600 volt secondary Type URD cable -aluminum conductor

Single Duplex Triplex and Quaplex Cables for secondary power distribution

Construction:

  • Conductors: Class B compressed stranded Aluminum (1350-H19 or AA-8000 series) per ASTM B231/B800/B801.

  • Insulation: Black Thermoset Cross-linked Polyethylene (XLPE).

Applicable Standards:

  • ICEA S-105-692: 600V Single layer thermoset insulated utility underground distribution cable.

  • UL 854: Service Entrance Cables.

 Save at least 30% on average

  • icon

    Product Description

    Secondary URD Cable: Product Description and Specifications

Engineered for 600V underground residential distribution, this Secondary URD specification utilizes concentric stranded or compressed 1350-H19 aluminum conductors. The assembly relies on a ruggedized XLPE dielectric system, selected explicitly to block moisture ingress and resist trench abrasion during direct burial or duct installation. Compliance is strictly validated against ICEA and ASTM standards for secondary network reliability, ensuring mechanical durability without requiring additional conduit protection.

Secondary URD Cable
  • icon

    Advantages

    Secondary URD Cable: Benefits and Features

  • Dielectric System: Black XLPE. Specified for high thermal stability and abrasion resistance. (No jacket required).

  • Duct Optimization: Compressed Stranding. Reduces outer diameter (OD). Engineering result: Lowers friction coefficient during duct pulling.

  • Neutral Identification: Visual Coding: Yellow Striping (or jacket) on neutral. Eliminates phasing errors during termination.

  • Metallurgy: AA-8000 Series Alloy. Selected for high conductivity-to-weight ratio and superior bend radius compared to standard 1350 aluminum.

  • Deployment Rating: 600V. Verified for Direct Burial or Raceway (Conduit) installation.

Specification Of Secondary URD Cable

SINGLE DUPLEX TRIPLEX QUADRUPLEX 600V SECONDARY URD
TypeCode NamePhase Size (AWG/kcmil)Phase StrandingPhase Insulation (mils)Neutral Size (AWG/kcmil)Neutral StrandingNeutral Insulation (mils)Single Phase Diameter (mils)Complete Cable Diameter (mils)Weight (lb/kft)Ampacity Direct BurialAmpacity Duct/ConduitNEC Ampacity 60°CNEC Ampacity 75°CNEC Ampacity 90°C
SingleCornell8760 260260347436404449
SinglePrinceton6760 300300479647465659
SingleMercer4760 3503506711760637281
SingleClemson2760 410410971548286100108
SingleKenyon11980 4904901281719798111124
SingleHarvard1/01980 520520154193112115133146
SingleYale2/01980 570570186221132132150162
SingleTufts3/01980 620620225253155150172189
SingleBeloit4/01980 680680274290185173200221
SingleHofstra2503795 750750329317199196228248
SingleGonzaga3003795 810810385349223224255281
SingleRutgers3503795 850850439381248242278302
SingleDartmouth4003795 900900493410272259300329
SingleBrown4503795 940940547439295---
SingleEmory5003795 980980601464318299344378
SingleDuke60061110 10901090725514355328377416
SingleFurman70061110 11601160830549386362416459
SingleSewanee75061110 11901190883567403368427470
SingleFordham100061110 134013401144665492431494540
DuplexBard87608760262524767055
DuplexClaflin67606760298596919570
DuplexDelgado4760476034569012912590
DuplexEverett27602760403806189187100
TriplexErskine676067602986441369570
TriplexVassar4760476034574519412590
TriplexStephens27604760403870260165120
TriplexRamapo27602760403870290165120
TriplexBrenau1/0198027605121106409215160
TriplexBergen1/019801/019805121106476215160
TriplexConverse2/01980119805551199490245180
TriplexHunter2/019802/019805551199540245180
TriplexHollins3/019801/019806031302586280205
TriplexSweetbriar4/019802/019806581421740315240
TriplexMonmouth4/019804/019806581421847315240
TriplexPratt25037953/019807321581857345265
TriplexWesleyan35037954/0198083117951135415320
TriplexRider5003795350379598021171248495395
TriplexFairfield750611105003795118828602304615525
QuadruplexTulsa4760476034583325812085
QuadruplexDyke27604760403973367155115
QuadruplexWittenberg27602760403973375155115
QuadruplexNotre Dame1/0198027605121236574200150
QuadruplexPurdue1/019801/019805121236596200150
QuadruplexSyracuse2/01980119805551340664225170
QuadruplexLafayette2/019802/019805551340720225170
QuadruplexSwarthmore3/019801/019806031456805250195
QuadruplexDavidson3/019803/019806031456874250195
QuadruplexWake Forest4/019802/0198065815881036290225
QuadruplexEarlham4/019804/0198065815881066290225
QuadruplexRust25037953/0198076018301213325210
QuadruplexSlippery Rock35037954/0198083119451544385305
QuadruplexWofford5003795350379599023902251467420
QuadruplexWindham750611105003795120028903266615492
DUPLEX TRIPLEX QUADRUPLEX 600V SECONDARY URD
CategoryCode NamePhase AWGPhase StrandingPhase Insulation ThicknessNeutral AWGNeutral StrandingNeutral Insulation ThicknessDiameter Single Phase (mils)Diameter Complete Cable (mils)Weight (lbs/kft)Ampacity Direct BurialAmpacity In Ducts
DUPLEXBard87608760262524767055
DUPLEXClafin67606760298596919570
DUPLEXDelgado4760476034569012912590
DUPLEXEverett27602760403806189187100
TRIPLEXErskine676067602986441369570
TRIPLEXVassar4760476034574519412590
TRIPLEXStephens27604760403870260165120
TRIPLEXRamapo27602760403870290165120
TRIPLEXBrenau1/0198027605121106409215160
TRIPLEXBergen1/019801/019805121106476215160
TRIPLEXConverse2/01980119805551199490245180
TRIPLEXHunter2/019802/019805551199540245180
TRIPLEXHollins3/019801/019806031302586280205
TRIPLEXSweetbriar4/019802/019806581421740315240
TRIPLEXMonmouth4/019804/019806581421847315240
TRIPLEXPratt25037953/019807321581857345265
TRIPLEXWesleyan35037954/0198083117951135415320
TRIPLEXRider5003795350379598021171248495395
TRIPLEXFairfield750611105003795118828602304615525
QUADRUPLEXTulsa4760476034583325812085
QUADRUPLEXDyke27604760403973367155115
QUADRUPLEXWittenberg27602760403973375155115
QUADRUPLEXNotre Dame1/0198027605121236574200150
QUADRUPLEXPurdue1/019801/019805121236596200150
QUADRUPLEXSyracuse2/01980119805551340664225170
QUADRUPLEXLafayette2/019802/019805551340720225170
QUADRUPLEXSwarthmore3/019801/019806031456805250195
QUADRUPLEXDavidson3/019803/019806031456874250195
QUADRUPLEXWake Forest4/019802/0198065815881036290225
QUADRUPLEXEarlham4/019804/0198065815881066290225
QUADRUPLEXRust25037953/0198076018301213325210
QUADRUPLEXSlippery Rock35037954/0198083119451544385305
QUADRUPLEXWofford5003795350379599023902251467420
QUADRUPLEXWindham750611105003795120028903266615492
600V TRI-RATED 8000 SERIES ALUMINUM URD
Code NamePhase Size (AWG/kcmil)Phase StrandingPhase Insulation Thickness (mils)Neutral Size (AWG/kcmil)Neutral StrandingNeutral Insulation Thickness (mils)Single Phase Cond. Diameter (mils)Complete Cable Diameter (mils)Weight (lb/kft)Ampacity Direct BurialAmpacity In Ducts
VASSAR-80004760476034574519112590
STEPHENS-800027604760403870246165120
RAMAPO-800027602760403870290165120
BRENAU-80001/0198027605121106389215160
BERGEN-80001/019801/019805121106476215160
CONVERSE-80002/01980119805551199483245180
HUNTER-80002/011802/011805551199545245180
SWEETBRIAR-80004/019802/019806581421715315240
MONMOUTH-80004/019804/019806581421802315240
PRATT-800025037953/019807321581867345265
WESLEYAN-800035037954/0198083117951165415320
  • icon

