Es-H15Z-F TUV Energy Storage Cable Battery Cable
- Applicable to Solar Power Stations on the Ground /Roof/ Floating
- Certified by TUV/UL/IEC/CE/Ad8/CPR & Lasting for 25 years
- It is used for connecting the battery, battery pack, or combination box with the power conversion system in the solar storage system.
- Suitable for any type of rechargeable battery
- Delivery within 7 work days, if you are within 200 km.
- Fast Sample Processing with Customized Solutions
- High-Quality Materials
- Affordable Price Options
- Global Delivery
- For better data protection, make sure that all uploads are secure
Save at least 30% on average
Home » Energy Storage Cable » Es-H15Z-F TUV Energy Storage Cable Battery Cable
-
Product Description
Es-H15Z-F TUV Certified DC1500V Energy battery and inverter Storage Cable:Product Description and Specifications
Approved by TUV Es-H15Z-F DC1500V Energy battery and inverter Storage Cable is a flexible type of cable that is mainly used for solar storage systems. It is applicable to various fields of solar energy such as large-scale solar power stations, rooftop photovoltaic power stations and water surface floating power stations. This multi-purpose solar cable has been designed to meet the different requirements of the solar industry. It can be used for internal wiring of electronic ,electrical equipment ,such as between battery and inverter connect used for solar storage system. Photovoltaic systems with long-term safety operation stability are guaranteed by stable and good connecting performance thus it helps to reduce the failure rate and later operation cost of PV system effectively. We will help you get your PV installations up and running quickly, efficiently, and safely – ensuring sustainable profitability from your investment in photovoltaics (PV).
-
Advantages
Discover the benefits of Es-H15Z-F TUV Energy Storage Cable Battery Cable - a reliable energy storage solution with top-notch performance.
a. Compounds cross-linked by an electron beam
b. Resistant to UV, ozone and hydrolysis.
c. They can withstand high temperatures without melting or flowing.
d. Excellent flexibility at low temperatures
e. have a very long service life. More than 25 years at 90 c
Specification Of Es-H15z-F Energy battery Storage Cable
Cable Construction | |
---|---|
Conductor | Class 5 tinned copper or bare copper wire |
Insulation | XLPO |
Nominal Voltage | DC 1500V |
Test Voltage | 4500v |
Temperature Rating | 125℃ |
Service Life | Expected life span≥25 years |
Certification | CQC1143,Ppp58049A |
Dimensions/Parameters
Conductor | Insulation | ||||
---|---|---|---|---|---|
mm² | No./mm | Nom.Dia (mm) | Nom. Thick (mm) | Nom. Dia (mm) | MAX.COND Resistance (Ω/km, 20°C, DC) |
4 | 56/0.30 | 2.59 | 0.8 | 4.25 | 5.09 |
6 | 84/0.30 | 3.17 | 0.8 | 4.85 | 3.39 |
10 | 78/0.40 | 4.08 | 1 | 5.9 | 1.95 |
16 | 126/0.40 | 5.59 | 1.1 | 7.9 | 1.24 |
25 | 196/0.40 | 6.95 | 1.3 | 9.7 | 0.795 |
35 | 276/0.40 | 8.3 | 1.3 | 11 | 0.565 |
50 | 396/0.40 | 9.9 | 1.5 | 13 | 0.393 |
70 | 553/0.40 | 11.7 | 1.5 | 14.8 | 0.277 |
95 | 760/0.40 | 13.87 | 1.5 | 17 | 0.21 |
120 | 950/0.40 | 15.5 | 1.5 | 18.6 | 0.164 |
150 | 1178/0.40 | 17.26 | 1.7 | 20.9 | 0.132 |
185 | 1463/0.40 | 19.24 | 1.9 | 23.2 | 0.108 |
240 | 1911/0.40 | 23.4 | 2 | 27.6 | 0.0817 |
Certifications Of Es-H15z-F Energy battery Storage Cable
-
Production Processes Of Es-H15z-F Energy battery Storage Cable
The JOCA cable factory is home to a smart factory that is digital and intelligent. This means that the process of production as well as inspection are integrated into one system which is digitalized. Unlike before where workers made things by hand so there were errors or faults; now everything is done automatically with computers so mistakes are avoided at all costs plus it makes the goods produced more dependable. Additionally, this place has got all tools necessary for examining what’s been created such as complete inspection and testing equipment along with some other methods like using lasers or digital intelligent image detection etc., which can be applied during checking out products before they are shipped off somewhere else.
