N2XSY / NA2XSY
Isolamento XLPE Único de 3.6 KV-35 KV e cabo de alimentação da jaqueta de PVC
- Condutor:Class 2 Stranded copper/Aluminum conductor
- Conductor Screen : Semi-conductive material (Bonded Type)
- Insulation : XLPE(cross-linked polyethylene)
- Insulation Screen : Semi-conductive material (Strippable Type)
- Screen : Copper wires with Open Helix Copper Tape Screen
- Outer sheath : PVC (Polyinyl Chloride), black & red
- Processamento Rápido de Amostras com Soluções Personalizadas
- Materiais de alta qualidade
- Opções de preço acessíveis
- Entrega Global
- Para uma melhor proteção de dados, certifique-se de que todos os uploads sejam seguros
Economize pelo menos 30% em média
-
Descrição do produto
N2XSY / NA2XSY Power Cable : Product Description and Specifications
The N2XSY (Copper) and NA2XSY (Aluminum) series? They’re your standard workhorses for single-core Medium Voltage. We run them from 6kV up to 35kV.
Why use them? Well, we use XLPE insulation, not PE. Result? You get a 90°C rating and solid dielectric strength. And because they’re single-core, you don’t have to wrestle with them like those heavy three-core cables. They fit right into tight ducts or switchgear rooms. Basically, if you need ease of termination, this is the one.
-
Vantagens
N2XSY / NA2XSY : Benefits and Features
Why XLPE? It’s simple: Low dielectric loss and a 90°C operating temp. This gives you way more thermal headroom than older PVC cables, meaning you can push higher loads safely.
Installer Friendly: The PVC jacket is formulated to be flexible. It makes wrestling the cable into tight switchgear or ducts a lot less of a headache compared to stiff PE sheaths.
Fast Jointing: We use a fully strippable semi-con screen. Your jointers will love this because they can strip it cleanly by hand without needing expensive shaving tools or risking damage to the insulation.
Safety Screen: O Copper Wire Screen (with the helix tape) isn’t just for shielding—it provides the necessary low-impedance path for earth fault currents to trip your protection gear instantly.
Dimensões/Parâmetros
| Cross sectional area (mm2) | Conductor Structure | Conductor Outer diameter (mm) | Insulation thickness (mm) | Copper tape screen (approximate) (mm) | Sheath thickness (mm) | Outer diameter (approximate) (mm) | Copper core cableweight (kg/km) | Aluminum core cableweight (kg/km) |
|---|---|---|---|---|---|---|---|---|
| 25 | Compact round | 6.0 | 2.5 | 0.12 | 1.5 | 17.2 | 510 | 354 |
| 35 | Compact round | 7.2 | 2.5 | 0.12 | 1.6 | 18.6 | 637 | 418 |
| 50 | Compact round | 8.4 | 2.5 | 0.12 | 1.6 | 19.8 | 800 | 488 |
| 70 | Compact round | 10.0 | 2.5 | 0.12 | 1.7 | 21.6 | 1029 | 591 |
| 95 | Compact round | 11.7 | 2.5 | 0.12 | 1.7 | 23.3 | 1296 | 701 |
| 120 | Compact round | 13.1 | 2.5 | 0.12 | 1.8 | 24.9 | 1566 | 815 |
| 150 | Compact round | 14.6 | 2.5 | 0.12 | 1.8 | 26.4 | 1873 | 934 |
| 185 | Compact round | 16.3 | 2.5 | 0.12 | 1.9 | 28.3 | 2244 | 1085 |
| 240 | Compact round | 18.5 | 2.6 | 0.12 | 1.9 | 30.7 | 2805 | 1302 |
