Fraud Blocker

JOCA

Search
Close this search box.

CPR CCA DC1500V EN 50618 H1z2z2-k Solar Cable

European Standard Fire-Resistant Solar Cable for TUV CPR CCA DC1500V EN 50618 H1Z2Z2-K Systems

  • Applied on the ground / top of a building/top-of-the-air PV power plants.
  • TUV/UL/IEC/CE/Ad8/CPR certified with 25 years life span
  • Suitable for use in extreme indoor and outdoor environment after electron irradiation
  • It’s working with all major solar connectors
  • Within 200km, delivery is guaranteed within 7 days.

 Save at least 30% on average

CPR CCA DC1500V EN 50618 H1z2z2-k Solar Cable
  • icon

    Product Description

    Solar Cable CPR CCA DC1500V EN 50618 H1z2z2-k: Product Description and Specifications

The H1Z2Z2-K solar cable CPR CCA Fire-resistant DC1500V EN 50618 is designed to be flexible so that it can fit into a PV solar system. It meets the standards of various organizations such as TUV, UL, IEC and CE; under these certifications also include CPR, Ad8, EN50618, IEC62930 and UL4703. Large-scale solar stations, rooftop installations and water-surface stations are all good examples of where it can be used. Over time in the industry this has been found to be very useful in areas like roofs within residential areas or even deserts or lakes near seasides. Thus ensures stable connection performance for long-term PV system safety while reducing failure rates and operational costs. This guarantees sustainable profits by optimizing PV installations safely and efficiently.

Advantages
  • icon

    Advantages

    Advantages of CPR-certified CCA DC1500V EN 50618 H1z2z2-k Solar Cable: Benefits and Features

a. Compounds with cross-linking by electron beams

b. UV, ozone and water resistant

c. Having a high temperature resistance, these materials do not melt or flow

d. Well resistant to low temperatures

e. Very long service life > 25 years at 90 c

f. It is compatible with all widely used connectors

CPR CCA H1Z2Z2-K Solar Cable with Fire Resistance Specification

Cable Construction
ConductorClass 5 Tinned copper, according to the EN 60228 and IEC 60228
InsulationHalogen-free electron-beam cross-linked Polyolefin copolymer (XLPO)
Outer SheathHalogen-free electron-beam cross-linked Polyolefin copolymer(XLPO), Flame Retardant Compound
Sheath colorBlack/Red
Nominal VoltageUO/U 600/1000V(AC) , 1500V(DC)
Test VoltageAC 6500v, 50HZ, 10Min(20±0.5℃)or DC 15000v,10 Min (20±0.5℃) Without Broken
Temperature RatingWorking temperature -40℃~+90℃,Max conductor temperature 120℃(20000H)
Service LifeExpected life span≥25 years
Bending Radius5D (D: Cable diameter)
Fire-resistant PerformanceEN 60332-1-2
Smoke EmissionBased on UNE-EN 60754-2 and IEC 60754-2.
European CPRCca ,according to En 50575
Water PerformanceAd8
Weather Resistance/UV ResistanceEN 50289-4-17/ENISO4892
Halogen DeterminationEN 50525
CertificationTUV/UL//IEC/CE/RoHS

Dimensions/Parameters

Construction (n×mm2)Conductor Construction(n x mm)Insulation Normal Thickness(mm)Sheath Normal Thickness(mm)Outer Diameter(mm)Max DC Resistance of Conductor at 20℃ (Ω/Km)Min Insulation Resistance at 90℃ (mΩ/Km)Current Carrying Capacity(A)
1×1.5(16AWG)30x0.240.70.84.613.70.8630
1×2.5(14AWG)49x0.240.70.858.210.6941
1×4.0(12AWG)56x0.280.70.85.555.090.5855
1×6(10AWG)78x0.290.70.86.153.390.570
1×10(8AWG)77x0.390.70.87.41.950.4298
1×16(6AWG)126x0.390.70.98.521.240.34132
1x25(4AWG)189x0..390.9110.60.7950.34176
1x35(2AWG)276x0.390.91.112.50.5650.29218
1x50(1/0AWG)396x0.3911.214.20.3930.27280

Certifications Of CPR CCA H1Z2Z2-K Solar Cable

Certifications Of CPR CCA H1Z2Z2-K Solar Cable
  • icon

    Production Processes Of Photovoltaic Wire

The cable factory at JOCA has a digital factory that is advanced in nature, making it possible to smooth out the production and inspection processes. Eliminating mistakes from hand assembly enhances product reliability through this digital setup, and achieves high levels of quality using modern technologies such as image recognition.

Production Processes Of Photovoltaic Wire

Packing For Shipment

There are numerous packaging techniques that can be used to cater for different transportation requirements.

