Fraud Blocker

JOCA

N2XSB(AL)Y/NA2XSB(AL)Y

3.6KV-35KV XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable

  • Conductor : Copper or Aluminum(Class 2 according to IEC 60502-2).
  • Insulation : XLPE
  • Metallic Screen :  Copper Tape
  • Separation Layer :  Non-hygroscopic Tape. 
  • Inner Sheath : PVC
  • Armour : Aluminum Tape Armor (ATA).
  • Outer Sheath : PVC 
  • Color : Usually Red or Black.

 Save at least 30% on average

N2XSB(AL)Y-NA2XSB(AL)Y_1
  • icon

    Product Description

    N2XSB(AL)Y/NA2XSB(AL)Y : Product Description and Specifications

The N2XSB(AL)Y series is a dedicated Medium Voltage (3.6kV–35kV) cable for power transmission. It combines a high-conductivity Copper conductor with XLPE insulation. Crucially, the mechanical protection uses Aluminum Tape Armor (ATA) rather than steel. Since Aluminum is non-magnetic, this design eliminates the risk of eddy current overheating in single-core circuits while still providing the crush resistance required for direct underground burial. The assembly is finished with a weather-resistant PVC sheath, suitable for industrial grids and renewable energy infrastructure.

N2XSB(AL)Y-NA2XSB(AL)Y
  • icon

    Advantages

    N2XSB(AL)Y/NA2XSB(AL)Y : Benefits and Features

  • 90°C Rated: XLPE handles the heat. It runs hotter and harder than standard PVC cables.

  • Aluminum Tape Armor: A physical shield. It stops crushing rocks and keeps hungry rodents from chewing through.

  • Weatherproof: Sun, rain, or mud? No problem. The jacket shrugs it off.

  • 25-Year Life: TUV certified. Install it and forget about it for a quarter-century.

  • Install Anywhere: Direct burial, trenches, or even floating solar rigs. It handles it all.