| 300 | Compact round | 20.7 | 2.8 | 0.12 | 2.0 | 33.7 | 3456 | 1576 |
| 400 | Compact round | 23.8 | 3.0 | 0.12 | 2.2 | 37.4 | 4501 | 1994 |
| 500 | Compact round | 26.6 | 3.2 | 0.12 | 2.3 | 41.4 | 5546 | 2412 |
| 630 | Compact round | 30.1 | 3.2 | 0.12 | 2.4 | 45.1 | 6853 | 2905 |
| 800 | Compact round | 35.0 | 3.2 | 0.12 | 2.5 | 50.4 | 8576 | 3562 |
| 1000 | Milliken conductor | 39.5 | 3.2 | 0.12 | 2.6 | 55.3 | 10592 | 4306 |
| Cross sectional area (mm2) | Conductor Structure | Conductor Outer diameter (mm) | Insulation thickness (mm) | Copper tape screen (approximate) (mm) | Sheath thickness (mm) | Outer diameter (approximate) (mm) | Copper core cableweight (kg/km) | Aluminum core cable weight (kg/km) |
|---|---|---|---|---|---|---|---|---|
| 25 | Compact round | 6.0 | 3.4 | 0.12 | 1.6 | 19.4 | 580 | 423 |
| 35 | Compact round | 7.2 | 3.4 | 0.12 | 1.6 | 20.6 | 702 | 483 |
| 50 | Compact round | 8.4 | 3.4 | 0.12 | 1.7 | 22.0 | 878 | 566 |
| 70 | Compact round | 10.0 | 3.4 | 0.12 | 1.7 | 23.6 | 1103 | 665 |
| 95 | Compact round | 11.7 | 3.4 | 0.12 | 1.8 | 25.5 | 1386 | 791 |
| 120 | Compact round | 13.1 | 3.4 | 0.12 | 1.8 | 26.9 | 1649 | 898 |
| 150 | Compact round | 14.6 | 3.4 | 0.12 | 1.9 | 28.6 | 1974 | 1035 |
| 185 | Compact round | 16.3 | 3.4 | 0.12 | 1.9 | 30.3 | 2337 | 1178 |
| 240 | Compact round | 18.5 | 3.4 | 0.12 | 2.0 | 32.7 | 2908 | 1406 |
| 300 | Compact round | 20.7 | 3.4 | 0.12 | 2.1 | 35.3 | 3544 | 1664 |
| 400 | Compact round | 23.8 | 3.4 | 0.12 | 2.2 | 38.6 | 4554 | 2047 |
| 500 | Compact round | 26.6 | 3.4 | 0.12 | 2.3 | 42.2 | 5574 | 2440 |
| 630 | Compact round | 30.1 | 3.4 | 0.12 | 2.4 | 45.9 | 6884 | 2936 |
| 800 | Compact round | 35.0 | 3.4 | 0.12 | 2.5 | 51.2 | 8611 | 3597 |
| 1000 | Milliken conductor | 39.5 | 3.4 | 0.12 | 2.7 | 56.3 | 10655 | 4369 |
| Conductor Cross sectional area (mm2) | Conductor Structure | Conductor Outer diameter (mm) | Insulation thickness (mm) | Copper tape screen (approximate) (mm) | Sheath thickness (mm) | Outer diameter (approximate) (mm) | Copper core cable weight (kg/km) | Aluminum core cable weight (kg/km) |
|---|---|---|---|---|---|---|---|---|
| 35 | Compact round | 7.2 | 5.5 | 0.12 | 1.8 | 25.2 | 896 | 677 |
| 50 | Compact round | 8.4 | 5.5 | 0.12 | 1.8 | 26.4 | 1071 | 759 |
| 70 | Compact round | 10.0 | 5.5 | 0.12 | 1.9 | 28.2 | 1320 | 882 |
| 95 | Compact round | 11.7 | 5.5 | 0.12 | 1.9 | 29.9 | 1604 | 1009 |
| 120 | Compact round | 13.1 | 5.5 | 0.12 | 2.0 | 31.5 | 1892 | 1141 |
| 150 | Compact round | 14.6 | 5.5 | 0.12 | 2.0 | 33.0 | 2215 | 1275 |
| 185 | Compact round | 16.3 | 5.5 | 0.12 | 2.1 | 34.9 | 2605 | 1447 |
| 240 | Compact round | 18.5 | 5.5 | 0.12 | 2.2 | 37.3 | 3196 | 1693 |
| 300 | Compact round | 20.7 | 5.5 | 0.12 | 2.2 | 39.7 | 3833 | 1953 |
| 400 | Compact round | 23.8 | 5.5 | 0.12 | 2.3 | 43.0 | 4867 | 2360 |
| 500 | Compact round | 26.6 | 5.5 | 0.12 | 2.4 | 46.6 | 5902 | 2769 |
| 630 | Compact round | 30.1 | 5.5 | 0.12 | 2.5 | 50.3 | 7250 | 3302 |
