.010.50.12.00.83.889.598178495
95Compact round11.710.50.12.00.83.993.3110369243
120Compact round13.110.50.12.10.84.196.9122419976
150Compact round14.610.50.12.20.84.2100.61355810726
185Compact round16.310.50.12.20.84.3104.41508511592
240Compact round18.510.50.12.30.84.5109.81738112850
300Compact round20.710.50.12.40.84.6115.31983014167
400Compact round23.810.50.12.50.84.9122.82368916138
500Compact round26.610.50.12.90.85.2131.62658417145
  • icon

    Productieprocessen van stroomkabel

Om superieure kwaliteit te verzekeren, JOCA opereert volledig gedigitaliseerde en geautomatiseerde productielijnen voor stroomkabels. Specifiek, deze uitgebreide workflow covers geleiderstreng, isolatie-extrusie, metaalafscherming en eindafdekking. Bovendien, intelligente systemen actief monitoren elke fase om stabiele prestaties en consistente productkwaliteit te garanderen. Daarnaast, de fabriek gebruikt geavanceerde testfaciliteiten, zoals gedeeltelijke ontladingstests, trekproeven en vonktesten. Bijgevolg, deze rigoureuze maatregelen garantie dat elke geleverde kabel strikt voldoet aan internationale normen.

Productieprocessen van fotovoltaïsche draad

Verpakking voor verzending

Om aan verschillende transportbehoeften te voldoen, zijn er veel verpakkingsmethoden die kunnen worden gebruikt.

power kabel verpakking

Heb je nog meer vragen?

We hebben hieronder de meest voorkomende vragen over specificaties, veiligheidsnormen en toepassingen samengesteld. Als u niet ziet wat u zoekt, of als u een specifieke aangepaste vereiste heeft, neem dan rechtstreeks contact op met ons technische team.

Q: N2XSEBY vs. NA2XSEBY: Wat is het technische verschil?

A: Het onderscheid ligt strikt in het geleidermetaal. N2XSEBY maakt gebruik van koperen geleiders. The “A” in NA2XSEBY geeft aluminium geleiders aan, die een lichter, kostengeoptimaliseerd alternatief bieden voor vergelijkbare spanningsgraden.

 

 

Q: Voltage Application Range?

A: These cables are engineered for the full Medium Voltage spectrum, typically covering 3.6/6kV up to 26/35kV.

 

Q: Standard Sheath Colors?

A: Standard production runs are typically Red of Black. However, UV-stabilized Black is recommended for outdoor exposure.

 

Q: Manufacturing Standards?

A: The construction and testing strictly adhere to IEC 60502-2.

 

Q: Can this be installed outdoors?

 A: Ja. The PVC outer jacket provides necessary weather and UV resistance. For extreme sunlight exposure, we specifically recommend the black sheath option.

 

Q: Isolatiemateriaal?

 A: XLPE (Cross-Linked Polyethylene). We use this instead of PVC to allow for a higher continuous operating temperature of 90°C.

Q: Does it include a metallic screen?

A: Correct. It features a Copper Tape screen. This layer is critical for controlling electric field stress and providing a path for fault currents.

 

Q: Composition of the inner and outer sheaths?

A: Both the inner bedding and the final outer jacket utilize Extruded PVC (Type ST2) for mechanical durability.