Blocant de fraudă

JOCA

N2XSB(AL)Y/NA2XSB(AL)Y

3,6KV-35KV XLPE Bandă de aluminiu izolație Cablu de alimentare cu jachetă blindată și PVC

  • Dirijor: Cupru sau aluminiu (Clasa 2 conform IEC 60502-2).
  • Izolație : XLPE
  • Ecran metalic : Bandă de cupru
  • Stratul de separare : Bandă non-higroscopică. 
  • Teaca interioară : PVC
  • Armură : Aluminum Tape Armor (ATA).
  • Teaca exterioară : PVC 
  • Culoare : De obicei roșu sau negru.

 Economisiți cel puțin 30% în medie

N2XSB(AL)Y-NA2XSB(AL)Y_1
  • pictogramă

    Descrierea produsului

    N2XSB(AL)Y/NA2XSB(AL)Y : Product Description and Specifications

The N2XSB(AL)Y series is a dedicated Medium Voltage (3.6kV–35kV) cable for power transmission. It combines a high-conductivity Copper conductor with XLPE insulation. Crucially, the mechanical protection uses Aluminum Tape Armor (ATA) rather than steel. Since Aluminum is non-magnetic, this design eliminates the risk of eddy current overheating in single-core circuits while still providing the crush resistance required for direct underground burial. The assembly is finished with a weather-resistant PVC sheath, suitable for industrial grids and renewable energy infrastructure.

N2XSB(AL)Y-NA2XSB(AL)Y
  • pictogramă

    Avantaje

    N2XSB(AL)Y/NA2XSB(AL)Y : Benefits and Features

  • 90°C Rated: XLPE handles the heat. It runs hotter and harder than standard PVC cables.

  • Aluminum Tape Armor: A physical shield. It stops crushing rocks and keeps hungry rodents from chewing through.

  • Weatherproof: Sun, rain, or mud? No problem. The jacket shrugs it off.

  • 25-Year Life: TUV certified. Install it and forget about it for a quarter-century.

  • Install Anywhere: Direct burial, trenches, or even floating solar rigs. It handles it all.

Dimensiuni/Parametri

3.6/6 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
250.7270.9270.4540.5001661531701563.581.14
350.5240.6680.4310.4772011832061875.011.14
500.3870.4940.4130.4592402162462217.151.14
700.2680.3420.3890.43529926430727010.011.14
950.1930.2470.3730.41936331537232213.591.14
1200.1530.1960.3580.40441835842836517.161.14
1500.1240.1590.3470.39347640148741021.451.14
1850.09910.1280.3380.38554545255746126.461.14
2400.07540.0980.3260.37264252365753234.321.14
3000.06010.0790.3160.36273458875059842.901.14
4000.04700.0630.3050.35185266686967757.201.14
5000.03660.0510.2970.34398075099776071.501.14
6300.02830.0410.2890.3351120840113784890.091.14
6/10 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
250.7270.9270.4370.4841641531681573.581.14
350.5240.6680.4150.4611991832041885.011.14
500.3870.4940.3980.4442372162432217.151.14
700.2680.3420.3740.42129626430427010.011.14
950.1930.2470.3580.40436031636932313.591.14
1200.1530.1960.3460.39241635842636617.161.14
1500.1240.1590.3340.38047340248441021.451.14
1850.09910.1280.3250.37154145355446226.461.14
2400.07540.0980.3160.36263952365453334.321.14
3000.06010.0790.3090.35673358874859842.901.14
4000.04700.0630.3000.34685166786867757.201.14
5000.03660.0510.2940.34197975199776071.501.14
6300.02830.0410.2860.3321120840113684890.091.14
8.7/15 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
250.7270.9270.4730.5191681531721563.581.14
350.5240.6680.4480.4952031832081875.011.14
500.3870.4940.4300.4762422162482207.151.14
700.2680.3420.4050.45130226330926910.011.14
950.1930.2470.3870.43336631537432113.591.14
1200.1530.1960.3760.42242235743136417.161.14
1500.1240.1590.3630.40947940149040921.451.14
1850.09910.1280.3520.39954845256046026.461.14
2400.07540.0980.3380.38564552265953234.321.14
3000.06010.0790.3270.37473858875359842.901.14
4000.04700.0630.3170.36385566787167657.201.14
5000.03660.0500.3070.353984752100076171.501.14
6300.02830.0410.2970.3441125842114185090.091.14
12/20 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
350.5240.6680.4650.5112051832101875.011.14
500.3870.4940.4450.4912442152492207.151.14
700.2680.3420.4200.46630426331126910.011.14
950.1930.2470.4040.45036831437632013.591.14
1200.1530.1960.3890.43542435743336417.161.14
1500.1240.1590.3760.42248240049240821.451.14
1850.09910.1270.3640.41055045156246026.461.14
2400.07540.0980.3490.39564852266153234.321.14
3000.06010.0790.3380.38474058875559742.901.14
4000.04700.0630.3270.37385866787367657.201.14
5000.03660.0500.3160.362986752100276171.501.14
6300.02830.0410.3060.3521128843114385090.091.14
18/30 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
500.3870.4940.4810.5282482142532197.151.14
700.2680.3420.4530.50030826231426810.011.14
950.1930.2470.4340.48037231338031913.591.14
1200.1530.1960.4170.46342835643736317.161.14
1500.1240.1590.4030.44948639949640721.451.14
1850.09910.1270.3910.43855445056545926.461.14
2400.07540.0980.3760.42265252166453034.321.14
3000.06010.0780.3640.41074458775759642.901.14
4000.04700.0620.3490.39586166687667657.201.14
5000.03660.0500.3370.383990753100576171.501.14
6300.02830.0400.3270.3731132845114585290.091.14
  • pictogramă