| 800 | Compact round | 35.0 | 5.5 | 0.12 | 2.7 | 55.8 | 9040 | 4026 |
| 1000 | Milliken conductor | 39.5 | 5.5 | 0.12 | 2.8 | 60.7 | 11096 | 4810 |
| Conductor Cross sectional area (mm2) | Conductor Structure | Conductor Outer diameter (mm) | Insulation thickness (mm) | Copper tape screen (approximate) (mm) | Sheath thickness (mm) | Outer diameter (approximate) (mm) | Copper core cable weight (kg/km) | Aluminum core cable weight (kg/km) |
|---|---|---|---|---|---|---|---|---|
| 50 | Compact round | 8.4 | 8.0 | 0.12 | 2.0 | 31.8 | 1354 | 1042 |
| 70 | Compact round | 10.0 | 8.0 | 0.12 | 2.0 | 33.4 | 1604 | 1166 |
| 95 | Compact round | 11.7 | 8.0 | 0.12 | 2.1 | 35.3 | 1918 | 1323 |
| 120 | Compact round | 13.1 | 8.0 | 0.12 | 2.1 | 36.7 | 2204 | 1453 |
| 150 | Compact round | 14.6 | 8.0 | 0.12 | 2.2 | 38.4 | 2557 | 1617 |
| 185 | Compact round | 16.3 | 8.0 | 0.12 | 2.2 | 40.1 | 2946 | 1788 |
| 240 | Compact round | 18.5 | 8.0 | 0.12 | 2.3 | 42.5 | 3557 | 2055 |
| 300 | Compact round | 20.7 | 8.0 | 0.12 | 2.4 | 45.1 | 4236 | 2355 |
| 400 | Compact round | 23.8 | 8.0 | 0.12 | 2.5 | 48.4 | 5299 | 2792 |
| 500 | Compact round | 26.6 | 8.0 | 0.12 | 2.6 | 52.0 | 6354 | 3220 |
| 630 | Compact round | 30.1 | 8.0 | 0.12 | 2.7 | 55.7 | 7748 | 3799 |
| 800 | Compact round | 35.0 | 8.0 | 0.12 | 2.8 | 61.0 | 9560 | 4546 |
| 1000 | Milliken conductor | 39.5 | 8.0 | 0.12 | 3.0 | 66.1 | 11687 | 5401 |
| Conductor Cross sectional area (mm2) | Conductor Structure | Conductor Outer diameter (mm) | Insulation thickness (mm) | Copper tape screen (approximate) (mm) | Sheath thickness (mm) | Outer diameter (approximate) (mm) | Copper core cable weight (kg/km) | Aluminum core cable weight (kg/km) |
|---|---|---|---|---|---|---|---|---|
| 50 | Compact round | 8.4 | 9.3 | 0.12 | 2.1 | 34.8 | 1533 | 1221 |
| 70 | Compact round | 10.0 | 9.3 | 0.12 | 2.1 | 36.4 | 1791 | 1353 |
| 95 | Compact round | 11.7 | 9.3 | 0.12 | 2.2 | 38.3 | 2115 | 1520 |
| 120 | Compact round | 13.1 | 9.3 | 0.12 | 2.2 | 39.7 | 2408 | 1656 |
| 150 | Compact round | 14.6 | 9.3 | 0.12 | 2.3 | 41.4 | 2769 | 1830 |
| 185 | Compact round | 16.3 | 9.3 | 0.12 | 2.3 | 43.1 | 3167 | 2009 |
| 240 | Compact round | 18.5 | 9.3 | 0.12 | 2.4 | 45.5 | 3790 | 2287 |
| 300 | Compact round | 20.7 | 9.3 | 0.12 | 2.5 | 48.1 | 4481 | 2601 |
| 400 | Compact round | 23.8 | 9.3 | 0.12 | 2.6 | 51.4 | 5561 | 3054 |
| 500 | Compact round | 26.6 | 9.3 | 0.12 | 2.7 | 57.1 | 6894 | 3760 |
| 630 | Compact round | 30.1 | 9.3 | 0.12 | 2.8 | 60.8 | 8263 | 4314 |
| 800 | Compact round | 35.0 | 9.3 | 0.12 | 3.0 | 66.3 | 10257 | 5243 |
| 1000 | Milliken conductor | 39.5 | 9.3 | 0.12 | 3.1 | 71.2 | 12369 | 6083 |
| Conductor Cross sectional area (mm2) | Conductor Structure | Conductor Outer diameter (mm) | Insulation thickness (mm) | Copper tape screen (approximate) (mm) | Sheath thickness (mm) | Cable Outer diameter (approximate) (mm) | Copper core cableweight (kg/km) | Aluminum core cable weight (kg/km) |
|---|---|---|---|---|---|---|---|---|
| 50 | Compact round | 8.4 | 10.5 | 0.12 | 2.2 | 37.6 | 1715 | 1402 |