Packing For Shipment
Various packaging methods designed to cater to different transportation conditions.
Packing Pictures | Packing Method | Qty/pallet(pcs) | Meter/pallet (M) | G.W/pallet(KGS) | Pallet size (m) | Pallet/20GP | Meter/20GP |
---|---|---|---|---|---|---|---|
100M/ROLL | 4mm²-176pcs | 4mm²-17600m | 4mm²-1144kgs | 1.12x1.12x1.12m | 20 | 4mm²-352000m | |
6mm²-160pcs | 6mm²-16000m | 6mm²-1360kgs | 6mm²-320000m | ||||
200M/ROLL | 4mm²-90pcs | 4mm²-18000m | 4mm²-1170kgs | 1.12x1.12x1.12m | 20 | 4mm²-360000m | |
6mm²-81pcs | 6mm²-16200m | 6mm²-1377kgs | 6mm²-324000m | ||||
100m/plastic drum | 4mm²-125pcs | 4mm²-12500m | 4mm²-850kgs | 1.12x1.12x1.12m | 20 | 4mm²-250000m | |
6mm²-100pcs | 6mm²-10000m | 6mm²-900kgs | 6mm²-200000m | ||||
500m/wood drum | 4mm²-27pcs | 4mm²-13500m | 4mm²-1197kgs | 1.12x1.12x1.12 | 20 | 4mm²-270000m | |
6mm²-27pcs | 6mm²-13500m | 6mm²-930kgs | 6mm²-270000m | ||||
1000M/wood drum | 4mm²-12pcs | 4mm²-12000m | 4mm²-830kgs | 1.12x1.12x1.12 | 20 | 4mm²-240000m | |
6mm²-12pcs | 6mm²-12000m | 6mm²-1070kgs | 6mm²-240000m |
Have more questions?
Q: What is es-h15z-f tuv energy storage cable battery cable?
A: The es-h15z-f tuv energy storage cable battery cable is a special kind of wire that can be used for storing electricity, which meets TUV safety requirements.
Q: What does the es-h15z-f battery cable do in particular?
A: This type of battery wire has many features including being made from highly conductive copper strands wrapped in XLPO insulation rated for temperatures up to 125°C and resistant against UV rays or ozone degradation. It also has both TUV and UL certification marks on it.
Q: How does the energy storage cable insulate its material?
A: Energy Storage Cables are insulated using Cross-Linked Polyolefin (XLPO) because this material offers excellent chemical stability along with mechanical as well as thermal robustness.
Q: Can we use this product for solar power generation purposes?
A: Yes, the energy storage cable ESP15BB-K is designed specifically for solar applications due to ability work under higher than normal direct current (DC) voltages found in photovoltaic systems (PV) panels array combiner boxes etc..
Q: Where should I look if I want to buy a good quality supplier who sells these cables?
A: A good idea might be to contact manufacturers based either throughout China or within Europe – just make sure they provide genuine parts backed by certified bodies such as TUV Rheinland Group so you know what you’re getting into terms of product reliability & safety standards followed during manufacturing process itself.
Q: Which certifications does this power transmission line have?
A: The power transmission line has been certified by TUV and UL organization which ensures compliance with international safety regulations while maintaining high-quality standards throughout the production process.
Q: How does XLPO insulation affect energy storage cables’ performance level?
A:XLP insulated wires possess superior heat resistance capability when compared against other types hence making them ideal for use in demanding applications like solar power plants (SPP) or even large scale electric power systems which requires materials able to withstand high temperature conditions over long periods.
Q: Can the Es-h15Z-F cable be used outdoors?
A: Yes, the es-h15z-f cable is weatherproof and can withstand exposure to UV rays, ozone, or any other elements associated with outdoor environments so it should work well if installed correctly in such areas.
Q: What are the voltage ratings for this product?
A: The es-h15z-f energy storage cable comes with a DC rating of up to 1500V which means that it can handle heavy loads without much resistance being generated along its length thereby ensuring efficiency during power transfer process.
Q: How do I know if this cable will meet my project requirements?
A: You should carefully read through all technical specifications provided by your supplier regarding their es-h15z-f battery cables and also check whether these meet TUV standards as required for safety reasons.