    Procese de producție ale cablului de alimentare

Pentru a asigura o calitate superioară, JOCA operează linii de producție complet digitalizate și automatizate pentru cabluri alimentare. Specific, acest flux de lucru cuprinzător acoperă toroane conductoare, extrudare izolație, ecranare metalică și înveliș final. Mai mult, sisteme inteligente monitorizați activ fiecare etapă pentru a asigura o performanță stabilă și o calitate constantă a produsului. În plus, fabrica utilizează facilități avansate de testare, cum ar fi testarea cu descărcare parțială, testarea la tracțiune și testarea scânteilor. În consecinţă, aceste măsuri riguroase garanţie că fiecare cablu livrat respectă cu strictețe standardele internaționale.

Procese de producție a sârmei fotovoltaice

Ambalare pentru expediere

Pentru a satisface diverse nevoi de transport, există multe metode de ambalare care pot fi utilizate.

ambalare cablu de alimentare

Ai mai multe întrebări?

Începeți cu ușurință prin a găsi răspunsurile la întrebările frecvente despre compania și serviciile noastre.

Q: Voltage range?

 A: It handles the full Medium Voltage spread: 3.6kV all the way to 35kV.

 

Q: Insulation material?

 A: XLPE. It beats PVC hands down because it can run hotter (90°C) without degrading.

Q: Why use Aluminum Tape Armor?

A: Protection without the weight. It stops rats from chewing the core and protects against light impact. Plus, since it’s aluminum, it won’t overheat magnetically like steel does on single-core cables.

 

Q: Can I bury it?

A: Go for it. That’s what the armor is for. Dig the trench, drop it in, and cover it up.

 

Q: Max temp?

A: It runs happily at 90°C continuous. No sweat.

 

Q: Where can I install it?

A: Pretty much anywhere. Solar farms, rooftops, or even floating PV rigs. It’s built for the outdoors.

 

Q: Conductor type?

A: High-grade Cupru eșuat. We don’t skimp on the metal.

 

Q: How long will it last?

 A: It’s certified for 25 years. Install it properly, and you won’t have to touch it for decades.

Derulați în sus
Luați legătura cu compania JOCA

Vă rugăm să completați formularul de mai jos pentru a ne contacta. Ne propunem să vă răspundem în termen de 12 ore. Vă dorim tot ce este mai bun!

Demo formular de contact

JOCA