UL1015
105°C PVC Hook-Up Wire for Internal Wiring of Electrical & Electronic Equipment
Internal wiring of household appliances and electronic equipment
Power supply wiring inside electrical cabinets and devices
General industrial machinery requiring durable 600V hook-up wire
Control panels, lighting equipment, office equipment
Suitable for environments exposed to oil, bending or abrasion
- Snelle monsterverwerking met oplossingen op maat
- Hoogwaardige materialen
- Betaalbare Prijs Opties
- Global Delivery
- Zorg er voor een betere gegevensbescherming voor dat alle uploads veilig zijn
Bespaar gemiddeld minimaal 30%
-
Productbeschrijving
UL1015 : Product Description and Specifications
Think of UL1015 as the heavy-duty upgrade to standard electronic wire. While common wires stop at 300V, UL1015 features a thicker PVC insulation wall (approx. 0.8mm), boosting its rating to 600V AC. This extra thickness doesn’t just block electricity; it provides physical armor against oil splashes, mechanical abrasion, and vibration inside machinery.
Designed for the “hot zones” of electrical cabinets and power supplies, it is rated to withstand 105°C (far exceeding the standard 80°C limit). Whether you are wiring rectifiers, transformers, or industrial panels, this wire meets strict UL758, UL1581, and CSA C22.2 safety protocols for high-voltage internal connections
-
Voordelen
UL1015 : Benefits and Features
Rated 600V for a wide range of industrial and commercial equipment
105°C PVC insulation with strong thermal and mechanical stability
Excellent oil resistance, wear resistance and flame-retardant performance
Smooth surface, easy stripping and processing for automated equipment
Available with tin-coated or bare copper conductors
Complies with UL VW-1 & CSA FT1 flame tests
RoHS & REACH compliant
Specification Of UL1015
| Categorie | Specification Detail |
|---|---|
| ApplicationScope | Suitable for internal wiring of general electronic and electrical equipment. When exposed to an oil environment, it must not exceed 60°C or 80°C. |
| ApplicationScope | Oil resistance for this wire type is optional. |
| ApplicationScope | Application Standards: UL758, UL1581, and CSA C22.2 NO.210.2 |
| CableStructure | Conductor: Uses 30-4/0 AWG solid or stranded bare copper or tinned copper wire |
| CableStructure | Insulation: Polyvinyl Chloride (PVC) Insulation |
| CableStructure | Core Color: Any color |
| Features | Uses standard thickness, easy to strip, easy to cut. |
| Features | Features resistance to acids and alkalis, oil resistance, moisture resistance, mold resistance, and environmental friendliness. |
| TechnicalParameters | Rated Voltage: 600V |
| TechnicalParameters | Test Voltage: 2000V, 2500V |
| TechnicalParameters | Rated Temperature: 105°C (Optional 80°C and 90°C) |
| TechnicalParameters | Flame Test: Passes UL VW-1, CSA FT1, and JQAF-Mark flame retardant tests |
Afmetingen/parameters
| Model | Specificatie | Approximate Outer Diameter (mm) | Approximate Cable Weight (kg/km) |
|---|---|---|---|
| UL1015 | 3/0AWG | 17.37 | 944.89 |
| UL1015 | 2/0AWG | 16.02 | 767.71 |
| UL1015 | 1/0AWG | 14.55 | 622.73 |
| UL1015 | 1AWG | 13.57 | 511.73 |
| UL1015 | 2AWG | 11.42 | 387.16 |
| UL1015 | 3AWG | 10.45 | 316.19 |
| UL1015 | 4AWG | 9.65 | 258.31 |
| UL1015 | 5AWG | 8.92 | 212.75 |
| UL1015 | 6AWG | 8.27 | 175.67 |
| UL1015 | 7AWG | 6.89 | 129.48 |
| UL1015 | 8AWG | 6.43 | 107.83 |
| UL1015 | 9AWG | 5.28 | 79.03 |
| UL1015 | 10AWG | 4.77 | 64.16 |
| UL1015 | 11AWG | 4.20 | 50.57 |
| UL1015 | 12AWG | 3.90 | 41.44 |
| UL1015 | 13AWG | 3.66 | 34.75 |
| UL1015 | 14AWG | 3.43 | 29.00 |
| UL1015 | 15AWG | 3.22 | 24.21 |
| UL1015 | 16AWG | 3.03 | 20.41 |
| UL1015 | 17AWG | 2.86 | 17.03 |
| UL1015 | 18AWG | 2.72 | 14.70 |
| UL1015 | 19AWG | 2.60 | 12.79 |
| UL1015 | 20AWG | 2.48 | 11.07 |
| UL1015 | 21AWG | 2.36 | 9.54 |
| UL1015 | 22AWG | 2.30 | 8.75 |
| UL1015 | 23AWG | 2.20 | 7.67 |
| UL1015 | 24AWG | 2.15 | 7.10 |
| UL1015 | 25AWG | 2.05 | 6.22 |
| UL1015 | 26AWG | 2.02 | 5.91 |
| UL1015 | 28AWG | 1.90 | 4.90 |
| UL1015 | 30AWG | 1.84 | 4.46 |
Certifications Of UL1015
-
Productieprocessen van UL-kabel
JOCA produceert UL-draden met behulp van een volledig geautomatiseerde workflow De cyclus synchroniseert koper trekken en stranden met precieze PVC of XLPE extrusie. In plaats van te wachten op postproductiecontroles, gebruiken wij continue inline monitoring1. Laserdiametermeters en vonktesters om defecten onmiddellijk op te sporen. Voor varianten met meerdere kernen verwerkt de lijn bekabeling, afscherming en mantel volgens exacte specificaties. Vóór verzending wordt elke batch geconfronteerd met definitieve elektrische en mechanische inspecties om de volledige naleving ervan te verifiëren UL-normen.
Verpakking voor verzending
Om aan verschillende transportbehoeften te voldoen, zijn er veel verpakkingsmethoden die kunnen worden gebruikt.
Heb je nog meer vragen?
Q: UL1007 vs. UL1015: Which one do I need?
A: Check your Voltage Requirement.
UL1007: Rated 300V. Thinner wall. Good for low-voltage signals.
UL1015: Rated 600V. Thicker wall (approx 0.8mm). Required for Power Supply inputs and high-voltage internal wiring.
Q: Is it safe for power supply internals?
A: Ja. This is its main job. Because of the 600V rating en VW-1 Flame Resistance, it is standard for the “Primary Side” (high voltage side) of power units and rectifiers.
Q: Can it handle oil?
A: Splash resistant? Yes. It handles machine oil splatters in workshops. Submersion? No. If the wire sits in a tank of hot oil, switch to Teflon (FEP) or XLPE wire.
Q: Will it jam my stripping machine?
A: No. The PVC jacket is engineered to be non-sticky. It cuts cleanly and slides off the conductor, ensuring high-speed automated processing without gumming up the blades.
Q: Bare Copper or Tinned Copper?
A: We strongly recommend Ingeblikt koper. It costs slightly more but resists oxidation (turning black) and is much easier to solder than bare copper.
Q: What are the temperature limits?
A: It is rated for 105°C (Hot). This is significantly higher than the standard 80°C of UL1007, making it safer for crowded, hot cabinets.
Q: Is it actually UL listed?
A: Yes. It carries dual certification: UL AWM Style 1015 and CSA TEW. You will find the file numbers printed directly on the wire insulation for inspection.
Q: Need custom colors or cut lengths?
A: Don’t struggle with standard spools if they don’t fit. Hit the “Contact Us” button. Tell us your required length and color (Stripes? Solid?), and we’ll get you a quote.