H1Z2Z2-K Anti-Mouse Ants Solar Cable
EN50618 & IEC62930 Certified | Anti-Mouse Ants | 1500V DC Rated
- Conductor: Tinned copper flexible conductor of Class 5
in EN 50618 - Insulation: LSZH electron-beam cross-linked Polyolefin
- Jacket: LSZH electron-beam cross-linked Polyolefin
- Fast Sample Processing with Customized Solutions
- High-Quality Materials
- Affordable Price Options
- Global Delivery
- For better data protection, make sure that all uploads are secure
Save at least 30% on average
-
Product Description
H1Z2Z2-K Anti-Mouse Ants Solar Cable : Product Description and Specifications
This TUV-certified H1Z2Z2-K solar cable features integrated chemical protection against rodents and termites. Unlike heavy armored cables, it uses a special repellent additive in the sheath to deter pests via scent and taste. It offers 100% flexibility, lightweight handling, and easy installation without compromising durability. Perfect for solar farms and agricultural projects.
-
Advantages
H1Z2Z2-K Anti-Mouse Ants Solar Cable : Benefits and Features
- Invisible Shield: This chemical additive keeps pests away—no need for bulky metal armor.
- Stays Flexible: The cable bends easily and stays soft, not stiff like those armored versions.
- Saves Money: Lighter and less expensive than steel-armored cables. Plus, you don’t have to worry about extra grounding.
- Trusted Quality: Meets all EN 50618 and TUV standards (1500V DC).
- Built to Last: Handles UV, ozone, and rough weather for over 25 years outdoors.
H1Z2Z2-K Anti-Mouse Ants Solar Cable Specifications
| Parameter | Specification |
|---|---|
| Rated voltage | AC U0/U=1000/1000V、1500VDC |
| Voltage test on completed cable | 6.5kV AC, 15kV DC, 5min |
| Ambient temperature | -40°C up to +90°C |
| Max. temperature at conductor | +120°C |
| The expected period of use | 25 years |
| The permitted short-circuit temperature refer to a period of 5s | +200°C |
| Bending radius | ≥4xD(D<8mm), ≥6xD(D≥8mm) |
| Resistance against acid and alkaline solution | EN60811-2-1 |
| Cold bending test | EN60811-1-4 |
| Weathering/UV-resistance | HD605/A1 |
| O-zone resistance at complete cable | EN50396 |
| Flame test | IEC60332-1 |
| Smoke density | IEC61034, EN50268-2 |
| Content of halogen acid gas | IEC670754-1, EN50267-2-1 |
Dimensions/Parameters
| Nominal Conductor Cross-Section (mm²) | Conductor Structure (φ n/mm±0.015) | Conductor Stranding Outer Diameter (φ mm±0.02) | Insulation Thickness (≥ mm) | Sheath Thickness (≥ mm) | Finished Outer Diameter (φ mm±0.2) | Conductor DC Resistance (Ω/Km) | Current Carrying Capacity at 60 ℃ (A) |
|---|---|---|---|---|---|---|---|
| 1.5 | 30/0.24 | 1.5 | 0.7 | 0.8 | 4.6 | 13.7 | 30 |
| 2.5 | 49/0.24 | 1.9 | 0.7 | 0.8 | 5.0 | 8.21 | 41 |
| 4 | 56/0.28 | 2.4 | 0.7 | 0.8 | 5.55 | 5.09 | 55 |
| 6 | 84/0.28 | 3.0 | 0.7 | 0.8 | 6.15 | 3.39 | 70 |
| 10 | 142/0.285 | 3.9 | 0.7 | 0.8 | 7.1 | 1.95 | 98 |
| 16 | 126/0.39 | 5.6 | 0.7 | 0.9 | 8.6 | 1.24 | 132 |
| 25 | 189/0.39 | 6.6 | 0.9 | 1.0 | 10.4 | 0.795 | 176 |
| 35 | 276/0.39 | 8.1 | 0.9 | 1.1 | 12.1 | 0.565 | 218 |
| 50 | 396/0.39 | 9.1 | 1.0 | 1.2 | 13.6 | 0.393 | 276 |
| 2x1.5 | 30/0.24 | 1.5 | 0.7 | 0.8 | 4.6x9.5 | 13.7 | 24 |
| 2x2.5 | 49/0.24 | 1.9 | 0.7 | 0.8 | 5.0x10.5 | 8.21 | 33 |
| 2x4 | 56/0.28 | 2.4 | 0.7 | 0.8 | 5.55x11.6 | 5.09 | 44 |
| 2x6 | 84/0.28 | 3.0 | 0.7 | 0.8 | 6.15x12.9 | 3.39 | 57 |
| 2x10 | 142/0.285 | 3.9 | 0.7 | 0.8 | 7.4x15.4 | 1.95 | 79 |
-
Production Processes Of Photovoltaic Wire
The JOCA cable factory has an intelligent and digital factory which makes the entire production as well as inspection process integrated, intelligent and digital. It fails to mention that it removes errors and defects from initial manual assembly of products made by workers hence enhancing the dependability of its goods. Further, it is equipped with all necessary inspection and testing facilities that employ such techniques as digital smart image detection, laser detection etc. in order to ensure product quality during shipment.
