Fraud Blocker

JOCA

Search
Close this search box.

UL4703 DC1500V EN 50618 Double Certificate Solar Cable

EN 50618 UL4703 Double Certificate Solar Cable-JOCA

  • Ground-mount/Rooftop/ Floating Photovoltaic Power Plants
  • TUV/UL/IEC/CE/Ad8/CPR Certificated & 25 Years Global Lifespan
  • Indoor and Outdoor Environment after Electron Irradiation that are Harsh are Suited to It.
  • All Major Solar Connectors can be Connected to this Device
  • Within 200km radius of Lagos. 7 days after placing order

 Save at least 30% on average

UL4703 DC1500V EN 50618 Double Certificate Solar Cable
  • icon

    Product Description

    UL4703 DC1500V EN 50618 Double Certificate Solar Cable : Product Description and Specifications

The solar cable UL4703, DC1500V, EN50618 Double Certificate is designed to be flexible and connect photovoltaic systems. It has TUV, UL, IEC and CE certificates from around the world including UL4703, IEC62930, EN50618, Ad8 and CPR standards. This solar cable suits various solar power environments including roofs, deserts, lakes and mountains with harsh conditions. Its stable connection performance ensures safe long-term operation while reducing system failure rates and operation costs. It can be used to stay on track with efficient and secure PV installations that are highly profitable in the long run.

Advantages
  • icon

    Advantages

    UL4703 DC1500V EN 50618 Double Certificate Solar Cable : Benefits and Features

a. Chemicals cross-linked with electron beams

b. They are resistant to UV, ozone and hydrolysis.

c. The materials do not melt or flow when exposed to high temperature.

d. Have good flexibility in cold weather.

e. >25 years service life at 90°C

f. Fits all popular connectors

Specification Of UL4703 DC1500V EN 50618 Double Certificate Solar Cable

Cable Construction
ConductorClass 5 Tinned copper, according to the EN 60228 and IEC 60228
InsulationHalogen-free electron-beam cross-linked Polyolefin copolymer (XLPO)
Outer SheathHalogen-free electron-beam cross-linked Polyolefin copolymer(XLPO), Flame Retardant Compound
Sheath colorBlack/Red
Nominal VoltageUO/U 600/1000V(AC) , 1500V(DC)
Test VoltageAC 6500v, 50HZ, 10Min(20±0.5℃)or DC 15000v,10 Min (20±0.5℃) Without Broken
Temperature RatingWorking temperature -40℃~+90℃,Max conductor temperature 120℃(20000H)
Service LifeExpected life span≥25 years
Bending Radius5D (D: Cable diameter)
Fire-resistant PerformanceEN 60332-1-2
Smoke EmissionBased on UNE-EN 60754-2 and IEC 60754-2.
European CPRCca ,according to En 50575
Water PerformanceAd8
Weather Resistance/UV ResistanceEN 50289-4-17/ENISO4892
Halogen DeterminationEN 50525
CertificationTUV/UL//IEC/CE/RoHS

Dimensions/Parameters

Construction (n×mm2)Conductor Construction(n x mm)Insulation Normal Thickness(mm)Sheath Normal Thickness(mm)Outer Diameter(mm)Max DC Resistance of Conductor at 20℃ (Ω/Km)Min Insulation Resistance at 90℃ (mΩ/Km)Current Carrying Capacity(A)
1x1.5(16AWG)30x0.240.70.84.613.70.8630
1x2.5(14AWG)49x0.240.70.858.210.6941
1x4.0(12AWG)56x0.280.70.85.555.090.5855
1x6(10AWG)78x0.290.70.86.153.390.570
1x10(8AWG)77x0.390.70.87.41.950.4298
1x16(6AWG)126x0.390.70.98.521.240.34132
1x25(4AWG)189x0..390.9110.60.7950.34176
1x35(2AWG)276x0.390.91.112.50.5650.29218
1x50(1/0AWG)396x0.3911.214.20.3930.27280

Certifications Of EN50618 UL4703 Double Certificate Solar Cable

Certifications Of CPR CCA H1Z2Z2-K Solar Cable
  • icon

    Production Processes Of Photovoltaic Wire

JOCA cable factory’s use of state-of-the-art digital infrastructure is revolutionizing its production and inspection processes. This digitization system, which is smart in nature, helps minimize mistakes as well as eliminate defects thus improving the dependability of products to a great extend. It utilizes advanced tools like smart digital image sensing systems and lasers for inspection to guarantee that their products are always of the first class.