    Production Processes Of Aerial Bundled Cable

The aerial cable manufacturing infrastructure operates a closed-loop digital automation system, integrating conductor stranding, insulation extrusion, and final sheathing into a continuous workflow. Process stability relies on embedded sensor arrays tracking extrusion parameters in real-time, eliminating manual variances. Quality validation is enforced through specific in-line hardware, including dual-axis laser diameter gauges and high-voltage spark testers, while the physical laboratory conducts destructive tensile and elongation analysis to verify compliance with international standards before shipment.

Production Processes Of Photovoltaic Wire

Packing For Shipment

To meet various transportation needs, there are many methods of packaging that can be used.

Packing For Shipment

Have more questions?

We’ve compiled the most common questions regarding specifications, safety standards, and applications below. If you don't see what you're looking for, or have a specific custom requirement, just contact our engineering team directly.

Q: Direct Burial Capability?

A: Verified. Engineered specifically for Direct Earth Burial and Ducting (Wet or Dry soil conditions).

 

Q: Thermal Rating?

A: 90°C (Continuous Normal Operation).

 

Q: Neutral Conductor Identification?

A: Visual Coding: Marked with Yellow Striping (or Full Yellow Jacket) to prevent phasing errors.

 

Q: Alloy Specifications?

 A: Material: 1350-H19 Aluminum or AA-8000 Series Alloy (Dependent on specific configuration).

 

Q: Chemical/Moisture Resistance?

A: High Resilience. The XLPE dielectric system blocks heat, ozone, oil, and common sub-surface chemical agents.

Q: UL Certification?

A: Compliance: Single conductors are UL Listed (Type USE-2) for underground service entrance.

Q: Above-Ground Application?

A: Restricted. Primary design is for underground networks. Above-ground installation (risers) requires verification of local code/sunlight resistance ratings.

 

Q: How to Request Pricing/Specs?

A: Action: Click the “Contact Us” button or view the Seller Profile directly for official quotations.

Scroll to Top
Get in touch with JOCA company

Kindly complete the form below to reach out to us. We aim to get back to you within 12 hours. Wishing you the very best!

Contact Form Demo

JOCA