| 70 | Compact round | 10.0 | 10.5 | 0.12 | 2.2 | 39.2 | 1980 | 1541 |
| 95 | Compact round | 11.7 | 10.5 | 0.12 | 2.3 | 41.1 | 2313 | 1718 |
| 120 | Compact round | 13.1 | 10.5 | 0.12 | 2.3 | 42.5 | 2612 | 1860 |
| 150 | Compact round | 14.6 | 10.5 | 0.12 | 2.4 | 44.2 | 2981 | 2042 |
| 185 | Compact round | 16.3 | 10.5 | 0.12 | 2.4 | 45.9 | 3387 | 2229 |
| 240 | Compact round | 18.5 | 10.5 | 0.12 | 2.5 | 48.3 | 4021 | 2519 |
| 300 | Compact round | 20.7 | 10.5 | 0.12 | 2.6 | 50.9 | 4725 | 2845 |
| 400 | Compact round | 23.8 | 10.5 | 0.12 | 2.7 | 54.2 | 5820 | 3313 |
| 500 | Compact round | 26.6 | 10.5 | 0.12 | 2.8 | 59.7 | 7142 | 4009 |
| 630 | Compact round | 30.1 | 10.5 | 0.12 | 2.9 | 63.4 | 8528 | 4579 |
| 800 | Compact round | 35.0 | 10.5 | 0.12 | 3.1 | 68.7 | 10521 | 5507 |
| 1000 | Milliken conductor | 39.5 | 10.5 | 0.12 | 3.2 | 73.6 | 12652 | 6366 |
-
Processos de produção de cabos de alimentação
Para assegurar a qualidade superior, JOCA opera linhas de produção totalmente digitalizadas e automatizadas para cabos alimentação. Especificamente, este fluxo de trabalho abrangente capas encalhe do condutor, extrusão da isolação, triagem metálica, e revestimento final. Além disso, sistemas inteligentes monitore ativamente cada etapa para garantir um desempenho estável e uma qualidade consistente do produto. Além disso, a fábrica utiliza instalações de teste avançadas, como testes de descarga parcial, testes de tração e testes de faísca. Consequentemente, estas medidas rigorosas garantia que cada cabo entregue cumpre restritamente padrões internacionais.
Embalagem para envio
Para atender a várias necessidades de transporte, existem muitos métodos de embalagem que podem ser usados.
Tem mais perguntas?
P: N2XSY vs. NA2XSY: Qual é a diferença?
R: Apenas o metal condutor. N2XSY é Cobre. NA2XSY (with the ‘A’) is Aluminum. É isso. O alumínio é muito mais barato e leve, enquanto o cobre carrega mais carga.
Q: Que tensão esta cobre?
R: Toda a faixa de Tensão Média. Começa em 3,6kV, vai direto para 35kV.
Q: What’s the sheath material?
R: Padrão PVC. It’s flexible, which saves you a lot of trouble when pulling it through indoor conduits or tight trays.
Q: Can I bury this directly in the ground?
R: Technically, yes, if it’s dry. But honestly? For direct burial, you really should ask for the PE sheath version (N2XS2Y). It handles wet soil way better than PVC. Don’t risk it if the ground is swampy.
Q: What colors do you have?
R: Mostly Vermelho ou Preto. Need something else? We can run a custom batch for you, just ask.
Q: Is the insulation screen strippable?
R: Fully Strippable. Your jointers will thank you. It peels off clean by hand—no need for those expensive shaving tools.
Q: Can I get a sample?
R: Sim. We can ship a short cut so you can inspect the layers and quality yourself before buying a full drum.
Q: Is the conductor solid or stranded?
R: Class 2 Stranded (Compacted). It keeps the cable diameter tight but still flexible enough to handle.