Dimensions/Parameters

3.6/6 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
250.7270.9270.4540.5001661531701563.581.14
350.5240.6680.4310.4772011832061875.011.14
500.3870.4940.4130.4592402162462217.151.14
700.2680.3420.3890.43529926430727010.011.14
950.1930.2470.3730.41936331537232213.591.14
1200.1530.1960.3580.40441835842836517.161.14
1500.1240.1590.3470.39347640148741021.451.14
1850.09910.1280.3380.38554545255746126.461.14
2400.07540.0980.3260.37264252365753234.321.14
3000.06010.0790.3160.36273458875059842.901.14
4000.04700.0630.3050.35185266686967757.201.14
5000.03660.0510.2970.34398075099776071.501.14
6300.02830.0410.2890.3351120840113784890.091.14
6/10 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
250.7270.9270.4370.4841641531681573.581.14
350.5240.6680.4150.4611991832041885.011.14
500.3870.4940.3980.4442372162432217.151.14
700.2680.3420.3740.42129626430427010.011.14
950.1930.2470.3580.40436031636932313.591.14
1200.1530.1960.3460.39241635842636617.161.14
1500.1240.1590.3340.38047340248441021.451.14
1850.09910.1280.3250.37154145355446226.461.14
2400.07540.0980.3160.36263952365453334.321.14
3000.06010.0790.3090.35673358874859842.901.14
4000.04700.0630.3000.34685166786867757.201.14
5000.03660.0510.2940.34197975199776071.501.14
6300.02830.0410.2860.3321120840113684890.091.14
8.7/15 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
250.7270.9270.4730.5191681531721563.581.14
350.5240.6680.4480.4952031832081875.011.14
500.3870.4940.4300.4762422162482207.151.14
700.2680.3420.4050.45130226330926910.011.14
950.1930.2470.3870.43336631537432113.591.14
1200.1530.1960.3760.42242235743136417.161.14
1500.1240.1590.3630.40947940149040921.451.14
1850.09910.1280.3520.39954845256046026.461.14
2400.07540.0980.3380.38564552265953234.321.14
3000.06010.0790.3270.37473858875359842.901.14
4000.04700.0630.3170.36385566787167657.201.14
5000.03660.0500.3070.353984752100076171.501.14
6300.02830.0410.2970.3441125842114185090.091.14
12/20 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
350.5240.6680.4650.5112051832101875.011.14
500.3870.4940.4450.4912442152492207.151.14
700.2680.3420.4200.46630426331126910.011.14
950.1930.2470.4040.45036831437632013.591.14
1200.1530.1960.3890.43542435743336417.161.14
1500.1240.1590.3760.42248240049240821.451.14
1850.09910.1270.3640.41055045156246026.461.14
2400.07540.0980.3490.39564852266153234.321.14
3000.06010.0790.3380.38474058875559742.901.14
4000.04700.0630.3270.37385866787367657.201.14
5000.03660.0500.3160.362986752100276171.501.14
6300.02830.0410.3060.3521128843114385090.091.14
18/30 kv XLPE Insulation Aluminum Tape Armoured and PVC Jacket power cable
Nom. Cross Sect. (mm²)DC Resistance at 20°C Max (Ω/km)AC Resistance at 90°C Max (Ω/km)Inductance Trefoil formation (mH/km)Inductance Flat formation (mH/km)Current Capacity Trefoil - in air (A)Current Capacity Trefoil - in ground (A)Current Capacity Flat - in air (A)Current Capacity Flat - in ground (A)Short circuit current at 1 sec - Conductor Max (kA)Short circuit current at 1 sec - Screen Max (kA)
500.3870.4940.4810.5282482142532197.151.14
700.2680.3420.4530.50030826231426810.011.14
950.1930.2470.4340.48037231338031913.591.14
1200.1530.1960.4170.46342835643736317.161.14
1500.1240.1590.4030.44948639949640721.451.14
1850.09910.1270.3910.43855445056545926.461.14
2400.07540.0980.3760.42265252166453034.321.14
3000.06010.0780.3640.41074458775759642.901.14
4000.04700.0620.3490.39586166687667657.201.14
5000.03660.0500.3370.383990753100576171.501.14
6300.02830.0400.3270.3731132845114585290.091.14
  • icon

    Production Processes Of Power cable

To ensure superior quality, JOCA operates fully digitalized and automated production lines for power cables. Specifically, this comprehensive workflow covers conductor stranding, insulation extrusion, metallic screening, and final sheathing. Moreover, intelligent systems actively monitor each stage to ensure stable performance and consistent product quality. In addition, the factory utilizes advanced testing facilities, such as partial discharge testing, tensile testing, and spark testing. Consequently, these rigorous measures guarantee that every delivered cable strictly meets international standards.

Production Processes Of Photovoltaic Wire

Packing For Shipment

To meet various transportation needs, there are many methods of packaging that can be used.

power cable packing

Have more questions?

Easily get started by finding the answers to commonly asked questions about our company and services.

Q: Voltage range?

 A: It handles the full Medium Voltage spread: 3.6kV all the way to 35kV.

 

Q: Insulation material?

 A: XLPE. It beats PVC hands down because it can run hotter (90°C) without degrading.

Q: Why use Aluminum Tape Armor?

A: Protection without the weight. It stops rats from chewing the core and protects against light impact. Plus, since it’s aluminum, it won’t overheat magnetically like steel does on single-core cables.

 

Q: Can I bury it?

A: Go for it. That’s what the armor is for. Dig the trench, drop it in, and cover it up.

 

Q: Max temp?

A: It runs happily at 90°C continuous. No sweat.

 

Q: Where can I install it?

A: Pretty much anywhere. Solar farms, rooftops, or even floating PV rigs. It’s built for the outdoors.

 

Q: Conductor type?

A: High-grade Stranded Copper. We don’t skimp on the metal.

 

Q: How long will it last?

 A: It’s certified for 25 years. Install it properly, and you won’t have to touch it for decades.

Scroll to Top
Get in touch with JOCA company

Kindly complete the form below to reach out to us. We aim to get back to you within 12 hours. Wishing you the very best!

Contact Form Demo

JOCA