Production Processes Of Photovoltaic Wire

Packing For Shipment

Various packaging methods tailored to diverse transport conditions.

Packing PicturesPacking Method Qty/pallet(pcs)Meter/pallet (M)G.W/pallet(KGS)Pallet size (m)Pallet/20GPMeter/20GP
packing100M/ROLL4mm²-176pcs4mm²-17600m4mm²-1144kgs1.12x1.12x1.12m204mm²-352000m
6mm²-160pcs6mm²-16000m6mm²-1360kgs6mm²-320000m
packing200M/ROLL4mm²-90pcs4mm²-18000m4mm²-1170kgs1.12x1.12x1.12m204mm²-360000m
6mm²-81pcs6mm²-16200m6mm²-1377kgs6mm²-324000m
packing100m/plastic drum4mm²-125pcs4mm²-12500m4mm²-850kgs1.12x1.12x1.12m204mm²-250000m
6mm²-100pcs6mm²-10000m6mm²-900kgs6mm²-200000m
packing500m/wood drum4mm²-27pcs4mm²-13500m4mm²-1197kgs1.12x1.12x1.12204mm²-270000m
6mm²-27pcs6mm²-13500m6mm²-930kgs6mm²-270000m
packing1000M/wood drum4mm²-12pcs4mm²-12000m4mm²-830kgs1.12x1.12x1.12204mm²-240000m
6mm²-12pcs6mm²-12000m6mm²-1070kgs6mm²-240000m
Packing For Shipment

Have more questions?

Find answers to frequently asked questions about our company and services for a seamless beginning.

Q: What is UL4703 DC1500V EN 50618 Double Certificate Solar Cable?

A: UL4703 DC1500V EN 50618 Double Certificate Solar Cable is a premium solar cable exclusively designed for connecting photovoltaic system components both indoors and outdoors. This solar cable has two certifications: the UL4703 and EN50618 standards which validate its safety and performance in solar PV systems.

Q: What makes this solar cable suitable for solar photovoltaic system applications?

A: Its high DC1500V rating means it is ideal for connecting photovoltaic system parts, especially with its good UV and ozone resistance as well as robust insulation that can withstand large changes in temperature. Its tinned copper strands also provide optimal conductivity while protecting against corrosion, making them suitable for use in PV systems.

Q: Are UL4703 DC1500V EN 50618 certified cables necessary for my solar PV system?

A: Yes, your solar PV must have cables that are UL4703 and EN50618 certified. These indicate that the wires fulfil certain criteria like safety, durability, and quality thus ensuring that all the components of the system are of good quality hence efficient running of the whole photovoltaic plant.

Q: Can this solar cable be used for both AC and DC applications within a solar PV system?

A: It is important to ensure compatibility with your specific requirements even though UL4703 DC1500V EN 50618 Double Certificate Solar Cable is typically used for linking panels to inverters like other direct currents (DC) connections found within most plants. However, when connecting with alternating current (AC), use specifically rated cables meant for AC purpose only so as to enhance efficiency and security of the system.

Q: What are the benefits of using a cable with double certification in my solar system installation?

A: In addition to meeting international safety guidelines as well as quality parameters; double-certified cables such as those certified by UL4703 &EN50618 offer an added advantage of being able to withstand harsh environments without performance compromise. Moreover, the double certification is an indication that the product has been tested extensively and therefore can be trusted and relied on by system integrators and clients.

Q: How important is the temperature rating of a solar cable?

A: The temperature rating of a solar cable is highly critical in determining its efficient operation under extreme temperature changes typical for solar PV systems. A solar cable like UL4703 DC1500V EN 50618 Double Certificate Solar Cable which is designed to resist high temperatures would ensure that the system operates smoothly over time hence reducing instances of failure occasioned by overheating or insulation breakdown.

Q: Is this solar cable resistant to UV and ozone damage?

A: Exactly so! The UL4703 DC1500V EN 50618 Double Certificate Solar Cable are manufactured with UV and ozone resistant properties. For this reason, it can endure harmful effects related to sun exposure as well as different environmental factors. In view of this, these cables are highly resilient meaning that they can be used indoors or outdoors in the harsh weather experienced in most solar PV systems where such cables are used.

Scroll to Top
Get in touch with JOCA company

Kindly complete the form below to reach out to us. We aim to get back to you within 12 hours. Wishing you the very best!

Contact Form Demo

JOCA