Packing PicturesPacking Method Qty/pallet(pcs)Meter/pallet (M)G.W/pallet(KGS)Pallet size (m)Pallet/20GPMeter/20GP
packing100M/ROLL4mm²-176pcs4mm²-17600m4mm²-1144kgs1.12x1.12x1.12m204mm²-352000m
6mm²-160pcs6mm²-16000m6mm²-1360kgs6mm²-320000m
packing200M/ROLL4mm²-90pcs4mm²-18000m4mm²-1170kgs1.12x1.12x1.12m204mm²-360000m
6mm²-81pcs6mm²-16200m6mm²-1377kgs6mm²-324000m
packing100m/plastic drum4mm²-125pcs4mm²-12500m4mm²-850kgs1.12x1.12x1.12m204mm²-250000m
6mm²-100pcs6mm²-10000m6mm²-900kgs6mm²-200000m
packing500m/wood drum4mm²-27pcs4mm²-13500m4mm²-1197kgs1.12x1.12x1.12204mm²-270000m
6mm²-27pcs6mm²-13500m6mm²-930kgs6mm²-270000m
packing1000M/wood drum4mm²-12pcs4mm²-12000m4mm²-830kgs1.12x1.12x1.12204mm²-240000m
6mm²-12pcs6mm²-12000m6mm²-1070kgs6mm²-240000m
Packing For Shipment

Have more questions?

Find answers to frequently asked questions about our company and services for a seamless beginning.

Q: What are the key properties of the H1Z2Z2-K Solar Cable according to EN 50618 standards?

A: The H1Z2Z2-K solar cable, EN 50618 certified, has various essential characteristics that make it fit for photovoltaic systems. It is made for 1500V DC applications ensuring efficiency and safety. This flexible single-core cable has a cross-linked insulation and jacket material hence great UV, ozone and other outdoor elements resistances. It’s built to last with high temperature and water performance rating making it suitable for rooftop solar installation and floating solar farms.of each industry.

Q: Can H1Z2Z2-K solar cables be used for direct burial applications?

A: Certainly, H1Z2Z2-K solar cables can be directly buried. They have AD8 water performance requirement meaning they can remain submerged under water thus allowing them to be used in underground installations without having to buy additional conduits or covers. For example in solar power plants on ground where direct burial can simplify installation & durability enhancement.of each industry.

Q: How does the CPR CCA classification affect the usage of H1Z2Z2-K solar cables?

A: The Construction Products Regulation (CPR) CCA classification on H1Z2Z2-K Solar Cables defines its fire behavior as per EU regulations. This guarantees that not only does it meet all high security requirements by limiting its flame spread in case of combustion but it is also good for use in homes, offices as well as factories. The CPR CCA rating offers confidence regarding what might happen if there was a fire showing that this type of wire is much better suited to roofs when compared with inside spaces found within solar powered systems buildings.of each industry.

Q: Can H1Z2Z2-K solar cables be used in high temperature areas?

A: Yes, H1Z2Z2-K solar cables are designed primarily for use in high-temperature environments. They are made of materials that maintain their flexibility even at high temperatures and provide good performance, ensuring reliable connection between solar panels and the inverter. The temperature characteristics of these wires make them suitable for highly insolated areas with high ambient temperatures, which promotes efficiency and durability of the entire solar installation.

Q: What certification standards do EN 50618 H1Z2Z2-K solar cables meet?

A: EN 50618 H1Z2Z2-K solar cables meet a wide range of different standard requirements such as EN 50618 on Solar Cables, TÜV and UL certifications. These certificates confirm quality assurance, safety and suitability to photovoltaic systems respectively. With TÜV certification recognizing conformity with European norms and UL certification establishes its safe use in the US. By adhering to these directives on manufacture of the H1Z2z2-k; it makes it possible to use these cables universally hence improving compatibility as well as security.of each industry.

Q: Why are H1Z2Z2-K solar cables best suited for rooftop installations?

A: Highly flexible, easy to install in complicated rooftop layouts often characterizing solar power installations, is a feature that distinguishes how suitable the H1Z2Z2-K type is for such arrangements. The needs of the PV industry such as mechanical, temperature and water performance including resistance against UV light and ozone have been met through this design with an objective of improving durability among others. Additionally, direct burial (AD8) rated along with high-temperature usage ensure they can withstand severe rooftop conditions like exposure to direct sunlight or varying weather patterns. It’s also important for installers &homeowners alike to know about safety features plus certifications too.

Q: Can H1Z2Z2-K solar cables be used in both commercial and residential solar systems?

A: Certainly, H1Z2Z2-K solar cables are versatile and can be used in both commercial and residential solar systems. Their robustness as per EN 50618 standard for Solar Cables makes them suitable for large-scale commercial solar farms and small residential rooftop installations.The cables perform different functions within a photovoltaic system such as interconnecting panels, linking panels to inverters or extending connections within an array.It also means that these products can be used across a broad scope of applications within the photovoltaic industry including but not limited to; connecting individual solar modules that constitute a string(s) and providing extension between strings.

Q: What kind of support is available for customers buying H1Z2Z2-K solar cables?

A: There are comprehensive sales supports available from manufacturers, suppliers when customers purchase H1Z2Z2-K types of wires. These include technical advice on product selection to meet specific application requirements, installation guidance as well as after-sales support among others. Manufacturers often provide documentation such as data sheets about their products plus installation manuals which ensures appropriate or safe utilization of their wires. Asking questions, ordering help and addressing post-purchase issues are some of the customer services offered by reputable suppliers throughout the process of procuring and using these items.

Scroll to Top
Get in touch with JOCA company

Kindly complete the form below to reach out to us. We aim to get back to you within 12 hours. Wishing you the very best!

Contact Form Demo

JOCA