Packing For Shipment
There are numerous packaging techniques that can be used to cater for different transportation requirements.
| Packing Pictures | Packing Method | Qty/pallet(pcs) | Meter/pallet (M) | G.W/pallet(KGS) | Pallet size (m) | Pallet/20GP | Meter/20GP |
|---|---|---|---|---|---|---|---|
![]() | 100M/ROLL | 4mm²-176pcs | 4mm²-17600m | 4mm²-1144kgs | 1.12x1.12x1.12m | 20 | 4mm²-352000m |
| 6mm²-160pcs | 6mm²-16000m | 6mm²-1360kgs | 6mm²-320000m | ||||
![]() | 200M/ROLL | 4mm²-90pcs | 4mm²-18000m | 4mm²-1170kgs | 1.12x1.12x1.12m | 20 | 4mm²-360000m |
| 6mm²-81pcs | 6mm²-16200m | 6mm²-1377kgs | 6mm²-324000m | ||||
![]() | 100m/plastic drum | 4mm²-125pcs | 4mm²-12500m | 4mm²-850kgs | 1.12x1.12x1.12m | 20 | 4mm²-250000m |
| 6mm²-100pcs | 6mm²-10000m | 6mm²-900kgs | 6mm²-200000m | ||||
![]() | 500m/wood drum | 4mm²-27pcs | 4mm²-13500m | 4mm²-1197kgs | 1.12x1.12x1.12 | 20 | 4mm²-270000m |
| 6mm²-27pcs | 6mm²-13500m | 6mm²-930kgs | 6mm²-270000m | ||||
![]() | 1000M/wood drum | 4mm²-12pcs | 4mm²-12000m | 4mm²-830kgs | 1.12x1.12x1.12 | 20 | 4mm²-240000m |
| 6mm²-12pcs | 6mm²-12000m | 6mm²-1070kgs | 6mm²-240000m |
Have more questions?
Q: How does it stop rats?
A: A chemical additive creates a repulsive taste and scent that stops them from chewing.
Q: Will the chemical additive affect the conductivity or performance of the cable?
A: Not at all. The additive only goes into the insulation and sheath, not anywhere near the copper inside. It doesn’t change how the cable works—no impact on electrical properties, resistance, or voltage rating.
Q: Is this cable as flexible as a standard solar cable?
A: Yes, it bends and handles just like any regular H1Z2Z2-K PV wire. There’s no bulky steel tape or armor inside, so you get the same flexibility, diameter, and weight. It’s easy to work with and install.
Q:How long does the anti-Mouse Ants effect last?
A: The chemical additive is stable and integrated into the material structure. It is designed to remain effective throughout the expected lifespan of the solar cable (25+ years), providing long-term protection.
Q: Is it safe for the environment?
A: Yes, it is RoHS/REACH compliant and safe for soil and humans.
Q: What certification does it have?
A: It is TUV certified according to the EN 50618 (H1Z2Z2-K) standard.
Q: Can I use this cable for direct burial underground?
A: While the cable is resistant to termites and moisture, for direct burial, we generally recommend laying it within a conduit or sand bed to prevent physical damage from sharp rocks. However, its termite resistance makes it far superior to standard cables for underground use in pest-prone areas.
Q : Why choose this over armored cable?
A: It is lighter, faster to install, and does not require expensive earthing work.